Literature DB >> 17459605

Intensity-modulated radiotherapy using implanted fiducial markers with daily portal imaging: assessment of prostate organ motion.

Jergin Chen1, R Jeffrey Lee, Diana Handrahan, William T Sause.   

Abstract

PURPOSE: To assess our single institutional experience with daily localization, using fiducials for prostate radiotherapy. METHODS AND MATERIALS: From January 2004 to September 2005, 33 patients were treated with 1,097 intensity-modulated radiation treatments, using three implanted fiducials. Daily portal images were obtained before treatments. Shifts were made for deviations > or =3 mm in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) dimensions.
RESULTS: Of 1,097 treatments, 987 (90%) required shifts. Shifts were made in the LR, SI, and AP dimensions in 51%, 67%, and 58% of treatments, respectively. In the LR dimension, the median distance shifted was 5 mm. Of 739 shifts in the SI dimension, 73% were in the superior direction for a median distance of 6 mm, and 27% were shifted inferiorly for a median distance of 5 mm. The majority of shifts in the AP dimension were in the anterior direction (87%). Median distances shifted in the anterior and posterior directions were 5 mm and 4 mm, respectively. The median percentage of treatments requiring shifts per patient was 93% (range, 57-100%). Median deviations in the LR, SI, and AP dimensions were 3 mm, 4 mm, and 3 mm, respectively. Deviations in the SI and AP dimensions were more often in the superior rather than inferior (60% vs. 29%) and in the anterior rather than posterior (70% vs. 16%) directions.
CONCLUSIONS: Interfraction prostate motion is significant. Daily portal imaging with implanted fiducials improves localization of the prostate, and is necessary for the reduction of treatment margins.

Entities:  

Mesh:

Year:  2007        PMID: 17459605     DOI: 10.1016/j.ijrobp.2007.02.024

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  18 in total

1.  Phantom measurements to quantify the accuracy of a commercially available cone-beam CT gray-value matching algorithm using multiple Fiducials.

Authors:  Frederick Marc Köhler; Judit Boda-Heggemann; Beate Küpper; Dirk Wolff; Hansjörg Wertz; Frank Lohr; Frederik Wenz
Journal:  Strahlenther Onkol       Date:  2009-02-18       Impact factor: 3.621

2.  Intrafractional motion of the prostate during hypofractionated radiotherapy.

Authors:  Yaoqin Xie; David Djajaputra; Christopher R King; Sabbir Hossain; Lijun Ma; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-09-01       Impact factor: 7.038

Review 3.  Fiducial marker guided prostate radiotherapy: a review.

Authors:  Angela G M O'Neill; Suneil Jain; Alan R Hounsell; Joe M O'Sullivan
Journal:  Br J Radiol       Date:  2016-09-23       Impact factor: 3.039

4.  The dosimetric impact of prostate rotations during electromagnetically guided external-beam radiation therapy.

Authors:  Hanan Amro; Daniel A Hamstra; Daniel L Mcshan; Howard Sandler; Karen Vineberg; Scott Hadley; Dale Litzenberg
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-05-02       Impact factor: 7.038

5.  Image-guided radiotherapy of the prostate using daily CBCT: the feasibility and likely benefit of implementing a margin reduction.

Authors:  I F Maund; R J Benson; J Fairfoul; J Cook; R Huddart; A Poynter
Journal:  Br J Radiol       Date:  2014-10-29       Impact factor: 3.039

6.  Practical method of adaptive radiotherapy for prostate cancer using real-time electromagnetic tracking.

Authors:  Jeffrey R Olsen; Camille E Noel; Kenneth Baker; Lakshmi Santanam; Jeff M Michalski; Parag J Parikh
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-04-04       Impact factor: 7.038

7.  Is a 3-mm intrafractional margin sufficient for daily image-guided intensity-modulated radiation therapy of prostate cancer?

Authors:  Adam D Melancon; Jennifer C O'Daniel; Lifei Zhang; Rajat J Kudchadker; Deborah A Kuban; Andrew K Lee; Rex M Cheung; Renaud de Crevoisier; Susan L Tucker; Wayne D Newhauser; Radhe Mohan; Lei Dong
Journal:  Radiother Oncol       Date:  2007-09-24       Impact factor: 6.280

8.  Clinical evaluation of positioning verification using digital tomosynthesis and bony anatomy and soft tissues for prostate image-guided radiotherapy.

Authors:  Sua Yoo; Q Jackie Wu; Devon Godfrey; Hui Yan; Lei Ren; Shiva Das; William R Lee; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-01-01       Impact factor: 7.038

9.  Schedule for CT image guidance in treating prostate cancer with helical tomotherapy.

Authors:  G Beldjoudi; S Yartsev; G Bauman; J Battista; J Van Dyk
Journal:  Br J Radiol       Date:  2009-06-08       Impact factor: 3.039

10.  Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins.

Authors:  Volker Rudat; Mohamed Hammoud; Yogin Pillay; Abdul Aziz Alaradi; Adel Mohamed; Saleh Altuwaijri
Journal:  Radiat Oncol       Date:  2011-08-24       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.