Literature DB >> 17457884

Self-calibrated GRAPPA method for 2D and 3D radial data.

Arjun Arunachalam1, Alexey Samsonov, Walter F Block.   

Abstract

A fast parallel MRI (pMRI) reconstruction method is presented for 2D and 3D radial trajectories. A limitation of the radial generalized autocalibrating partially parallel acquisitions (GRAPPA) method is the need to acquire training data prior to the actual scan. This can be eliminated by the use of self-calibration when synthesizing the missing data for each coil reconstruction. The training data for each coil are estimated by multiplying the conventionally reconstructed composite image, which contains the aliasing artifacts from undersampling, with each coil's spatial sensitivity profile. An estimate of the individual receiver spatial sensitivity profiles is obtained from the k-space data that fulfill the Nyquist sampling criterion. The frequency domain representation of the training data is then calculated at the acquired k-space sample points and at the unacquired locations at which we desire to synthesize k-space data. Fitting the acquired k-space samples to the unacquired points creates reconstruction weights that are used to synthesize unacquired radial lines. The in vivo feasibility of the method for 2D radial trajectories is illustrated with an example of 2D abdominal imaging. Preliminary results obtained after applying the method on a 3D radial steady-state free precession (SSFP) data set are also demonstrated. (c) 2007 Wiley-Liss, Inc.

Mesh:

Year:  2007        PMID: 17457884     DOI: 10.1002/mrm.21223

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

Review 1.  Real-time magnetic resonance imaging of cardiac function and flow-recent progress.

Authors:  Shuo Zhang; Arun A Joseph; Dirk Voit; Sebastian Schaetz; Klaus-Dietmar Merboldt; Christina Unterberg-Buchwald; Anja Hennemuth; Joachim Lotz; Jens Frahm
Journal:  Quant Imaging Med Surg       Date:  2014-10

2.  A radial self-calibrated (RASCAL) generalized autocalibrating partially parallel acquisition (GRAPPA) method using weight interpolation.

Authors:  Noel C F Codella; Pascal Spincemaille; Martin Prince; Yi Wang
Journal:  NMR Biomed       Date:  2010-12-28       Impact factor: 4.044

3.  Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging.

Authors:  Nicole Seiberlich; Philipp Ehses; Jeff Duerk; Robert Gilkeson; Mark Griswold
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

4.  Robust GRAPPA reconstruction and its evaluation with the perceptual difference model.

Authors:  Donglai Huo; David L Wilson
Journal:  J Magn Reson Imaging       Date:  2008-06       Impact factor: 4.813

Review 5.  Non-Cartesian parallel imaging reconstruction.

Authors:  Katherine L Wright; Jesse I Hamilton; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-10       Impact factor: 4.813

6.  Error decomposition for parallel imaging reconstruction using modulation-domain representation of undersampled data.

Authors:  Yu Li
Journal:  Quant Imaging Med Surg       Date:  2014-04

7.  Three-dimensional through-time radial GRAPPA for renal MR angiography.

Authors:  Katherine L Wright; Gregory R Lee; Philipp Ehses; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-21       Impact factor: 4.813

8.  Variable-density parallel imaging with partially localized coil sensitivities.

Authors:  Tolga Cukur; Juan M Santos; John M Pauly; Dwight G Nishimura
Journal:  IEEE Trans Med Imaging       Date:  2010-03-15       Impact factor: 10.048

9.  Accelerated whole-heart coronary MRA using motion-corrected sensitivity encoding with three-dimensional projection reconstruction.

Authors:  Jianing Pang; Behzad Sharif; Reza Arsanjani; Xiaoming Bi; Zhaoyang Fan; Qi Yang; Kuncheng Li; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

10.  Data consistency criterion for selecting parameters for k-space-based reconstruction in parallel imaging.

Authors:  Roger Nana; Xiaoping Hu
Journal:  Magn Reson Imaging       Date:  2009-06-30       Impact factor: 2.546

View more