Literature DB >> 17457865

Carotid plaque classification: defining the certainty with which plaque components can be differentiated.

Raphael R Ronen1, Sharon E Clarke, Robert R Hammond, Brian K Rutt.   

Abstract

Multicontrast-weighted MRI has the potential to become a powerful tool for assessment of atherosclerotic plaque. However, similarities in MR properties across plaque components limit the certainty with which these components can be differentiated. An understanding of MRI's underlying limitations in distinguishing atherosclerotic plaque components, and optimization of key parameters (including the set of components investigated and contrast weightings used) are required. In this study we analyzed endarterectomy specimens using multicontrast MRI and compared the results with matching histological findings to determine the probability of error, an unbiased measure of the underlying error caused by similarity in the spectral characteristics of components. The total error was >40% when five distinct components were investigated, but this was halved when components with similar functions and intensities were grouped together. When three contrast weightings were used to view plaque, diffusion-weighted imaging (DWI) proved valuable for separating hemorrhage from necrotic core, and "hemorrhage + necrotic" from "loose connective tissue + fibrous tissue." A two-way interaction between contrast weightings and components demonstrated that the value of a contrast can be exploited or marginalized depending on the choice of contrast weightings used. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17457865     DOI: 10.1002/mrm.21214

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

1.  Segmentation of carotid plaque using multicontrast 3D gradient echo MRI.

Authors:  Wenbo Liu; Niranjan Balu; Jie Sun; Xihai Zhao; Huijun Chen; Chun Yuan; Huilin Zhao; Jianrong Xu; Guangzhi Wang; William S Kerwin
Journal:  J Magn Reson Imaging       Date:  2011-11-29       Impact factor: 4.813

2.  Simultaneous bilateral magnetic resonance imaging of the femoral arteries in peripheral arterial disease patients.

Authors:  Ryan Brown; Christof Karmonik; Gerd Brunner; Alan Lumsden; Christie Ballantyne; Shawna Johnson; Yi Wang; Joel Morrisett
Journal:  J Magn Reson Imaging       Date:  2011-05-19       Impact factor: 4.813

3.  Signal features of the atherosclerotic plaque at 3.0 Tesla versus 1.5 Tesla: impact on automatic classification.

Authors:  William S Kerwin; Fei Liu; Vasily Yarnykh; Hunter Underhill; Minako Oikawa; Wei Yu; Thomas S Hatsukami; Chun Yuan
Journal:  J Magn Reson Imaging       Date:  2008-10       Impact factor: 4.813

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.