Literature DB >> 17455833

Theoretical comparison of aberration-correcting customized and aspheric intraocular lenses.

Patricia A Piers1, Henk A Weeber, Pablo Artal, Sverker Norrby.   

Abstract

PURPOSE: To assess the performance and optical limitations of standard, aspheric, and wavefront-customized intraocular lenses (IOLs) using clinically verified pseudophakic eye models.
METHODS: White light pseudophakic eye models were constructed from physical measurements performed on 46 individual cataract patients and subsequently verified using the clinically measured contrast sensitivity function (CSF) and wavefront aberration of pseudophakic patients implanted with two different types of IOLs. These models are then used to design IOLs that correct the astigmatism and higher order aberrations of each individual eye model's cornea and to investigate how this correction would affect visual benefit, subjective tolerance to lens misalignment (tilt, decentration, and rotation), and depth of field.
RESULTS: Physiological eye models and clinical outcomes show similar levels of higher order aberration and contrast improvement. Customized correction of ocular wavefront aberrations with an IOL results in contrast improvements on the order of 200% over the control and the Tecnis IOLs. The customized lenses can be, on average, decentered by as much as 0.8 mm, tilted > 10 degrees , and rotated as much as 15 degrees before their polychromatic modulation transfer function at 8 cycles/degree is less than that of the Tecnis or spherical control lens. Correction of wavefront aberration results in a narrower through focus curve but better out of focus performance for +/- 0.50 diopters.
CONCLUSIONS: The use of realistic eye models that include higher order aberrations and chromatic aberrations are important when determining the impact of new IOL designs. Customized IOLs show the potential to improve visual performance.

Entities:  

Mesh:

Year:  2007        PMID: 17455833     DOI: 10.3928/1081-597X-20070401-10

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  19 in total

1.  [Investigation of the theoretical image quality of aspheric intraocular lenses by decentration. Hoya AF-1 iMics1 und Zeiss ASPHINA(TM) (Invent ZO)].

Authors:  M Gillner; A Langenbucher; T Eppig
Journal:  Ophthalmologe       Date:  2012-03       Impact factor: 1.059

2.  [Clinical results of the aspheric intraocular lens FY-60AD (Hoya) with particular respect to decentration and tilt].

Authors:  U Mester; S Heinen; H Kaymak
Journal:  Ophthalmologe       Date:  2010-09       Impact factor: 1.059

3.  Comparison of contrast sensitivity, depth of field and ocular wavefront aberrations in eyes with an IOL with zero versus positive spherical aberration.

Authors:  Jay S Pepose; Mujtaba A Qazi; Keith H Edwards; Jeff P Sanderson; Edwin J Sarver
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-03-11       Impact factor: 3.117

4.  Visual impact of Zernike and Seidel forms of monochromatic aberrations.

Authors:  Xu Cheng; Arthur Bradley; Sowmya Ravikumar; Larry N Thibos
Journal:  Optom Vis Sci       Date:  2010-05       Impact factor: 1.973

5.  Visual performance after correcting higher order aberrations in keratoconic eyes.

Authors:  Ramkumar Sabesan; Geunyoung Yoon
Journal:  J Vis       Date:  2009-05-13       Impact factor: 2.240

6.  Effects of tilt and decentration of Visian Implantable Collamer Lens (ICL V4c) on visual quality: an observational study.

Authors:  Lingling Niu; Zhe Zhang; Huamao Miao; Jing Zhao; Meiyan Li; Ji C He; Peijun Yao; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2022-07-05       Impact factor: 2.086

7.  Toric markers-assisted implantation of the scleral-fixated intraocular lens.

Authors:  Hu-Ping Song; Bing-Yu Tian; Jing Peng
Journal:  Int J Ophthalmol       Date:  2016-09-18       Impact factor: 1.779

8.  Tilt and decentration of an intraocular lens implanted in the ciliary sulcus after capsular bag defect during cataract surgery.

Authors:  Thomas Sauer; Ulrich Mester
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-09-02       Impact factor: 3.117

9.  Stability of Various Types of Aspheric Intraocular Lenses After Implantation: A One-Year Retrospective Study.

Authors:  Yuan Ning; Yushuang Shao; Jiangyue Zhao; Jinsong Zhang; Mingwu Wang; Yu Qin
Journal:  Int J Gen Med       Date:  2021-06-01

10.  Comparison of retinal image quality with spherical and customized aspheric intraocular lenses.

Authors:  Huanqing Guo; Alexander V Goncharov; Chris Dainty
Journal:  Biomed Opt Express       Date:  2012-03-01       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.