Literature DB >> 17448063

Performance of six types of oxygen delivery devices at varying respiratory rates.

T A J Wagstaff1, N Soni.   

Abstract

The administration of a known concentration of oxygen is an important part of routine care of the sick patient. Many devices are currently available. The actual concentration of oxygen that can be delivered by these devices can be affected by several factors, both from the patient as well as the device itself. Measuring the F(i)o(2) delivered to the lungs in vivo can be both difficult and potentially uncomfortable for the subjects. We constructed a model using a resuscitation manikin, a ventilator and a set of bellows to simulate ventilation. With this model we tested a series of devices - variable performance, fixed performance and high flow - at two fixed tidal volumes. The respiratory rate was increased and its effect on the oxygen concentration assessed. Variable performance systems such as the Hudson mask deliver a significantly reduced oxygen concentration at high respiratory rates. Fixed performance systems delivering 24-40% oxygen deliver appropriate oxygen concentrations across the range of respiratory rates, whereas those delivering 60% show a reduction in performance. High flow systems show no failure of performance at increased respiratory rates.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17448063     DOI: 10.1111/j.1365-2044.2007.05026.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  28 in total

Review 1.  Use of high flow nasal cannula in critically ill infants, children, and adults: a critical review of the literature.

Authors:  Jan Hau Lee; Kyle J Rehder; Lee Williford; Ira M Cheifetz; David A Turner
Journal:  Intensive Care Med       Date:  2012-11-10       Impact factor: 17.440

Review 2.  Use of high-flow nasal cannula oxygenation in ICU adults: a narrative review.

Authors:  Laurent Papazian; Amanda Corley; Dean Hess; John F Fraser; Jean-Pierre Frat; Christophe Guitton; Samir Jaber; Salvatore M Maggiore; Stefano Nava; Jordi Rello; Jean-Damien Ricard; François Stephan; Rocco Trisolini; Elie Azoulay
Journal:  Intensive Care Med       Date:  2016-03-11       Impact factor: 17.440

3.  Efficiency of oxygen delivery through different oxygen entrainment devices during sedation under low oxygen flow rate: a bench study.

Authors:  Wei-Chih Hsu; Joe Orr; Shih-Pin Lin; Lu Yu; Mei-Yung Tsou; Dwayne R Westenskow; Chien-Kun Ting
Journal:  J Clin Monit Comput       Date:  2017-05-02       Impact factor: 2.502

4.  Fraction of Inspired Oxygen With Low-Flow Versus High-Flow Devices: A Simulation Study.

Authors:  Yuki Kojima; Ryozo Sendo; Naoko Okayama; Junichiro Hamasaki
Journal:  Cureus       Date:  2022-05-18

5.  Effects of high-flow oxygen therapy on patients with hypoxemia after extubation and predictors of reintubation: a retrospective study based on the MIMIC-IV database.

Authors:  Taotao Liu; Qinyu Zhao; Bin Du
Journal:  BMC Pulm Med       Date:  2021-05-13       Impact factor: 3.317

6.  Association Between Hyperoxia, Supplemental Oxygen, and Mortality in Critically Injured Patients.

Authors:  David J Douin; Erin L Anderson; Layne Dylla; John D Rice; Conner L Jackson; Franklin L Wright; Vikhyat S Bebarta; Steven G Schauer; Adit A Ginde
Journal:  Crit Care Explor       Date:  2021-05-14

7.  Extravascular lung water index improves the diagnostic accuracy of lung injury in patients with shock.

Authors:  Michelle S Chew; Lilian Ihrman; Joachim During; Lill Bergenzaun; Anders Ersson; Johan Undén; Jörgen Ryden; Eva Åkerman; Marina Larsson
Journal:  Crit Care       Date:  2012-01-03       Impact factor: 9.097

8.  Effects of wearing surgical masks on fraction of inspired oxygen in spontaneously breathing patients: improving safety for frontline healthcare professionals under pandemic situations.

Authors:  Kazuhiro Minoguchi; Akira Isii; Toshiki Nakamura; Hitoshi Sato; Takeru Abe; Hiromasa Kawakami; Kyota Nakamura; Takahisa Goto
Journal:  BMC Anesthesiol       Date:  2022-04-18       Impact factor: 2.376

9.  Impact of gas delivery systems on imaging studies of human cerebral blood flow.

Authors:  John R Cain; Laura M Parkes; Peter Eadsforth; Susan C Beards; Alan Jackson
Journal:  Radiol Res Pract       Date:  2013-12-11

10.  Nasal high-flow oxygen therapy in patients with hypoxic respiratory failure: effect on functional and subjective respiratory parameters compared to conventional oxygen therapy and non-invasive ventilation (NIV).

Authors:  Norbert Schwabbauer; Björn Berg; Gunnar Blumenstock; Michael Haap; Jürgen Hetzel; Reimer Riessen
Journal:  BMC Anesthesiol       Date:  2014-08-07       Impact factor: 2.217

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.