Literature DB >> 28466203

Efficiency of oxygen delivery through different oxygen entrainment devices during sedation under low oxygen flow rate: a bench study.

Wei-Chih Hsu1,2, Joe Orr3, Shih-Pin Lin1,4, Lu Yu5, Mei-Yung Tsou1,4, Dwayne R Westenskow3, Chien-Kun Ting6,7.   

Abstract

Sedative anesthetic procedures outside the operating room may depend on cylinders as oxygen source. Cylinders have limited storage capacity and a low oxygen flow rate improves the durability. We conducted the bench study to evaluate the fraction of inspired oxygen (FiO2) in different oxygen entrainment devices under low oxygen flow rate. The purpose of the bench study was to provide information to choose appropriate oxygen entrainment devices in non-operating room sedative anesthetic procedures. We utilized a manikin head-test lung-ventilator model and evaluated eight oxygen entrainment devices, including four nasal cannulas, two oral bite blocks, and two masks. Two different minute volumes that defined as the normal ventilation and the hypoventilation group were evaluated. Three pneuflow resistors were placed in turn in the mouth represented ratio of the nasal/oral breathing. Each condition was sampled 70 times after a 3 min ventilation period. Most devices had few drop in FiO2 according to the increased oral breathing ratio in normal ventilation. Most devices had obvious drop in FiO2 related to the increased oral breathing ratio in hypoventilation. Oxygen reservoir units had little effect for accumulating oxygen in normal ventilation. In the hypoventilation group, oxygen reservoir units helped oxygen retention in local area and maintained a higher oxygen concentration. There were multiple factors lead to different oxygen fraction that we measured, such as different devices, respiratory patterns, and oxygen reservoir units. The result of our bench study provided some information for anesthesiologist to choose appropriate oxygen entrainment devices in various sedative anesthetic procedures.

Entities:  

Keywords:  Low oxygen flow rate; Manikin head-test lung-ventilator model; Oxygen entrainment devices; Sedative anesthetic procedures

Mesh:

Substances:

Year:  2017        PMID: 28466203     DOI: 10.1007/s10877-017-0023-1

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  17 in total

1.  Dynamic dead space in face masks used with noninvasive ventilators: a lung model study.

Authors:  E Saatci; D M Miller; I M Stell; K C Lee; J Moxham
Journal:  Eur Respir J       Date:  2004-01       Impact factor: 16.671

2.  Moderate sedation for elective upper endoscopy with balanced propofol versus fentanyl and midazolam alone: a randomized clinical trial.

Authors:  B E Levitzky; R Lopez; J A Dumot; J J Vargo
Journal:  Endoscopy       Date:  2011-11-08       Impact factor: 10.093

Review 3.  Oxygen therapy: important considerations.

Authors:  S K Jindal
Journal:  Indian J Chest Dis Allied Sci       Date:  2008 Jan-Mar

4.  Measurement of intratracheal oxygen concentrations during face mask administration of oxygen: a modification for improved control.

Authors:  H R Wexler; A Aberman; A A Scott; J D Cooper
Journal:  Can Anaesth Soc J       Date:  1975-07

5.  Endoscopic sedation in the United States: results from a nationwide survey.

Authors:  Lawrence B Cohen; Julie S Wecsler; John N Gaetano; Ariel A Benson; Kenneth M Miller; Valerie Durkalski; James Aisenberg
Journal:  Am J Gastroenterol       Date:  2006-05       Impact factor: 10.864

6.  Performance of an oxygen delivery device for weaning potentially infectious critically ill patients.

Authors:  C Y So; C D Gomersall; P T Chui; M T V Chan
Journal:  Anaesthesia       Date:  2004-07       Impact factor: 6.955

7.  Evaluation of five oxygen delivery devices in spontaneously breathing subjects by oxygraphy.

Authors:  T Waldau; V H Larsen; J Bonde
Journal:  Anaesthesia       Date:  1998-03       Impact factor: 6.955

Review 8.  Endoscopist-directed administration of propofol: a worldwide safety experience.

Authors:  Douglas K Rex; Viju P Deenadayalu; Emely Eid; Thomas F Imperiale; John A Walker; Kuldip Sandhu; Anthony C Clarke; Lybus C Hillman; Akira Horiuchi; Lawrence B Cohen; Ludwig T Heuss; Shajan Peter; Christoph Beglinger; James A Sinnott; Thomas Welton; Magdy Rofail; Iyad Subei; Rodger Sleven; Paul Jordan; John Goff; Patrick D Gerstenberger; Harold Munnings; Martin Tagle; Brian W Sipe; Till Wehrmann; Jack A Di Palma; Kaitlin E Occhipinti; Egidio Barbi; Andrea Riphaus; Stephen T Amann; Gen Tohda; Timothy McClellan; Charles Thueson; John Morse; Nizam Meah
Journal:  Gastroenterology       Date:  2009-06-21       Impact factor: 22.682

9.  Outpatient endoscopic retrograde cholangiopancreatography: Safety and efficacy of anesthetic management with a natural airway in 653 consecutive procedures.

Authors:  Basavana G Goudra; Preet Mohinder Singh; Ashish C Sinha
Journal:  Saudi J Anaesth       Date:  2013-07

10.  Goudra ventilating bite block to reduce hypoxemia during endoscopic retrograde cholangiopancreatography.

Authors:  Basavana Gouda Goudra; Ms Chandramouli; Preet Mohinder Singh; Veerendra Sandur
Journal:  Saudi J Anaesth       Date:  2014-04
View more
  1 in total

1.  Fraction of Inspired Oxygen With Low-Flow Versus High-Flow Devices: A Simulation Study.

Authors:  Yuki Kojima; Ryozo Sendo; Naoko Okayama; Junichiro Hamasaki
Journal:  Cureus       Date:  2022-05-18
  1 in total