Magnetic resonance imaging technology in transtibial socket research: a pilot study.

Arjan W P Buis1, Barrie Condon, Dave Brennan, Brendan McHugh, Donald Hadley.   

Abstract

Investigations into the shape and volume of transtibial prosthetic sockets are complicated because of the difficulty in establishing an accurate reference grid. Magnetic resonance imaging (MRI) presents a possible solution to this problem. However, the reliability of MRI in defining the residual-limb/cast interface depends on the scanned image not being distorted by the materials present. We investigated the potential of MRI technology to establish the desired reference grid. Distortion from the so-called "chemical shift" may influence the MRI when certain materials are used during the casting process. These materials include plaster of paris (POP) and silicone (in the form of an interface liner). POP is commonly used to capture the shape of the residual limb. However, if the casting technique requires the use of a silicone liner, the liner is placed over the residual limb first and then the POP is applied over the liner. Experimental results indicate that the materials used do not distort or interfere with the scanned image. The object segmentation process that extracts the bone and skin from an MRI scan and enables the establishment of the required reference grid was explored. Results show that extracting the bone structure and using it as the reference grid to quantify the differences in volume and shape of the soft tissues of the residual limb is feasible.

Entities:  

Mesh:

Year:  2006        PMID: 17436174     DOI: 10.1682/jrrd.2005.08.0145

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  5 in total

Review 1.  Residual limb volume change: systematic review of measurement and management.

Authors:  Joan E Sanders; Stefania Fatone
Journal:  J Rehabil Res Dev       Date:  2011

Review 2.  Multimodality Imaging Approaches for Evaluating Traumatic Extremity Injuries: Implications for Military Medicine.

Authors:  Mitchel R Stacy; Christopher L Dearth
Journal:  Adv Wound Care (New Rochelle)       Date:  2017-07-01       Impact factor: 4.730

3.  Accuracy verification of magnetic resonance imaging (MRI) technology for lower-limb prosthetic research: utilising animal soft tissue specimen and common socket casting materials.

Authors:  Mohammad Reza Safari; Philip Rowe; Arjan Buis
Journal:  ScientificWorldJournal       Date:  2012-04-24

4.  Hands-off and hands-on casting consistency of amputee below knee sockets using magnetic resonance imaging.

Authors:  Mohammad Reza Safari; Philip Rowe; Angus McFadyen; Arjan Buis
Journal:  ScientificWorldJournal       Date:  2013-11-19

5.  Validity and reliability of a novel 3D scanner for assessment of the shape and volume of amputees' residual limb models.

Authors:  Elena Seminati; David Canepa Talamas; Matthew Young; Martin Twiste; Vimal Dhokia; James L J Bilzon
Journal:  PLoS One       Date:  2017-09-08       Impact factor: 3.240

  5 in total