Literature DB >> 17435684

Position of myopic iris-claw phakic intraocular lens by Scheimpflug photography and ultrasound biomicroscopy.

A-Y Yu1, Z-D Lin, X-Q Chen, X-Y Cai, Y-Z Liu, S-K Luo.   

Abstract

PURPOSE: To evaluate the position of iris-claw phakic intraocular lens (ICPIOL) in highly myopic eyes by Scheimpflug photography (SP) and ultrasound biomicroscopy (UBM).
METHODS: Nine eyes of five patients aged 31+/-10 years with average spherical equivalent of -16.04+/-5.46 D (range -7.88 to - 22.88 D) were enrolled in this prospective study and implanted with Verisyse ICPIOLs (AMO). The anterior segment was evaluated by SP and UBM preoperatively and for at least 1 month postoperatively. The statistical significance may be questionable due to the limited number (nine) of eyes.
RESULTS: By SP and UBM, the distance between corneal endothelium and lens (anterior chamber depth) preoperatively was 3.10+/-0.14 and 3.07+/-0.11 mm, respectively; between ICPIOL and corneal endothelium (pseudo-anterior chamber depth), 1.88+/-0.09 and 1.99+/-0.12 mm, respectively; between lens and posterior surface of ICPIOL (IL), 0.76+/-0.13 and 0.67+/-0.06 mm, respectively; between superior optic edge and iris (SOEI), 0.23+/-0.23 and 0.58+/-0.24 mm, respectively; between inferior optic edge and iris (IOEI), 0.07+/-0.13 and 0.41+/-0.22 mm, respectively; between ICPIOL haptics and the angle of anterior chamber (HA), 0.90+/-0.17 and 1.45+/-0.13 mm, respectively. ACD was well correlated between the two methods, but PACD, IL, OEI, HA were not. The postoperative measures, except IL, were significantly different between the two methods.
CONCLUSION: The differences between measurements by SP and UBM reveal the ICPIOL's position variations with change of body position. Nevertheless, it seems adequate that space is maintained between ICPIOL and corneal endothelium, angle, and crystalline lens. The ICPIOL implanted in phakic eyes seems a safe alternative for treatment of high myopia.

Entities:  

Mesh:

Year:  2007        PMID: 17435684     DOI: 10.1038/sj.eye.6702829

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  7 in total

1.  Ultrasonography of the Anterior Segment.

Authors:  Martin Heur; Bennie H Jeng
Journal:  Ultrasound Clin       Date:  2008-04-01

Review 2.  [Scheimpflug photography for the examination of phakic intraocular lenses].

Authors:  M Baumeister
Journal:  Ophthalmologe       Date:  2014-10       Impact factor: 1.059

3.  Tilt and decentration of posterior and anterior iris-claw intraocular lenses: a pilot study using anterior segment optical coherence tomography.

Authors:  Giacomo Calzetti; Carlo Bellucci; Salvatore Antonio Tedesco; Maurizio Rossi; Stefano Gandolfi; Paolo Mora
Journal:  BMC Ophthalmol       Date:  2022-05-23       Impact factor: 2.086

4.  Evaluation of the orientation of the steepest meridian of regular astigmatism among highly myopic Egyptian patients seeking non-ablative surgical correction of the refractive error.

Authors:  Tamer Adel Refai
Journal:  Electron Physician       Date:  2015-09-16

5.  Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation.

Authors:  Ting Wan; Houfa Yin; Yi Yang; Fang Wu; Zhiyi Wu; Yabo Yang
Journal:  BMC Ophthalmol       Date:  2019-08-13       Impact factor: 2.209

6.  Optical Coherence Tomography Position Analysis of Retropupillary Iris-Fixated Intraocular Lens in Iris Tissue.

Authors:  Jana C Riedl; Michael R Bopp; Charlotte F Gross; Urs Vossmerbaeumer
Journal:  J Ophthalmol       Date:  2022-08-09       Impact factor: 1.974

7.  Using a slit lamp-mounted digital high-speed camera for dynamic observation of phakic lenses during eye movements: a pilot study.

Authors:  Martin Alexander Leitritz; Focke Ziemssen; Karl Ulrich Bartz-Schmidt; Bogomil Voykov
Journal:  Clin Ophthalmol       Date:  2014-07-18
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.