AIM: To assess the correlation of echocardiographic signs of myocardial damage to serum cardiac troponin T (cTnT) concentrations in newborn infants with perinatal asphyxia. METHODS: Electocardiograms (ECG) and echocardiograms (Echo) were obtained during the first 24 h of life from 29 asphyxiated and 30 control infants and correlated with cTnT concentrations. The echocardiographic parameters included systolic ventricular performance, preload, afterload, diastolic function, stroke volume (SV), left ventricular output (LVO), hyperechogenity of the papillary muscles and insufficiency of the atrioventricular valves. RESULTS: LVO and SV were lower but CTnT were significantly higher in asphyxiated than in control infants: 0.15 (010-0.23) vs. 0.05 (0.02-0.13), p < 0.001). Asphyxiated infants with signs of myocardial damage were associated with significantly higher cTnT than those without, 0.20 (0.11-0.28) and 0.11 (0.05-0.14 ug/L), p = 0.04. CONCLUSION: Cardiac troponin may prove to be valuable in evaluating myocardial damage in birth asphyxia. However, the degree of prematurity may complicate the assessment.
AIM: To assess the correlation of echocardiographic signs of myocardial damage to serum cardiac troponin T (cTnT) concentrations in newborn infants with perinatal asphyxia. METHODS: Electocardiograms (ECG) and echocardiograms (Echo) were obtained during the first 24 h of life from 29 asphyxiated and 30 control infants and correlated with cTnT concentrations. The echocardiographic parameters included systolic ventricular performance, preload, afterload, diastolic function, stroke volume (SV), left ventricular output (LVO), hyperechogenity of the papillary muscles and insufficiency of the atrioventricular valves. RESULTS: LVO and SV were lower but CTnT were significantly higher in asphyxiated than in control infants: 0.15 (010-0.23) vs. 0.05 (0.02-0.13), p < 0.001). Asphyxiated infants with signs of myocardial damage were associated with significantly higher cTnT than those without, 0.20 (0.11-0.28) and 0.11 (0.05-0.14 ug/L), p = 0.04. CONCLUSION: Cardiac troponin may prove to be valuable in evaluating myocardial damage in birth asphyxia. However, the degree of prematurity may complicate the assessment.
Authors: Eva Forman; Colm R Breatnach; Stephanie Ryan; Jana Semberova; Jan Miletin; Adrienne Foran; Afif El-Khuffash Journal: Pediatr Res Date: 2017-08-02 Impact factor: 3.756
Authors: P S Rajakumar; B Vishnu Bhat; M G Sridhar; J Balachander; B C Konar; P Narayanan; G Chetan Journal: Indian J Pediatr Date: 2008-12-04 Impact factor: 1.967
Authors: Po-Yin Cheung; Laila Obaid; Marwan Emara; Yann Brierley; Scott T Johnson; Grace S Chan; Laurence Jewell; Gregory Korbutt; David L Bigam Journal: Intensive Care Med Date: 2008-01-31 Impact factor: 17.440
Authors: Mustafa Kurthan Mert; Mehmet Satar; Nazan Özbarlas; Akgün Yaman; Fatma Tuncay Özgünen; Hüseyin Selim Asker; Eren Kale Çekinmez; Tamer Tetiker Journal: Pediatr Cardiol Date: 2015-08-13 Impact factor: 1.655
Authors: P S Rajakumar; B Vishnu Bhat; M G Sridhar; J Balachander; B C Konar; P Narayanan; G Chetan Journal: Indian J Pediatr Date: 2009-02-04 Impact factor: 1.967