Performance of neonatal ventilators in volume targeted ventilation mode.

Atul Sharma1, Anthony D Milner, Anne Greenough.   

Abstract

AIM: To test the hypothesis that in volume targeted ventilation modes, ventilator performance would vary according to ventilator type.
METHODS: Four neonatal ventilators: Draeger Babylog 8000 (Draeger Medical, Germany), SLE 5000 infant ventilator (SLE systems, UK), Stephanie paediatric ventilator (F. Stephan Biomedical, German) and V.I.P. Bird gold (Viasys Healthcare, USA) were assessed using a lung model. Delivered peak pressure, inflation time, mean airway pressure (MAP) and volume were measured.
RESULTS: At the same preset ventilator settings, the Stephanie and V.I.P. Bird ventilators delivered significantly lower peak pressures and tended to deliver lower MAPs than the other two ventilators. At a volume targeted ventilation level of 5 mL, the SLE and the V.I.P. Bird delivered significantly shorter inflation times. The above differences related to differences in the airway pressure waveforms delivered by the four ventilators. The V.I.P. Bird had a less variable volume delivery, but this was always significantly lower than the preset volume guarantee level but higher than the volume displayed by the ventilator.
CONCLUSION: In volume targeted ventilation modes, performance differs between neonatal ventilator types; these results may have implications for clinical practise.

Entities:  

Mesh:

Year:  2007        PMID: 17429900     DOI: 10.1111/j.1651-2227.2007.00129.x

Source DB:  PubMed          Journal:  Acta Paediatr        ISSN: 0803-5253            Impact factor:   2.299


  5 in total

1.  Adult ICU ventilators to provide neonatal ventilation: a lung simulator study.

Authors:  Andrew D Marchese; Daniel Chipman; Pedro de la Oliva; Robert M Kacmarek
Journal:  Intensive Care Med       Date:  2008-10-18       Impact factor: 17.440

2.  Respiratory support practices in infants born at term in the United Kingdom.

Authors:  Olie Chowdhury; Catherine J Wedderburn; Silke Lee; Simon Hannam; Anne Greenough
Journal:  Eur J Pediatr       Date:  2012-07-22       Impact factor: 3.183

Review 3.  What is new in ventilation strategies for the neonate?

Authors:  Anne Greenough; Atul Sharma
Journal:  Eur J Pediatr       Date:  2007-06-02       Impact factor: 3.183

4.  Continuous non-invasive monitoring of tidal volumes by measurement of tidal impedance in neonatal piglets.

Authors:  Florian Kurth; Fabienne Zinnow; Alexandra Prakapenia; Sabrina Dietl; Stefan Winkler; Sascha Ifflaender; Mario Rüdiger; Wolfram Burkhardt
Journal:  PLoS One       Date:  2011-06-07       Impact factor: 3.240

5.  Neonatal ventilatory techniques - which are best for infants born at term?

Authors:  Olie Chowdhury; Anne Greenough
Journal:  Arch Med Sci       Date:  2011-07-11       Impact factor: 3.318

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.