Literature DB >> 17429178

Effect of exposure time on curing efficiency of polymerizing units equipped with light-emitting diodes.

José R David1, Osnara M Gomes, João C Gomes, Alessandro D Loguercio, Alessandra Reis.   

Abstract

A study was conducted to evaluate the top and bottom hardness of two composites cured using polymerizing units equipped with light-emitting diodes [LED] (LEDemetron; Elipar FreeLight, Coltolux LED) and one quartz-tungsten halogen device [QTH] (Optilux 501) under different exposure times (20, 40 and 60 sec). A matrix mold 5 mm in diameter and 2 mm in depth was made to obtain five disc-shaped specimens for each experimental group. The specimens were cured by one of the light-curing units (LCUs) for 20, 40 or 60 sec, and the hardness was measured with a Vickers hardness-measuring instrument (50 g/30 sec). Data were subjected to three-way ANOVA and Tukey's test (alpha = 0.05). LED LCUs were as effective as the QTH device for curing both composites. A significant increase in the microhardness values were observed for all light LCUs when the exposure time was changed from 20 sec to 40 sec. The Z250 composite showed hardness values that were usually higher than those of the Charisma composite under similar experimental conditions. LED LCUs are as efficient for curing composites as the QTH device as long as an exposure time of 40 sec or higher is employed. An exposure time of 40 sec is required to provide composites with a uniform and high Knoop hardness when LED light-curing units are employed.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17429178     DOI: 10.2334/josnusd.49.19

Source DB:  PubMed          Journal:  J Oral Sci        ISSN: 1343-4934            Impact factor:   1.556


  15 in total

1.  Diode-pumped solid-state laser for bonding orthodontic brackets: effect of light intensity and light-curing time.

Authors:  Young-Oh Kim; Soo-Byung Park; Woo-Sung Son; Ching-Chang Ko; Franklin García-Godoy; Hyung-Il Kim; Yong Hoon Kwon
Journal:  Lasers Med Sci       Date:  2010-06-08       Impact factor: 3.161

2.  Influence of physical assessment of different light-curing units on irradiance and composite microhardness top/bottom ratio.

Authors:  Susana Morimoto; Renata Aló Maluza Zanini; Josete Barbosa Cruz Meira; Carlos Martins Agra; Fernanda Calabró Calheiros; Denis Yudi Nagase
Journal:  Odontology       Date:  2016-01-13       Impact factor: 2.634

3.  A survey of power density of light-curing units used in private dental offices in Changchun City, China.

Authors:  Xinqing Hao; Meng Luo; Jian Wu; Song Zhu
Journal:  Lasers Med Sci       Date:  2013-05-23       Impact factor: 3.161

4.  The effect of irradiation distance on microhardness of resin composites cured with different light curing units.

Authors:  Isil Cekic-Nagas; Ferhan Egilmez; Gulfem Ergun
Journal:  Eur J Dent       Date:  2010-10

5.  Influence of preheating on mechanical and surface properties of nanofilled resin composites.

Authors:  Ali-Atef Elkaffass; Radwa-Ibrahim Eltoukhy; Salwa-Abd-Elraof Elnegoly; Salah-Hassab Mahmoud
Journal:  J Clin Exp Dent       Date:  2020-05-01

6.  Influence of light curing units on failure of directcomposite restorations.

Authors:  Sameer Jadhav; Vivek Hegde; Gayatri Aher; Naylah Fajandar
Journal:  J Conserv Dent       Date:  2011-07

7.  Effects of light curing method and exposure time on mechanical properties of resin based dental materials.

Authors:  A Riza Alpöz; Fahinur Ertugrul; Dilsah Cogulu; Asli Topaloglu Ak; Metin Tanoglu; Elçin Kaya
Journal:  Eur J Dent       Date:  2008-01

8.  Evaluation of the Clinical Impact of ISO 4049 in Comparison with Miniflexural Test on Mechanical Performances of Resin Based Composite.

Authors:  Luigi Calabrese; Francesca Fabiano; Lucio Maria Bonaccorsi; Valerio Fabiano; Chiara Borsellino
Journal:  Int J Biomater       Date:  2015-02-28

Review 9.  Utilizing Light Cure Units: A Concise Narrative Review.

Authors:  Fatin A Hasanain; Hani M Nassar
Journal:  Polymers (Basel)       Date:  2021-05-15       Impact factor: 4.329

10.  Light transmittance of zirconia as a function of thickness and microhardness of resin cements under different thicknesses of zirconia.

Authors:  Isil Cekic-Nagas; Ferhan Egilmez; Gulfem Ergun; Bekir-Murat Kaya
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-03-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.