Literature DB >> 17427825

The effect of soft-start polymerization by second generation LEDs on the degree of conversion of resin composite.

L E S Soares1, P C S Liporoni, A A Martin.   

Abstract

Fourier-Transform (FT)--Raman spectroscopy was used to evaluate in vitro the degree of conversion (DC) of Charisma dental composite cured by three different light curing units (LCUs) using soft-start and normal protocols. Eighty circular blocks of resin (7 mm in diameter x 2.5 mm thick) were prepared and cured using the following sources: halogen light (Degulux soft-start, n = 20, G1-G2), low power light emitting diode (LED) with transparent polymer tip (LD13, n = 20, G3-G4) and fiber optic tip (LD13, n = 20, G5-G6) and, finally, high power LED (Radii, n = 20, G7-G8). The top and bottom surfaces of the blocks were analyzed by FT-Raman spectroscopy. The respective DCs were estimated calculating the peak height ratio of the aliphatic C=C (1640 cm(-1)) and aromatic C=C (1610 cm(-1)) Raman modes. The DC at the surfaces ranged between 50% and 60% for the top and 46% and 58% for the bottom. The halogen light and high power LED LCUs with the soft-start and normal protocols produced the highest DC values of dental composite at both surfaces (p < 0.001). Curing by low power LED in the soft-start protocol did not produce adequate DC at the depth of 2.5 mm. The type of LCU light guide tip did not present a significant statistical difference in the final DC of the dental composite (p > 0.05).

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17427825     DOI: 10.2341/06-45

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  9 in total

1.  Comparative evaluation of the degree of conversion of four different composites polymerized using ultrafast photopolymerization technique: An in vitro study.

Authors:  Sundaresan Balagopal; Nagarajan Geethapriya; Sebatni Anisha; Bahavathi Ananthan Hemasathya; James Vandana; Chandrasekaran Dhatshayani
Journal:  J Conserv Dent       Date:  2021-07-05

2.  The effect of irradiation distance on microhardness of resin composites cured with different light curing units.

Authors:  Isil Cekic-Nagas; Ferhan Egilmez; Gulfem Ergun
Journal:  Eur J Dent       Date:  2010-10

3.  Influence of extended light exposure curing times on the degree of conversion of resin-based pit and fissure sealant materials.

Authors:  Nazish Fatima
Journal:  Saudi Dent J       Date:  2014-07-10

4.  Spectroscopic and Mechanical Properties of a New Generation of Bulk Fill Composites.

Authors:  Riccardo Monterubbianesi; Giovanna Orsini; Giorgio Tosi; Carla Conti; Vito Librando; Maurizio Procaccini; Angelo Putignano
Journal:  Front Physiol       Date:  2016-12-27       Impact factor: 4.566

5.  Effect of Shade and Light Curing Mode on the Degree of Conversion of Silorane-Based and Methacrylate-Based Resin Composites.

Authors:  Mousavinasab Sm; Atai M; Salehi N; Salehi A
Journal:  J Dent Biomater       Date:  2016-12

6.  Influence of handpiece maintenance sprays on resin bonding to dentin.

Authors:  Toyotarou Sugawara; Atsushi Kameyama; Akiko Haruyama; Takumi Oishi; Nobuyuki Kukidome; Yasuaki Takase; Masatake Tsunoda
Journal:  Clin Cosmet Investig Dent       Date:  2010-03-10

7.  Evaluation of degree of conversion and hardness of dental composites photo-activated with different light guide tips.

Authors:  Marília Regalado Galvão; Sergei Godeiro Fernandes Rabelo Caldas; Vanderlei Salvador Bagnato; Alessandra Nara de Souza Rastelli; Marcelo Ferrarezi de Andrade
Journal:  Eur J Dent       Date:  2013-01

8.  Flexural strength of glass and polyethylene fiber combined with three different composites.

Authors:  F Sharafeddin; Aa Alavi; Z Talei
Journal:  J Dent (Shiraz)       Date:  2013-03

9.  Influence of Light Energy Density, Composite Type, Composite Thickness, and Postcuring Phase on Degree of Conversion of Bulk-fill Composites.

Authors:  Lipika Jain; Deepak Mehta; Naganath Meena; Ravi Gupta
Journal:  Contemp Clin Dent       Date:  2018-06
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.