Literature DB >> 17427385

Transthoracic echocardiographic measurement of patent ductus arteriosus in dogs.

Matthias Schneider1, Nicolai Hildebrandt, Tatjana Schweigl, Martin Wehner.   

Abstract

BACKGROUND: Patent ductus arteriosus (PDA) size and morphology influence the selection of the kind and the size of the embolization device used to effect shunt closure. HYPOTHESIS: That echocardiographic measurement of PDA in dogs is accurate. ANIMALS: Forty-five client-owned dogs with PDA.
METHODS: Prospective observational study. Echocardiographic and angiographic data were compared.
RESULTS: Measurement of the ductus in color Doppler echocardiography (CD-E) and 2-dimensional echocardiography (2D-E) was achieved from left parasternal views in 43 of 45 unsedated dogs (96%). In these 43 dogs, the angiographic minimal PDA diameter was 3.72 +/- 1.59 mm, and the diameter of the PDA ampulla was 8.46 +/- 3.01 mm. The CD-E minimal PDA diameter ranged from 2.3 to 9.5 mm (median, 4.0 mm). There was a significant mean difference to the angiographic measurements (1.15 +/- 0.95 mm; P < .0001). An agreement in a 1-mm range was found in 21 of 43 dogs (48%). The 2D-E minimal PDA diameter was 3.73 +/- 1.78 mm, and the mean difference to the angiographic measurements was not significant (0.00 +/- 0.72 mm; P = .98). An agreement in a 1-mm range was found in 31 of 43 dogs (72%). The 2D-E measurement of the PDA ampulla revealed a significant mean difference to the angiographic data (1.95 +/- 2.43 mm, P < .0001). An agreement in a 2-mm range was found in 21 of 43 dogs (49%). CONCLUSIONS AND CLINICAL IMPORTANCE: The 2D-E from the left cranial parasternal view is an excellent noninvasive method to estimate the PDA minimal diameter before doing catheter intervention.

Entities:  

Mesh:

Year:  2007        PMID: 17427385     DOI: 10.1892/0891-6640(2007)21[251:temopd]2.0.co;2

Source DB:  PubMed          Journal:  J Vet Intern Med        ISSN: 0891-6640            Impact factor:   3.333


  6 in total

1.  Multidetector-row computed tomography of thoracic aortic anomalies in dogs and cats: patent ductus arteriosus and vascular rings.

Authors:  Christiane R Henjes; Ingo Nolte; Patrick Wefstaedt
Journal:  BMC Vet Res       Date:  2011-09-23       Impact factor: 2.741

2.  Comparative, multidimensional imaging of patent ductus arteriosus and a proposed update to the morphology classification system for dogs.

Authors:  Kelley R Doocy; Ashley B Saunders; Sonya G Gordon; Nicholas Jeffery
Journal:  J Vet Intern Med       Date:  2018-02-20       Impact factor: 3.333

3.  Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus.

Authors:  Hua Cao; Qiang Chen; Gui Can Zhang; Liang Wan Chen; Fan Xu; Jia-Xin Zhang
Journal:  Anatol J Cardiol       Date:  2018-07       Impact factor: 1.596

4.  Anatomy, baseline characteristics, and procedural outcome of patent ductus arteriosus in German Shepherd dogs.

Authors:  Sonya Wesselowski; Ashley B Saunders; Sonya G Gordon
Journal:  J Vet Intern Med       Date:  2018-12-17       Impact factor: 3.333

5.  Transcatheter closure of patent ductus arteriosus: initial study on echocardiographic estimation of device size.

Authors:  Alimohammad Hajizeinali; Hakimeh Sadeghian; Mehrnaz Rezvanfard; Mohammad Alidoosti; Seyed Ebrahim Kassaian; Ebrahim Nematipour
Journal:  J Tehran Heart Cent       Date:  2010-09-30

6.  Low profile vascular plug for transarterial occlusion of patent ductus arteriosus in small dogs.

Authors:  Alma H Hulsman; Johannes M P J Breur; Viktor Szatmári
Journal:  J Vet Intern Med       Date:  2020-11-26       Impact factor: 3.175

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.