Literature DB >> 17418723

Distalization of maxillary molars with the bone-supported pendulum: a clinical study.

Sergio Andres Escobar1, Paola Andrea Tellez, Cesar Augusto Moncada, Carlos Alberto Villegas, Carlos Mario Latorre, Giovanni Oberti.   

Abstract

A modified pendulum appliance with 2 endosseus screws for anchorage in the palatal area was used for maxillary molar distalization in each of 15 patients (average age, 13 +/- 2.1 years). Study models and lateral and panoramic x-rays were taken at the beginning and end of the movement to record the dental and skeletal changes. The mean treatment time was 7.8 +/- 1.7 months, the average distal movement of the maxillary molars was 6 mm, and the inclination was 11.3 degrees +/- 6.2 degrees. The second premolars were distalized an average of 4.85 +/- 1.96 mm with inclinations of 8.6 degrees +/- 5 degrees. The maxillary anterior teeth were retruded 0.5 +/- 1.33 mm and palatally inclined 2.5 degrees +/- 2.98 degrees. The mandibular plane rotated posteriorly 1.27 degrees +/- 1.1 degrees. No loss of dental anchorage was observed during the distal movement.

Entities:  

Mesh:

Year:  2007        PMID: 17418723     DOI: 10.1016/j.ajodo.2006.08.012

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  15 in total

1.  Maxillary molar distalization with miniscrew-supported appliances in Class II malocclusion: A systematic review.

Authors:  Roshan Noor Mohamed; Sakeenabi Basha; Yousef Al-Thomali
Journal:  Angle Orthod       Date:  2018-04-17       Impact factor: 2.079

2.  Evaluation of the effects of the hybrid Pendulum in comparison with the conventional Pendulum appliance.

Authors:  Erdal Bozkaya; Tuba Tortop; Sema Yüksel; Emine Kaygısız
Journal:  Angle Orthod       Date:  2019-10-23       Impact factor: 2.079

3.  Treatment efficiency of mini-implant-borne distalization depending on age and second-molar eruption.

Authors:  M Nienkemper; B Wilmes; A Pauls; S Yamaguchi; B Ludwig; D Drescher
Journal:  J Orofac Orthop       Date:  2014-03-02       Impact factor: 1.938

4.  Evaluation of Dentoalveolar and Dentofacial Effects of a Mini-Screw-Anchored Pendulum Appliance in Maxillary Molar Distalization.

Authors:  Mümin Kırcalı; Alime Sema Yüksel
Journal:  Turk J Orthod       Date:  2018-12-01

5.  Effects of maxillary molar distalization with Zygoma-Gear Appliance.

Authors:  Metin Nur; Mehmet Bayram; Mevlut Celikoglu; Dogan Kilkis; Ali Alper Pampu
Journal:  Angle Orthod       Date:  2011-12-08       Impact factor: 2.079

6.  Comparison of two implant-supported molar distalization systems.

Authors:  Cagla Sar; Burcak Kaya; Omur Ozsoy; Ayca Arman Özcirpici
Journal:  Angle Orthod       Date:  2012-10-29       Impact factor: 2.079

7.  Class II correction by maxillary en masse distalization using a completely customized lingual appliance and a novel mini-screw anchorage concept - preliminary results.

Authors:  Frauke Beyling; Elisabeth Klang; Eva Niehoff; Rainer Schwestka-Polly; Hans-Joachim Helms; Dirk Wiechmann
Journal:  Head Face Med       Date:  2021-06-29       Impact factor: 2.151

8.  The use of intraosseous screw for upper molar distalization: a case report.

Authors:  Omür Polat-Ozsoy
Journal:  Eur J Dent       Date:  2008-04

9.  Comparative evaluation of molar distalization therapy using pendulum and distal screw appliances.

Authors:  Alberto Caprioglio; Alessandra Cafagna; Mattia Fontana; Mauro Cozzani
Journal:  Korean J Orthod       Date:  2015-07-24       Impact factor: 1.372

10.  Three-dimensional analysis of the distal movement of maxillary 1st molars in patients fitted with mini-implant-aided trans-palatal arches.

Authors:  Amirfarhang Miresmaeili; Ahmad Sajedi; Abbas Moghimbeigi; Nasrin Farhadian
Journal:  Korean J Orthod       Date:  2015-09-23       Impact factor: 1.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.