The effect of varying echo spacing within a multiecho acquisition: better characterization of long T2 components.

Matthew G Skinner1, Shannon H Kolind, Alex L MacKay.   

Abstract

A 48-echo pulse sequence with five different echo-spacing combinations was examined to determine how one can most effectively measure the T2 relaxation characteristics of cerebral tissue containing a long T2 component. For each scan, the first 32 echoes had an echo spacing of 10 ms, while the spacing for Echoes 33-48 (DeltaTE2) was 10, 20, 30, 40 or 50 ms. In an in vivo study using 10 normal volunteers, it was found that the resolution of T2 distribution peaks for both myelin water (approximately 20 ms) and intracellular/extracellular (IE) water (approximately 80 ms) improved as DeltaTE2 increased. The geometric mean T2 values of the main peak agreed within the error for all DeltaTE2 values. A phantom study simulated T2 relaxation distributions that are expected in the brains of patients with demyelinating diseases. For phantoms in which the T2 values of the IE and lesion (200-500 ms) water compartments were separated by at least a factor of 3, each compartment in the distribution was better resolved when DeltaTE2=40 or 50 ms. On the basis of these results, we recommend the use of extended DeltaTE2 values for imaging patients with lesions, without the risk of losing valuable short T2 information.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17418518     DOI: 10.1016/j.mri.2006.09.046

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  12 in total

1.  Diffusion time dependence of magnetic resonance diffusion signal decays: an investigation of water exchange in human brain in vivo.

Authors:  Marzieh Nezamzadeh
Journal:  MAGMA       Date:  2011-11-24       Impact factor: 2.310

2.  Exchange-mediated contrast agents for spin-lock imaging.

Authors:  Jared G Cobb; Jingping Xie; Ke Li; Daniel F Gochberg; John C Gore
Journal:  Magn Reson Med       Date:  2011-09-27       Impact factor: 4.668

3.  T1ρ mapping of pediatric epiphyseal and articular cartilage in the knee.

Authors:  Jared Guthrie Cobb; J Herman Kan; John C Gore
Journal:  J Magn Reson Imaging       Date:  2013-05-06       Impact factor: 4.813

4.  Temporal phase correction of multiple echo T2 magnetic resonance images.

Authors:  Thorarin A Bjarnason; Cornelia Laule; Joel Bluman; Piotr Kozlowski
Journal:  J Magn Reson       Date:  2013-03-16       Impact factor: 2.229

5.  Effect of intercompartmental water exchange on the apparent myelin water fraction in multiexponential T2 measurements of rat spinal cord.

Authors:  Kevin D Harkins; Adrienne N Dula; Mark D Does
Journal:  Magn Reson Med       Date:  2011-06-28       Impact factor: 4.668

6.  On the inherent precision of mcDESPOT.

Authors:  Christopher L Lankford; Mark D Does
Journal:  Magn Reson Med       Date:  2012-03-12       Impact factor: 4.668

7.  On the measurement of multi-component T2 relaxation in cartilage by MR spectroscopy and imaging.

Authors:  ShaoKuan Zheng; Yang Xia
Journal:  Magn Reson Imaging       Date:  2010-01-12       Impact factor: 2.546

8.  Characterization of brain tumours with spin-spin relaxation: pilot case study reveals unique T 2 distribution profiles of glioblastoma, oligodendroglioma and meningioma.

Authors:  Cornelia Laule; Thorarin A Bjarnason; Irene M Vavasour; Anthony L Traboulsee; G R Wayne Moore; David K B Li; Alex L MacKay
Journal:  J Neurol       Date:  2017-09-11       Impact factor: 4.849

9.  Optimal echo spacing for multi-echo imaging measurements of Bi-exponential T2 relaxation.

Authors:  Adrienne N Dula; Daniel F Gochberg; Mark D Does
Journal:  J Magn Reson       Date:  2008-11-12       Impact factor: 2.229

10.  Multi-slice myelin water imaging for practical clinical applications at 3.0 T.

Authors:  Junyu Guo; Qing Ji; Wilburn E Reddick
Journal:  Magn Reson Med       Date:  2012-11-06       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.