Literature DB >> 17415692

Comparison of Swedish interactive threshold algorithm and full threshold algorithm for glaucomatous visual field loss.

Y Aoki1, G Takahashi, K Kitahara.   

Abstract

PURPOSE: To compare the prevalence of visual field loss, the sensitivity distribution, and the size and depth of glaucomatous visual field defects using the standard full threshold (FT) and the Swedish interactive threshold algorithm (SITA) standard (SS) procedures in patients with early or suspected glaucoma.
METHODS: Automated perimetry findings were retrospectively evaluated in 53 patients (105 eyes) with early or suspected glaucoma.
RESULTS: The number of eyes judged to have glaucomatous visual field loss by SS (48 eyes) was significantly larger than what was found with FT (35 eyes), and 70 eyes were classified as pre-perimetric glaucoma. In these 70 eyes, there were many locations where the sensitivity was significantly higher with SS than with FT (intrasubject difference), and SS had less intersubject variability than FT at most locations. The cumulative decibel scores at the region of glaucomatous defects were larger with SS (206.2+/-103.3 dB) than with FT (162.1+/-87.5 dB) (p=0.02), which indicated that the depth of defects measured by SS was shallower than that by FT. The sizes of defects were significantly larger with SS (11.2+/-5.6) than with FT (9.7+/-5.1) (p<0.05).
CONCLUSIONS: Glaucomatous defects were measured as being significantly shallower and larger with SS than with FT. In addition, the prevalence of visual field defect was higher with SS according to some of the criteria for glaucomatous visual field defects. These results might be related to the fact that SS strategy has a lower variability and to the Bayesian statistical properties of the SITA algorithm.

Entities:  

Mesh:

Year:  2007        PMID: 17415692     DOI: 10.1177/112067210701700208

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  4 in total

1.  Swedish Interactive Threshold Algorithm for central visual field defects unrelated to nerve fiber layer.

Authors:  Kazunori Hirasawa; Nobuyuki Shoji
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-08-18       Impact factor: 3.117

2.  Comparison of the new perimetric GATE strategy with conventional full-threshold and SITA standard strategies.

Authors:  Ulrich Schiefer; John P Pascual; Beth Edmunds; Elisabeth Feudner; Esther M Hoffmann; Chris A Johnson; Wolf A Lagrèze; Norbert Pfeiffer; Pamela A Sample; Flemming Staubach; Richard G Weleber; Reinhard Vonthein; Elke Krapp; Jens Paetzold
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-12-05       Impact factor: 4.799

3.  The Effect of Transitioning from SITA Standard to SITA Faster on Visual Field Performance.

Authors:  Alex T Pham; Pradeep Y Ramulu; Michael V Boland; Jithin Yohannan
Journal:  Ophthalmology       Date:  2021-03-30       Impact factor: 14.277

4.  Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients.

Authors:  Kazunori Hirasawa; Nobuyuki Shoji; Masayuki Kasahara; Kazuhiro Matsumura; Kimiya Shimizu
Journal:  Sci Rep       Date:  2016-05-05       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.