PURPOSE: To estimate cerebral blood perfusion in areas of strong magnetic susceptibility changes with high spatial and temporal resolution using a flow-sensitive alternating inversion recovery (FAIR) arterial spin labeling (ASL) method. MATERIALS AND METHODS: We implemented an ASL method that is capable of imaging perfusion in areas of high magnetic susceptibility changes by combining a FAIR spin preparation with a true fast imaging in steady precession (TrueFISP) data acquisition strategy. A TrueFISP readout sequence was applied especially in regions with magnetic field inhomogeneities and compared with corresponding FAIR measurements obtained with a standard echo-planar imaging (EPI) readout. Quantitative perfusion images were obtained at 1.5 Tesla (1.5T) from eight healthy volunteers (24-42 years old) and one patient (23 years old). FAIR-TrueFISP perfusion images were compared with FAIR echo-planar images. T1 maps, which are necessary for quantitative perfusion estimation, were obtained with inversion recovery (IR) TrueFISP and IR EPI. Additionally, high-resolution perfusion measurements were performed on four volunteers at 3T. RESULTS: The two ASL perfusion imaging modalities yielded comparable diagnostic image quality in brain areas with low susceptibility differences at 1.5T. Cerebral perfusion of gray matter (GM) areas was 105.7 +/- 5.2 mL/100 g/minute for FAIR-TrueFISP and 88.8 +/- 14.6 mL/100 g/minute for FAIR-EPI at 1.5T, and 70.4 +/- 7.1 mL/100 g/minute for FAIR-TrueFISP and 63.5 +/- 6.9 mL/100 g/minute for FAIR-EPI at 3.0T. Higher perfusion values at 1.5T were due to more pronounced partial-volume effects from fast moving spins at lower spatial resolution. The FAIR-TrueFISP sequence showed no significant distortions and markedly reduced signal void artifacts in areas of high susceptibility changes (e.g., near brain-bone transitions and close to metallic clips) compared to FAIR-EPI. At 3T, highly resolved FAIR-TrueFISP perfusion images were acquired with an in-plane resolution of up to 1.3 mm. CONCLUSION: FAIR-TrueFISP allows for assessment of cerebral perfusion in areas of critically high susceptibility changes with conventional ASL methods. (c) 2007 Wiley-Liss, Inc.
PURPOSE: To estimate cerebral blood perfusion in areas of strong magnetic susceptibility changes with high spatial and temporal resolution using a flow-sensitive alternating inversion recovery (FAIR) arterial spin labeling (ASL) method. MATERIALS AND METHODS: We implemented an ASL method that is capable of imaging perfusion in areas of high magnetic susceptibility changes by combining a FAIR spin preparation with a true fast imaging in steady precession (TrueFISP) data acquisition strategy. A TrueFISP readout sequence was applied especially in regions with magnetic field inhomogeneities and compared with corresponding FAIR measurements obtained with a standard echo-planar imaging (EPI) readout. Quantitative perfusion images were obtained at 1.5 Tesla (1.5T) from eight healthy volunteers (24-42 years old) and one patient (23 years old). FAIR-TrueFISP perfusion images were compared with FAIR echo-planar images. T1 maps, which are necessary for quantitative perfusion estimation, were obtained with inversion recovery (IR) TrueFISP and IR EPI. Additionally, high-resolution perfusion measurements were performed on four volunteers at 3T. RESULTS: The two ASL perfusion imaging modalities yielded comparable diagnostic image quality in brain areas with low susceptibility differences at 1.5T. Cerebral perfusion of gray matter (GM) areas was 105.7 +/- 5.2 mL/100 g/minute for FAIR-TrueFISP and 88.8 +/- 14.6 mL/100 g/minute for FAIR-EPI at 1.5T, and 70.4 +/- 7.1 mL/100 g/minute for FAIR-TrueFISP and 63.5 +/- 6.9 mL/100 g/minute for FAIR-EPI at 3.0T. Higher perfusion values at 1.5T were due to more pronounced partial-volume effects from fast moving spins at lower spatial resolution. The FAIR-TrueFISP sequence showed no significant distortions and markedly reduced signal void artifacts in areas of high susceptibility changes (e.g., near brain-bone transitions and close to metallic clips) compared to FAIR-EPI. At 3T, highly resolved FAIR-TrueFISP perfusion images were acquired with an in-plane resolution of up to 1.3 mm. CONCLUSION: FAIR-TrueFISP allows for assessment of cerebral perfusion in areas of critically high susceptibility changes with conventional ASL methods. (c) 2007 Wiley-Liss, Inc.
Authors: Petros Martirosian; Andreas Boss; Christina Schraml; Nina F Schwenzer; Hansjörg Graf; Claus D Claussen; Fritz Schick Journal: Eur J Nucl Med Mol Imaging Date: 2010-08 Impact factor: 9.236
Authors: Lirong Yan; Sumei Wang; Yan Zhuo; Ronald L Wolf; Michael F Stiefel; Jing An; Yongquan Ye; Qian Zhang; Elias R Melhem; Danny J J Wang Journal: Radiology Date: 2010-07 Impact factor: 11.105
Authors: Andreas Boss; Petros Martirosian; Jan Fritz; Ina Kötter; Jörg C Henes; Claus D Claussen; Fritz Schick; Marius Horger Journal: MAGMA Date: 2009-01-27 Impact factor: 2.310
Authors: Adolf Pfefferbaum; Torsten Rohlfing; Margaret J Rosenbloom; Weiwei Chu; Ian M Colrain; Edith V Sullivan Journal: Neuroimage Date: 2012-10-12 Impact factor: 6.556