Literature DB >> 17410560

Quadrature coil design for high-resolution carotid artery imaging scores better than a dual phased-array coil design with the same volume coverage.

Mohamed Ouhlous1, Adriaan Moelker, Herman J Flick, Piotr A Wielopolski, Thomas T de Weert, Peter M T Pattynama, Aad van der Lugt.   

Abstract

PURPOSE: To evaluate the ability of a custom-built coil design to provide improved signal-to-noise ratio (SNR) and less signal drop with increasing depth at the carotid artery.
MATERIALS AND METHODS: Phased-array surface coils can provide a high SNR to image the carotid vessel wall. However, given the required field-of-view (FOV) and penetration depth, these coils show either a fast signal drop with increasing depth or a moderate SNR at increased coil size. A quadrature surface coil (a butterfly coil in conjunction with a linear single-loop coil) was compared with a phased-array coil in phantom and human studies.
RESULTS: The phantom studies showed that the quadrature coil has better SNR over the required FOV than a standard phased-array coil (26% at 3 cm depth).
CONCLUSION: The quadrature coil enables better image quality to be achieved. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17410560     DOI: 10.1002/jmri.20894

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  5 in total

Review 1.  Advanced techniques for MRI of atherosclerotic plaque.

Authors:  William S Kerwin; Gador Canton
Journal:  Top Magn Reson Imaging       Date:  2009-08

2.  Improvements in carotid plaque imaging using a new eight-element phased array coil at 3T.

Authors:  Niranjan Balu; Vasily L Yarnykh; Joshua Scholnick; Baocheng Chu; Chun Yuan; Cecil Hayes
Journal:  J Magn Reson Imaging       Date:  2009-11       Impact factor: 4.813

3.  Partially orthogonal resonators for magnetic resonance imaging.

Authors:  Jorge Chacon-Caldera; Matthias Malzacher; Lothar R Schad
Journal:  Sci Rep       Date:  2017-02-10       Impact factor: 4.379

4.  Comparison of four MR carotid surface coils at 3T.

Authors:  Qinwei Zhang; Bram F Coolen; Sandra van den Berg; Gyula Kotek; Debra S Rivera; Dennis W J Klomp; Gustav J Strijkers; Aart J Nederveen
Journal:  PLoS One       Date:  2019-03-04       Impact factor: 3.240

5.  Planar quadrature RF transceiver design using common-mode differential-mode (CMDM) transmission line method for 7T MR imaging.

Authors:  Ye Li; Baiying Yu; Yong Pang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  PLoS One       Date:  2013-11-12       Impact factor: 3.240

  5 in total