Literature DB >> 17401571

Minimally invasive plating for complex humeral shaft fractures.

Rui Jiang1, Cong-Feng Luo, Bing-Fang Zeng, Guo-Hua Mei.   

Abstract

INTRODUCTION: The treatment for humeral shaft fracture is still controversial, especially for complex fractures. The purpose of this study was to evaluate the clinical and radiographic outcomes of treating complex humeral shaft fractures by using locking compression plate with minimally invasive technique.
MATERIALS AND METHODS: A total of 21 patients with 21 acute complex humeral shaft fractures (AO type C) were included in this study. All were treated with locking compression plate in a minimally invasive way. The average age of the patients was 42.9 years and there were 14 males and 7 females. Plain radiographs of humerus were used to assess bony union. Functional recovery of the shoulder joint was assessed using the Constant and HSS scoring systems.
RESULTS: The patients were followed for a mean of 28.7 months (range 19-37). With one operation, nineteen fractures (90.4%) achieved a solid union in an average of 14.3 weeks. At final follow-up, 20 patients (95.2%) had satisfactory alignment, except for one associated with olecranon fracture, all patients had a good to excellent elbow function with a mean HSS score of 91.7 points. Eighteen patients (85.7%) achieved satisfactory shoulder function with a mean Constant score of 83.1 points. One superficial infection (4.8%) and two non-unions (9.6%) were found postoperatively.
CONCLUSIONS: It was concluded that use of a minimally invasive plate osteosynthesis with locking compression plate is a safe alternative way to classic surgical methods in the treatment of complex humeral shaft fractures, which had a high union rate with less risk of complications.

Entities:  

Mesh:

Year:  2007        PMID: 17401571     DOI: 10.1007/s00402-007-0313-z

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  19 in total

1.  Is MIPO in humeral shaft fractures really safe? Postoperative ultrasonographic evaluation.

Authors:  Bruno Livani; William Belangero; Kleber Andrade; Guilherme Zuiani; Raphael Pratali
Journal:  Int Orthop       Date:  2008-08-13       Impact factor: 3.075

2.  The treatment of distal third humeral diaphyseal fractures: Is there still a place for the external fixation?

Authors:  N Tartaglia; G Vicenti; M Carrozzo; A Abate; F Rifino; G Picca; G Solarino; B Moretti
Journal:  Musculoskelet Surg       Date:  2016-11-30

3.  Interventions for humeral shaft fractures: mixed treatment comparisons of clinical trials.

Authors:  Y Zhao; J Wang; W Yao; Q Cai; Y Wang; W Yuan; S Gao
Journal:  Osteoporos Int       Date:  2017-08-05       Impact factor: 4.507

4.  Internal fixation of humeral shaft fractures using minimally invasive plating: comparative study of two implants.

Authors:  Longxiang Shen; Hui Qin; Zhiquan An; Bingfang Zeng; Famin Yang
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-07-05

5.  Less invasive plate osteosynthesis in humeral shaft fractures.

Authors:  Theerachai Apivatthakakul; Chanakarn Phornphutkul; Anupong Laohapoonrungsee; Yuddhasert Sirirungruangsarn
Journal:  Oper Orthop Traumatol       Date:  2009-12       Impact factor: 1.154

6.  [Minimally invasive plating osteosynthesis of proximal humeral shaft fractures with long PHILOS plates].

Authors:  A Brunner; S Thormann; R Babst
Journal:  Oper Orthop Traumatol       Date:  2012-09       Impact factor: 1.154

7.  Minimally invasive plate osteosynthesis for humeral shaft fractures: are results reproducible?

Authors:  Juan M Concha; Alejandro Sandoval; Philipp N Streubel
Journal:  Int Orthop       Date:  2009-10-21       Impact factor: 3.075

Review 8.  [Current status of minimally invasive plate osteosynthesis: specific part II].

Authors:  T Neubauer; M Wagner
Journal:  Unfallchirurg       Date:  2009-11       Impact factor: 1.000

9.  Anterior plating as a surgical alternative in the treatment of humeral shaft non-union.

Authors:  Bruno Livani; William Belangero; Giovanna Medina; Ciro Pimenta; Rodrigo Zogaib; Mauricio Mongon
Journal:  Int Orthop       Date:  2010-10       Impact factor: 3.075

10.  Newly designed minimally invasive plating of a humerus shaft fracture; a different introduction of the plate.

Authors:  Tongjoo Lee; Jaesik Yoon
Journal:  Int Orthop       Date:  2016-01-21       Impact factor: 3.075

View more