Literature DB >> 19844708

Minimally invasive plate osteosynthesis for humeral shaft fractures: are results reproducible?

Juan M Concha1, Alejandro Sandoval, Philipp N Streubel.   

Abstract

Minimally invasive plate osteosynthesis (MIPO) has been advocated as a safe approach to humeral shaft fracture management. We evaluated the reproducibility of this technique in a regional hospital. Thirty-five patients underwent MIPO of humerus shaft fractures. Fifteen patients had an open fracture, six a preoperative radial nerve palsy, and nine a concomitant thoracic, musculoskeletal or vascular injury. At an average 12-month follow-up, 91% of fractures healed after a mean of 12 weeks (range, 8-16). Two infections occurred. Final alignment averaged 4° of varus (range, 5° of valgus to 20° of varus). Active elbow ROM averaged 114° (range, 60-135°) and was less than 100° in nine elbows. Five of six preoperative radial nerve injuries recovered spontaneously. Healing and infection rates in this study are consistent with those reported in the literature. Lower elbow ROM and higher fracture angulation at healing were nevertheless found. MIPO is technically demanding and requires adequate intraoperative imaging and surgical experience in order to obtain adequate fracture alignment. Brachialis muscle scarring and inadequate postoperative rehabilitation may be involved in limited elbow range of motion.

Entities:  

Mesh:

Year:  2009        PMID: 19844708      PMCID: PMC2989077          DOI: 10.1007/s00264-009-0893-z

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  26 in total

1.  Plating of humeral shaft fractures--has the pendulum swung back?

Authors:  D M Niall; J O'Mahony; J P McElwain
Journal:  Injury       Date:  2004-06       Impact factor: 2.586

2.  Plate fixation of the humeral shaft for acute fractures, with and without radial nerve injuries.

Authors:  E J Dabezies; C J Banta; C P Murphy; R D d'Ambrosia
Journal:  J Orthop Trauma       Date:  1992       Impact factor: 2.512

3.  Fractures of the shaft of the humerus.

Authors:  L Klenerman
Journal:  J Bone Joint Surg Br       Date:  1966-02

4.  Randomized prospective study of humeral shaft fracture fixation: intramedullary nails versus plates.

Authors:  J R Chapman; M B Henley; J Agel; P J Benca
Journal:  J Orthop Trauma       Date:  2000 Mar-Apr       Impact factor: 2.512

5.  Fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail. A prospective, randomised trial.

Authors:  R G McCormack; D Brien; R E Buckley; M D McKee; J Powell; E H Schemitsch
Journal:  J Bone Joint Surg Br       Date:  2000-04

Review 6.  [Fractures of the shaft of the humerus: systematic plate fixation. Anatomic and functional results in 156 cases and a review of the literature].

Authors:  H Paris; P Tropiano; B Clouet D'orval; H Chaudet; D G Poitout
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2000-06

7.  Functional bracing for the treatment of fractures of the humeral diaphysis.

Authors:  A Sarmiento; J B Zagorski; G A Zych; L L Latta; C A Capps
Journal:  J Bone Joint Surg Am       Date:  2000-04       Impact factor: 5.284

8.  A biomechanical study of normal functional elbow motion.

Authors:  B F Morrey; L J Askew; E Y Chao
Journal:  J Bone Joint Surg Am       Date:  1981-07       Impact factor: 5.284

9.  Surgical treatment of humeral shaft fractures--the Basel experience.

Authors:  D Heim; F Herkert; P Hess; P Regazzoni
Journal:  J Trauma       Date:  1993-08

10.  Bridging plate osteosynthesis of humeral shaft fractures.

Authors:  Bruno Livani; William Dias Belangero
Journal:  Injury       Date:  2004-06       Impact factor: 2.586

View more
  15 in total

1.  The treatment of distal third humeral diaphyseal fractures: Is there still a place for the external fixation?

Authors:  N Tartaglia; G Vicenti; M Carrozzo; A Abate; F Rifino; G Picca; G Solarino; B Moretti
Journal:  Musculoskelet Surg       Date:  2016-11-30

2.  Minimal invasive ostheosintesis for treatment of diaphiseal transverse humeral shaft fractures.

Authors:  Rodrigo Kallás Zogaib; Steven Morgan; Paulo Santoro Belangero; Hélio Jorge Alvachian Fernandes; William Dias Belangero; Bruno Livani
Journal:  Acta Ortop Bras       Date:  2014       Impact factor: 0.513

3.  Internal fixation of humeral shaft fractures using minimally invasive plating: comparative study of two implants.

Authors:  Longxiang Shen; Hui Qin; Zhiquan An; Bingfang Zeng; Famin Yang
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-07-05

4.  Comparison between osteosynthesis with interlocking nail and minimally invasive plating for proximal- and middle-thirds of humeral shaft fractures.

Authors:  Yao Wang; Huiwen Chen; Lin Wang; Xiao Chen; Xin Zhi; Jin Cui; Liehu Cao
Journal:  Int Orthop       Date:  2020-11-12       Impact factor: 3.075

5.  Treatment of proximal and middle one-third humeral fractures with lateral distal tibial helical plate.

Authors:  Liang Zhang; Lin-Wei Chen; Wen-Jie Zhang; Chun-Ming Zhao; Bo Huang; Qing Yu; Bin Ni
Journal:  Eur J Orthop Surg Traumatol       Date:  2011-12-09

6.  [Minimally invasive plating osteosynthesis of proximal humeral shaft fractures with long PHILOS plates].

Authors:  A Brunner; S Thormann; R Babst
Journal:  Oper Orthop Traumatol       Date:  2012-09       Impact factor: 1.154

7.  Newly designed minimally invasive plating of a humerus shaft fracture; a different introduction of the plate.

Authors:  Tongjoo Lee; Jaesik Yoon
Journal:  Int Orthop       Date:  2016-01-21       Impact factor: 3.075

8.  Long PHILOS plate fixation in a series of humeral fractures.

Authors:  Buchi Arumilli; Norbert Suhm; Jakob Marcel; Daniel Rikli
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-10-02

9.  Humeral shaft fractures.

Authors:  Andre R Spiguel; Robert J Steffner
Journal:  Curr Rev Musculoskelet Med       Date:  2012-09

10.  Radial nerve palsy associated with closed humeral shaft fractures: a systematic review of 1758 patients.

Authors:  Laurent A M Hendrickx; Nick F J Hilgersom; Hassanin Alkaduhimi; Job N Doornberg; Michel P J van den Bekerom
Journal:  Arch Orthop Trauma Surg       Date:  2020-04-13       Impact factor: 3.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.