The intra/inter-examiner reproducibility of the new DIAGNOdent Pen on occlusal sites.

Jan Kühnisch1, Katharina Bücher, Reinhard Hickel.   

Abstract

OBJECTIVE: This in vitro study on occlusal sites aimed to assess the intra/inter-examiner reproducibility of the new DIAGNOdent Pen (KaVo, Biberach, Germany) and to prove the assumption that its handling is easy to learn by dental students.
METHODS: Two hundred and forty-one sites of 90 occlusal non-cavitated molar surfaces were investigated twice by 2 dentists and 2 undergraduate students with the DIAGNOdent Pen according to manufacturer's instructions. Intra/inter-examiner reproducibility was assessed calculating intra-class correlation coefficients (ICCs) and the range of the 95% limits of agreement by Bland and Altman.
RESULTS: Intra-examiner reproducibility revealed excellent ICCs (0.84-0.92); but the range amounted to 41.2-59.1, which indicate a wide measuring range. The inter-examiner reproducibility using all measurements had to be proved as excellent (ICC 0.84); the range was found in the same order of magnitude as mentioned above (53.2). When measurements were categorised according to treatment related cut-offs a good inter-examiner reproducibility was detected in the interval of <30 (ICC 0.70); an excellent ICC were registered for the interval >30 (ICC 0.51). For both intervals the range values (<30: range 32.3 and >30: range 67.7) exceeded a deviation limit of +/-20%. Both students tended to measure slightly more precise compared to the dentists.
CONCLUSIONS: This study revealed a wide measuring range of DIAGNOdent Pen readings. Since there were no differences between dentists and students it can be used as adjunct tool by undergraduates as well. Nevertheless, based on the registered reproducibility the DIAGNOdent Pen should be used additionally to visual inspection and dental radiographs.

Entities:  

Mesh:

Year:  2007        PMID: 17395355     DOI: 10.1016/j.jdent.2007.02.001

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  11 in total

1.  A novel LED-based device for occlusal caries detection.

Authors:  Ali Murat Aktan; Mehmet Ata Cebe; Mehmet Ertuğrul Ciftçi; Emine Sirin Karaarslan
Journal:  Lasers Med Sci       Date:  2011-11-13       Impact factor: 3.161

2.  Impact of measuring multiple or single occlusal lesions on estimates of diagnostic accuracy using fluorescence methods.

Authors:  Anahita Jablonski-Momeni; Simon M Rosen; Helge M Schipper; Richard Stoll; Matthias J Roggendorf; Monika Heinzel-Gutenbrunner; Vitus Stachniss; Klaus Pieper
Journal:  Lasers Med Sci       Date:  2011-01-29       Impact factor: 3.161

3.  Performance of a fluorescence camera for detection of occlusal caries in vitro.

Authors:  Anahita Jablonski-Momeni; Helge Marten Schipper; Simon Martin Rosen; Monika Heinzel-Gutenbrunner; Matthias Johannes Roggendorf; Richard Stoll; Vitus Stachniss; Klaus Pieper
Journal:  Odontology       Date:  2011-01-27       Impact factor: 2.634

4.  Caries detection under composite restorations by laser fluorescence and digital radiography.

Authors:  Suwadee Kositbowornchai; Chotikpanich Sukanya; Tangkittikasem Tidarat; Thongsombat Chanoggarn
Journal:  Clin Oral Investig       Date:  2012-12-16       Impact factor: 3.573

5.  Comparing the reliability of a new fluorescence camera with conventional laser fluorescence devices in detecting caries lesions in occlusal and smooth surfaces of primary teeth.

Authors:  Monique Saveriano De Benedetto; Caroline Carvalho Morais; Tatiane Fernandes Novaes; Jonas de Almeida Rodrigues; Mariana Minatel Braga; Fausto Medeiros Mendes
Journal:  Lasers Med Sci       Date:  2010-02-16       Impact factor: 3.161

6.  In vitro comparison of laser fluorescence performance with visual examination for detection of occlusal caries in permanent and primary molars.

Authors:  Jonas A Rodrigues; Michele B Diniz; Erika B Josgrilberg; Rita C L Cordeiro
Journal:  Lasers Med Sci       Date:  2008-03-29       Impact factor: 3.161

7.  Evaluation of a new fluorescence-based device in the detection of incipient occlusal caries lesions.

Authors:  Eva-Eleni Achilleos; Christos Rahiotis; Afrodite Kakaboura; George Vougiouklakis
Journal:  Lasers Med Sci       Date:  2012-05-11       Impact factor: 3.161

8.  Evaluating performance of dental caries detection methods among third-year dental students.

Authors:  Heini Parviainen; Hannu Vähänikkilä; Marja-Liisa Laitala; Leo Tjäderhane; Vuokko Anttonen
Journal:  BMC Oral Health       Date:  2013-12-06       Impact factor: 2.757

9.  Comparison of Radiography, Laser Fluorescence and Visual Examination for Diagnosing Incipient Occlusal Caries of Permanent First Molars.

Authors:  Zahra Bahrololoomi; Fateme Ezoddini; Niloofar Halvani
Journal:  J Dent (Tehran)       Date:  2015-05

10.  Pen-type laser fluorescence device versus bitewing radiographs for caries detection on approximal surfaces.

Authors:  M Bizhang; N Wollenweber; P Singh-Hüsgen; G Danesh; S Zimmer
Journal:  Head Face Med       Date:  2016-11-04       Impact factor: 2.151

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.