Literature DB >> 17394916

Influence of simulated microwave disinfection on complete denture base adaptation using different flask closure methods.

Rafael Leonardo Xediek Consani1, Marcelo Ferraz Mesquita, Mauro Antonio de Arruda Nobilo, Guilherme Elias Passanha Henriques.   

Abstract

STATEMENT OF PROBLEM: Denture microwave disinfection may result in dimensional changes that may distort the acrylic resin base, causing discomfort to the patient.
PURPOSE: The purpose of this study was to determine the effect of simulated microwave disinfection on maxillary denture base adaptation using 2 different flask closure methods.
MATERIAL AND METHODS: Forty stone cast-wax base sets were prepared for flasking by the traditional flask closure (TFC) and Restriction System flask closure (RSFC) methods (n=20). The RSFC consists of 2 iron plates to hold the flask during definitive flask closure, maintaining the flask in a closed position after release of pressure. Acrylic resin (Classico) was prepared according to the manufacturer's instructions. After polymerization in water at 74 degrees C for 9 hours, the bases were removed following flask cooling and submitted to conventional finishing with abrasive stones and pumice slurry. Ten bases for each TFC or RSFC method (n=10) were submitted to simulated disinfection (SD) in 150 mL distilled water in a microwave oven at 650 W for 3 minutes; control bases for each TFC or RSFC method (n=10) were not disinfected (ND). Three transverse cuts were made through each stone cast-resin base set, corresponding to the distal of canines, mesial of first molars, and posterior palatal region. Measurements were made in the bases using an optical micrometer at 5 points for each cut to determine adaptation: left and right marginal limits of the flanges, left and right ridge crests, and midline. Collected data were submitted to 3-way ANOVA followed by the Tukey HSD test (alpha=.05).
RESULTS: Dimension gap values (mm) for ND denture bases prepared by the RSFC method were significantly lower (0.16 +/- 0.05) when compared to the TFC method (0.21 +/- 0.05) (P<.027). Simulated disinfection statistically improved the base adaptation in bases prepared by the TFC method (0.17 +/- 0.03), compared to the ND bases (0.21 +/- 0.05) (P<.027). Simulated disinfection statistically significantly improved base adaptation (P<.0001) only in the distal of canines (ND=0.13 +/- 0.01; SD=0.11 +/- 0.03) and the posterior palatal region (ND=0.25 +/- 0.04; SD=0.21 +/- 0.01) when bases were prepared by the TFC method.
CONCLUSION: Simulated disinfection by microwave energy improved denture base adaptation when the TFC method was used, but did not statistically alter base adaptation for the RSFC method.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17394916     DOI: 10.1016/j.prosdent.2007.01.006

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

Review 1.  The Effect of Microwave Disinfection on Denture Base Polymers, Liners and Teeth: A Basic Overview.

Authors:  Theodoros Klironomos; Aspasia Katsimpali; Gregory Polyzois
Journal:  Acta Stomatol Croat       Date:  2015-09

2.  In vivo efficacy of alkaline peroxide tablets and mouthwashes on Candida albicans in patients with denture stomatitis.

Authors:  Altay Uludamar; Yasemin Kulak Ozkan; Tanju Kadir; Ismail Ceyhan
Journal:  J Appl Oral Sci       Date:  2010 May-Jun       Impact factor: 2.698

3.  Effect of repeated simulated disinfections by microwave energy on the complete denture base adaptation.

Authors:  Rafael L X Consani; Rose Y Iwasaki; Marcelo F Mesquita; Wilson B Mendes; Simonides Consani
Journal:  Open Dent J       Date:  2008-04-29

4.  Effect of the simulated disinfection by microwave energy on the impact strength of the tooth/acrylic resin adhesion.

Authors:  Rafael L X Consani; Marcelo F Mesquita; Marinaldo H Zampieri; Wilson B Mendes; Simonides Consani
Journal:  Open Dent J       Date:  2008-01-22

5.  Effect of flask closure method and post-pressing time on the displacement of maxillary denture teeth.

Authors:  Wagner A Negreiros; Rafael L X Consani; Marcelo F Mesquita; Mario A C Sinhoreti; Ivan R Faria
Journal:  Open Dent J       Date:  2009-03-06

Review 6.  Biological and Chemo-Physical Features of Denture Resins.

Authors:  Gabriele Cervino; Marco Cicciù; Alan Scott Herford; Antonino Germanà; Luca Fiorillo
Journal:  Materials (Basel)       Date:  2020-07-28       Impact factor: 3.623