Pulmonary emphysema: radiation dose and section thickness at multidetector CT quantification--comparison with macroscopic and microscopic morphometry.

Afarine Madani1, Viviane De Maertelaer, Jacqueline Zanen, Pierre Alain Gevenois.   

Abstract

PURPOSE: To prospectively investigate the effects of radiation dose and section thickness on quantitative multidetector computed tomographic (CT) indexes of pulmonary emphysema.
MATERIALS AND METHODS: The institutional review board approved this protocol. Written informed consent was obtained from all patients. Seventy patients (49 men, 21 women; age range, 38-79 years) referred for surgical resection of a lung tumor underwent multidetector CT with 4 x 1-mm collimation, 120 kVp, and 20 and 120 effective mAs. At each radiation dose, 1.25-, 5.0-, and 10.0-mm-thick sections were reconstructed at 10-mm intervals. From scans of the lobe or whole lung to be resected, relative areas (RAs) of lung with attenuation coefficients lower than nine thresholds and eight percentiles of the distribution of attenuation coefficients were compared with the histopathologic extent of emphysema, which was measured microscopically--by using the corrected mean interwall distance (MIWD) and the corrected mean perimeter (MP)--and macroscopically. Correlations between the data obtained by using attenuation thresholds and percentiles and the parameters macroscopic extent of emphysema, MIWD, and MP were investigated by using Spearman coefficients.
RESULTS: The 1st percentile (r range, -0.394 to -0.675; P < .001) and attenuation coefficients of -980, -970, and -960 HU (r range, 0.478-0.664; P < .001) yielded the strongest correlations with macroscopic extent, MIWD, and MP, regardless of radiation dose or section thickness. The effects of radiation dose and section thickness on RAs of lung with attenuation coefficients lower than -960 HU (P = .007 and P < .001, respectively) and lower than -970 HU (P = .001 and P < .001, respectively) were significant. The effect of section thickness on the 1st percentile was significant (P < .001), whereas the effect of dose was not (P = .910).
CONCLUSION: At CT quantification of pulmonary emphysema, the tube current-time product can be reduced to 20 mAs, but both tube current-time product and section thickness should be kept constant in follow-up examinations.

Entities:  

Mesh:

Year:  2007        PMID: 17392257     DOI: 10.1148/radiol.2431060194

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  68 in total

1.  Extrapolation from ten sections can make CT-based quantification of lung aeration more practicable.

Authors:  A W Reske; A P Reske; H A Gast; M Seiwerts; A Beda; U Gottschaldt; C Josten; D Schreiter; N Heller; H Wrigge; M B Amato
Journal:  Intensive Care Med       Date:  2010-08-06       Impact factor: 17.440

2.  Effect of total lung capacity and gender on CT densitometry indexes.

Authors:  Michel Walsdorff; Alain Van Muylem; Pierre Alain Gevenois
Journal:  Br J Radiol       Date:  2015-11-11       Impact factor: 3.039

Review 3.  Morphological and functional imaging in COPD with CT and MRI: present and future.

Authors:  Julia Ley-Zaporozhan; Sebastian Ley; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2007-09-27       Impact factor: 5.315

4.  Whole-lung densitometry versus visual assessment of emphysema.

Authors:  Edoardo Cavigli; Gianna Camiciottoli; Stefano Diciotti; Ilaria Orlandi; Cheti Spinelli; Eleonora Meoni; Luca Grassi; Carmela Farfalla; Massimo Pistolesi; Fabio Falaschi; Mario Mascalchi
Journal:  Eur Radiol       Date:  2009-02-18       Impact factor: 5.315

5.  Automated lobar quantification of emphysema in patients with severe COPD.

Authors:  Marie-Pierre Revel; Jean-Baptiste Faivre; Martine Remy-Jardin; Valérie Deken; Alain Duhamel; Charles-Hugo Marquette; Nunzia Tacelli; Anne-Marie Bakai; Jacques Remy
Journal:  Eur Radiol       Date:  2008-07-05       Impact factor: 5.315

6.  Quantitative chest tomography in COPD research: chairman's summary.

Authors:  Harvey O Coxson
Journal:  Proc Am Thorac Soc       Date:  2008-12-15

Review 7.  Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstruction.

Authors:  Ji Yung Choo; Jin Mo Goo; Chang Hyun Lee; Chang Min Park; Sang Joon Park; Mi-Suk Shim
Journal:  Eur Radiol       Date:  2013-11-26       Impact factor: 5.315

Review 8.  [Qualitative and quantitative CT analysis of acute pulmonary failure].

Authors:  A W Reske; M Seiwerts
Journal:  Radiologe       Date:  2009-08       Impact factor: 0.635

9.  Inter- and intra-software reproducibility of computed tomography lung density measurements.

Authors:  Miranda Kirby; Charles Hatt; Nancy Obuchowski; Stephen M Humphries; Jered Sieren; David A Lynch; Sean B Fain
Journal:  Med Phys       Date:  2020-03-31       Impact factor: 4.071

Review 10.  CT of pulmonary emphysema--current status, challenges, and future directions.

Authors:  Diana Litmanovich; Phillip M Boiselle; Alexander A Bankier
Journal:  Eur Radiol       Date:  2008-09-30       Impact factor: 5.315