Literature DB >> 17391238

Indoor molds, bacteria, microbial volatile organic compounds and plasticizers in schools--associations with asthma and respiratory symptoms in pupils.

J L Kim1, L Elfman, Y Mi, G Wieslander, G Smedje, D Norbäck.   

Abstract

UNLABELLED: We investigated asthma and atopy in relation to microbial and plasticizer exposure. Pupils in eight primary schools in Uppsala (Sweden) answered a questionnaire, 1014 (68%) participated. Totally, 7.7% reported doctor-diagnosed asthma, 5.9% current asthma, and 12.2% allergy to pollen/pets. Wheeze was reported by 7.8%, 4.5% reported daytime breathlessness, and 2.0% nocturnal breathlessness. Measurements were performed in 23 classrooms (May-June), 74% had <1000 ppm CO(2) indoors. None had visible mold growth or dampness. Mean total microbial volatile organic compound (MVOC) concentration was 423 ng/m(3) indoors and 123 ng/m(3) outdoors. Indoor concentration of TMPD-MIB (2,2,4-trimethyl-1,3-pentanediol monoisobutyrate, Texanol) and TMPD-DIB (2,2,4-trimethyl-1,3-pentanediol diisobutyrate, TXIB), two common plasticizers, were 0.89 and 1.64 microg/m(3), respectively. MVOC and plasticizer concentration were correlated (r = 0.5; P < 0.01). Mold concentration was 360 cfu/m(3) indoors and 980 cfu/m(3) outdoors. At higher indoor concentrations of total MVOC, nocturnal breathlessness (P < 0.01) and doctor-diagnosed asthma (P < 0.05) were more common. Moreover, there were positive associations between nocturnal breathlessness and 3-methylfuran (P < 0.01), 3-methyl-1-butanol (P < 0.05), dimethyldisulfide (P < 0.01), 2-heptanone (P < 0.01), 1-octen-3-ol (P < 0.05), 3-octanone (P < 0.05), TMPD-MIB (P < 0.05), and TMPD-DIB (P < 0.01). TMPD-DIB was positively associated with wheeze (P < 0.05), daytime breathlessness (P < 0.05), doctor-diagnosed asthma (P < 0.05), and current asthma (P < 0.05). In conclusion, exposure to MVOC and plasticizers at school may be a risk factor for asthmatic symptoms in children. PRACTICAL IMPLICATIONS: Despite generally good ventilation and lack of visible signs of mold growth, we found an association between respiratory symptoms and indoor MVOC concentration. In addition, we found associations between asthmatic symptoms and two common plasticizers. The highest levels of MVOC, TMPD-MIB, and TMPD-DIB were found in two new buildings, suggesting that material emissions should be better controlled. As MVOC and plasticizers concentrations were positively correlated, while indoor viable molds and bacteria were negatively correlated, it is unclear if indoor MVOC is an indicator of microbial exposure. Further studies focusing on health effects of chemical emissions from indoor plastic materials, including PVC-floor coatings, are needed.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17391238     DOI: 10.1111/j.1600-0668.2006.00466.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  37 in total

1.  The impact of school building conditions on student absenteeism in Upstate New York.

Authors:  Elinor Simons; Syni-An Hwang; Edward F Fitzgerald; Christine Kielb; Shao Lin
Journal:  Am J Public Health       Date:  2010-07-15       Impact factor: 9.308

2.  Bisphenol A exposure is associated with decreased lung function.

Authors:  Adam J Spanier; Elizabeth K Fiorino; Leonardo Trasande
Journal:  J Pediatr       Date:  2014-03-20       Impact factor: 4.406

3.  Exposure to formaldehyde and asthma outcomes: A systematic review, meta-analysis, and economic assessment.

Authors:  Juleen Lam; Erica Koustas; Patrice Sutton; Amy M Padula; Michael D Cabana; Hanna Vesterinen; Charles Griffiths; Mark Dickie; Natalyn Daniels; Evans Whitaker; Tracey J Woodruff
Journal:  PLoS One       Date:  2021-03-31       Impact factor: 3.240

4.  Indoor air quality in elementary schools of Lisbon in spring.

Authors:  P N Pegas; C A Alves; M G Evtyugina; T Nunes; M Cerqueira; M Franchi; C A Pio; S M Almeida; M C Freitas
Journal:  Environ Geochem Health       Date:  2010-11-02       Impact factor: 4.609

5.  Relation of dampness to sick building syndrome in Japanese public apartment houses.

Authors:  Yasuaki Saijo; Yoshihiko Nakagi; Toshihiro Ito; Yoshihiko Sugioka; Hitoshi Endo; Takahiko Yoshida
Journal:  Environ Health Prev Med       Date:  2008-10-24       Impact factor: 3.674

6.  Influence of relative humidity on VOC concentrations in indoor air.

Authors:  Pawel Markowicz; Lennart Larsson
Journal:  Environ Sci Pollut Res Int       Date:  2014-10-28       Impact factor: 4.223

7.  Fungal-derived semiochemical 1-octen-3-ol disrupts dopamine packaging and causes neurodegeneration.

Authors:  Arati A Inamdar; Muhammad M Hossain; Alison I Bernstein; Gary W Miller; Jason R Richardson; Joan Wennstrom Bennett
Journal:  Proc Natl Acad Sci U S A       Date:  2013-11-11       Impact factor: 11.205

Review 8.  Air pollution and allergic disease.

Authors:  Haejin Kim; Jonathan A Bernstein
Journal:  Curr Allergy Asthma Rep       Date:  2009-03       Impact factor: 4.806

9.  A study on Aspergillus species in houses of asthmatic patients from Sari City, Iran and a brief review of the health effects of exposure to indoor Aspergillus.

Authors:  Mohammad T Hedayati; Sabah Mayahi; David W Denning
Journal:  Environ Monit Assess       Date:  2009-08-21       Impact factor: 2.513

10.  School variation in asthma: compositional or contextual?

Authors:  Tracy K Richmond; S V Subramanian
Journal:  PLoS One       Date:  2009-12-30       Impact factor: 3.240

View more