Literature DB >> 17390224

Fatigue performance of composite analogue femur constructs under high activity loading.

Alexander C M Chong1, Elizabeth A Friis, Gregory P Ballard, Peter J Czuwala, Francis W Cooke.   

Abstract

Synthetic mechanical analogue bone models are valuable tools for consistent analysis of implant performance in both equilibrium and fatigue biomechanical testing. Use of these models has previously been limited by the poor fatigue performance when tested under realistic service loads. An objective was to determine whether a new analogue bone model (Fourth-Generation) using enhanced analogue cortical bone provides significantly improved resistance to high load fracture and fatigue as compared to the current (Third-Generation) bone models in clinically relevant in situ type testing of total hip implants. Six Third-Generation and six Fourth-Generation mechanical analogue proximal femur models were implanted with a cemented mock hip arthroplasty. Each specimen was loaded at 5 Hz in simulated one-legged stance under load control with a maximum compressive load of 2670 N and load ratio of 0.1. Average complete structural failure in Third-Generation femurs occurred at 3.16 million cycles; all specimens exhibited substantial displacement and crazing at well below 3 million cycles. In contrast, all Fourth-Generation femurs sustained 10 million cycles without complete structural failure and showed little change in actuator deflection. The Fourth-Generation femur model performance was sufficient to allow the model to be used in biomechanically relevant load bearing levels with an intramedullary device without model compromise that would affect test results.

Entities:  

Mesh:

Year:  2007        PMID: 17390224     DOI: 10.1007/s10439-007-9284-z

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  14 in total

1.  Maximum load to failure and tensile displacement of an all-suture glenoid anchor compared with a screw-in glenoid anchor.

Authors:  Tim Dwyer; Thomas L Willett; Andrew P Dold; Massimo Petrera; David Wasserstein; Danny B Whelan; John S Theodoropoulos
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-11-08       Impact factor: 4.342

2.  Locking buttons increase fatigue life of locking plates in a segmental bone defect model.

Authors:  Marc Tompkins; David J Paller; Douglas C Moore; Joseph J Crisco; Richard M Terek
Journal:  Clin Orthop Relat Res       Date:  2012-10-27       Impact factor: 4.176

3.  The effect of different torque wrenches on rotational stiffness in compressive femoral nails: a biomechanical study.

Authors:  A A Karaarslan; N Acar
Journal:  Eur J Trauma Emerg Surg       Date:  2017-07-27       Impact factor: 3.693

4.  Biomechanical analysis of a synthetic femoral spiral fracture model: Do end caps improve retrograde flexible intramedullary nail fixation?

Authors:  Martin M Kaiser; Gregor Zachert; Robert Wendlandt; Marion Rapp; Rebecca Eggert; Christine Stratmann; Lucas M Wessel; Arndt P Schulz; Benjamin J Kienast
Journal:  J Orthop Surg Res       Date:  2011-09-18       Impact factor: 2.359

Review 5.  Composite bone models in orthopaedic surgery research and education.

Authors:  John Elfar; Ron Martin Garcia Menorca; Jeffrey Douglas Reed; Spencer Stanbury
Journal:  J Am Acad Orthop Surg       Date:  2014-02       Impact factor: 3.020

Review 6.  The emerging utility of composite bone models in biomechanical studies of the hand and upper extremity.

Authors:  Jeffrey D Reed; Spencer J Stanbury; Ron M Menorca; John C Elfar
Journal:  J Hand Surg Am       Date:  2013-02-04       Impact factor: 2.230

7.  A novel nail providing more biomechanical rotational and axial stability than conventional interlocking nail in femur complex fracture model.

Authors:  A A Karaarslan; N Acar; Y Örgen; H Aycan; F Ertem; E Sesli
Journal:  Eur J Trauma Emerg Surg       Date:  2016-05-03       Impact factor: 3.693

8.  Posterior glenoid wear in total shoulder arthroplasty: eccentric anterior reaming is superior to posterior augment.

Authors:  Tim Wang; Geoffrey D Abrams; Anthony W Behn; Derek Lindsey; Nicholas Giori; Emilie V Cheung
Journal:  Clin Orthop Relat Res       Date:  2015-08-05       Impact factor: 4.176

9.  Type of hip fracture determines load share in intramedullary osteosynthesis.

Authors:  Sebastian Eberle; Claus Gerber; Geert von Oldenburg; Sven Hungerer; Peter Augat
Journal:  Clin Orthop Relat Res       Date:  2009-03-31       Impact factor: 4.176

10.  Feasibility of a braided composite for orthopedic bone cast.

Authors:  Katherine R Evans; Jason P Carey
Journal:  Open Biomed Eng J       Date:  2013-01-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.