Literature DB >> 17386545

Selectivity enhancement of anion-responsive electrodes by pulsed chronopotentiometry.

Kebede L Gemene1, Alexey Shvarev, Eric Bakker.   

Abstract

A large and robust selectivity improvement of ion-selective electrodes is presented for the measurement of abundant ions. An improvement in selectivity by more than two orders of magnitude has been attained for the hydrophilic chloride ions measured in a dilute background of the lipophilic ions perchlorate and salicylate in a pulsed chronopotentiometric measurement mode. This is attributed to a robust kinetic discrimination of the dilute lipophilic ions in this measuring mode, which is not possible to achieve in classical potentiometry. Maximum tolerable concentrations of the interfering ions are found to be on the order of 30 microM before causing substantial changes in potential. As an example of practical relevance, the robust detection of chloride in 72 microM salicylate (reflecting 1:10 diluted blood) with a detection limit of 0.5 mM chloride is demonstrated. Corresponding potentiometric sensors did not give a useful chloride response under these conditions.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17386545      PMCID: PMC1826444          DOI: 10.1016/j.aca.2006.09.042

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  17 in total

1.  Reversible electrochemical monitoring of surface confined reactions at liquid-liquid interfaces by modulation of ion transfer fluxes.

Authors:  Yida Xu; Roland De Marco; Alexey Shvarev; Eric Bakker
Journal:  Chem Commun (Camb)       Date:  2005-05-11       Impact factor: 6.222

2.  Response characteristics of a reversible electrochemical sensor for the polyion protamine.

Authors:  Alexey Shvarev; Eric Bakker
Journal:  Anal Chem       Date:  2005-08-15       Impact factor: 6.986

3.  Distinguishing free and total calcium with a single pulsed galvanostatic ion-selective electrode.

Authors:  Alexey Shvarev; Eric Bakker
Journal:  Talanta       Date:  2004-05-10       Impact factor: 6.057

4.  Carbonate ion-selective electrode with reduced interference from salicylate.

Authors:  Johan Bobacka; Magdalena Maj-Zurawska; Andrzej Lewenstam
Journal:  Biosens Bioelectron       Date:  2003-03       Impact factor: 10.618

5.  Influence of porphyrin structure on anion selectivities of manganese(III) porphyrin based membrane electrodes.

Authors:  N A Chaniotakis; A M Chasser; M E Meyerhoff; J T Groves
Journal:  Anal Chem       Date:  1988-01-15       Impact factor: 6.986

6.  Ion-selective membrane electrode for rapid automated determinations of total carbon dioxide.

Authors:  W J Scott; E Chapoteau; A Kumar
Journal:  Clin Chem       Date:  1986-01       Impact factor: 8.327

7.  Enhanced Serum Carbon Dioxide Measurements with a Silicone Rubber-Based Carbonate Ion-Selective Electrode and a High-pH Dilution Buffer.

Authors:  J H Shin; D S Sakong; H Nam; G S Cha
Journal:  Anal Chem       Date:  1996-01-01       Impact factor: 6.986

8.  Selectivity of polymer membrane-based ion-selective electrodes: self-consistent model describing the potentiometric response in mixed ion solutions of different charge.

Authors:  E Bakker; R K Meruva; E Pretsch; M E Meyerhoff
Journal:  Anal Chem       Date:  1994-10-01       Impact factor: 6.986

9.  Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels: new requirements for selectivities and measuring protocols, and comparison with ICPMS.

Authors:  A Ceresa; E Bakker; B Hattendorf; D Günther; E Pretsch
Journal:  Anal Chem       Date:  2001-01-15       Impact factor: 6.986

10.  Tripodal ionophore with sulfate recognition properties for anion-selective electrodes.

Authors:  M J Berrocal; A Cruz; I H Badr; L G Bachas
Journal:  Anal Chem       Date:  2000-11-01       Impact factor: 6.986

View more
  6 in total

1.  Kinetic modulation of pulsed chronopotentiometric polymeric membrane ion sensors by polyelectrolyte multilayers.

Authors:  Yida Xu; Chao Xu; Alexey Shvarev; Thomas Becker; Roland De Marco; Eric Bakker
Journal:  Anal Chem       Date:  2007-08-21       Impact factor: 6.986

Review 2.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2008-05-21       Impact factor: 6.986

3.  Modern Directions for Potentiometric Sensors.

Authors:  Eric Bakker; Karin Chumbimuni-Torres
Journal:  J Braz Chem Soc       Date:  2008-01-01       Impact factor: 1.838

4.  Selectivity Enhancement for Chloride Ion by In(III)-Porphyrin-Based Polymeric Membrane Electrode Operated in Pulsed Chronopotentiometric Mode.

Authors:  Kebede L Gemene; Mark E Meyerhoff
Journal:  Electroanalysis       Date:  2012-03       Impact factor: 3.223

5.  Reverse current pulse method to restore uniform concentration profiles in ion-selective membranes. 1. Galvanostatic pulse methods with decreased cycle time.

Authors:  Justin M Zook; Erno Lindner
Journal:  Anal Chem       Date:  2009-07-01       Impact factor: 6.986

6.  Direct sensing of total acidity by chronopotentiometric flash titrations at polymer membrane ion-selective electrodes.

Authors:  Kebede L Gemene; Eric Bakker
Journal:  Anal Chem       Date:  2008-03-28       Impact factor: 6.986

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.