Literature DB >> 17379555

Improving excitation and inversion accuracy by optimized RF pulse using genetic algorithm.

Yong Pang1, Gary X Shen.   

Abstract

In this study, a Genetic Algorithm (GA) is introduced to optimize the multidimensional spatial selective RF pulse to reduce the passband and stopband errors of excitation profile while limiting the transition width. This method is also used to diminish the nonlinearity effect of the Bloch equation for large tip angle excitation pulse design. The RF pulse is first designed by the k-space method and then coded into float strings to form an initial population. GA operators are then applied to this population to perform evolution, which is an optimization process. In this process, an evaluation function defined as the sum of the reciprocal of passband and stopband errors is used to assess the fitness value of each individual, so as to find the best individual in current generation. It is possible to optimize the RF pulse after a number of iterations. Simulation results of the Bloch equation show that in a 90 degrees excitation pulse design, compared with the k-space method, a GA-optimized RF pulse can reduce the passband and stopband error by 12% and 3%, respectively, while maintaining the transition width within 2 cm (about 12% of the whole 32 cm FOV). In a 180 degrees inversion pulse design, the passband error can be reduced by 43%, while the transition is also kept at 2 cm in a whole 32 cm FOV.

Entities:  

Mesh:

Year:  2007        PMID: 17379555     DOI: 10.1016/j.jmr.2007.01.016

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  5 in total

1.  Genetic algorithm optimized triply compensated pulses in NMR spectroscopy.

Authors:  V S Manu; Gianluigi Veglia
Journal:  J Magn Reson       Date:  2015-09-28       Impact factor: 2.229

2.  Optimization of identity operation in NMR spectroscopy via genetic algorithm: Application to the TEDOR experiment.

Authors:  V S Manu; Gianluigi Veglia
Journal:  J Magn Reson       Date:  2016-09-27       Impact factor: 2.229

3.  Design and optimization of pulsed Chemical Exchange Saturation Transfer MRI using a multiobjective genetic algorithm.

Authors:  Eriko S Yoshimaru; Edward A Randtke; Mark D Pagel; Julio Cárdenas-Rodríguez
Journal:  J Magn Reson       Date:  2015-12-19       Impact factor: 2.229

4.  Parallel Excitation in Ultrahigh Field Human MR Imaging and Multi-Channel Transmit System.

Authors:  Xiaoliang Zhang; Yong Pang
Journal:  OMICS J Radiol       Date:  2012-05

5.  SFOL Pulse: A High Accuracy DME Pulse for Alternative Aircraft Position and Navigation.

Authors:  Euiho Kim; Jiwon Seo
Journal:  Sensors (Basel)       Date:  2017-09-22       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.