Abstract

Efficient high resolution techniques are required for screening efforts and research targeting ion channels. The conventional patch clamp technique, a high resolution but low efficiency technique, has been established for 25 years. Recent advances have opened up new possibilities for automated patch clamping. This new technology meets the need of drug developers for higher throughput and facilitates new experimental approaches in ion channel research. Specifically, Nanion's electrophysiology workstations, the Port-a-Patch and the Patchliner, have been successfully introduced as high-quality automated patch clamp platforms for industry as well as academic users. Both platforms give high quality patch clamp recordings, capable of true giga-seals and stable recordings, accessible to the user without the need for years of practical training. They also offer sophisticated experimental possibilities, such as accurate and fast ligand application, temperature control and internal solution exchange. This article describes the chip-based patch clamp technology and its usefulness in ion channel drug screening and academic research.

Mesh:

Substances:

Year:  2007        PMID: 17373884     DOI: 10.1517/14728222.11.4.557

Source DB:  PubMed          Journal:  Expert Opin Ther Targets        ISSN: 1472-8222            Impact factor:   6.902


  12 in total

Review 1.  Diverse Applications of Nanomedicine.

Authors:  Beatriz Pelaz; Christoph Alexiou; Ramon A Alvarez-Puebla; Frauke Alves; Anne M Andrews; Sumaira Ashraf; Lajos P Balogh; Laura Ballerini; Alessandra Bestetti; Cornelia Brendel; Susanna Bosi; Monica Carril; Warren C W Chan; Chunying Chen; Xiaodong Chen; Xiaoyuan Chen; Zhen Cheng; Daxiang Cui; Jianzhong Du; Christian Dullin; Alberto Escudero; Neus Feliu; Mingyuan Gao; Michael George; Yury Gogotsi; Arnold Grünweller; Zhongwei Gu; Naomi J Halas; Norbert Hampp; Roland K Hartmann; Mark C Hersam; Patrick Hunziker; Ji Jian; Xingyu Jiang; Philipp Jungebluth; Pranav Kadhiresan; Kazunori Kataoka; Ali Khademhosseini; Jindřich Kopeček; Nicholas A Kotov; Harald F Krug; Dong Soo Lee; Claus-Michael Lehr; Kam W Leong; Xing-Jie Liang; Mei Ling Lim; Luis M Liz-Marzán; Xiaowei Ma; Paolo Macchiarini; Huan Meng; Helmuth Möhwald; Paul Mulvaney; Andre E Nel; Shuming Nie; Peter Nordlander; Teruo Okano; Jose Oliveira; Tai Hyun Park; Reginald M Penner; Maurizio Prato; Victor Puntes; Vincent M Rotello; Amila Samarakoon; Raymond E Schaak; Youqing Shen; Sebastian Sjöqvist; Andre G Skirtach; Mahmoud G Soliman; Molly M Stevens; Hsing-Wen Sung; Ben Zhong Tang; Rainer Tietze; Buddhisha N Udugama; J Scott VanEpps; Tanja Weil; Paul S Weiss; Itamar Willner; Yuzhou Wu; Lily Yang; Zhao Yue; Qian Zhang; Qiang Zhang; Xian-En Zhang; Yuliang Zhao; Xin Zhou; Wolfgang J Parak
Journal:  ACS Nano       Date:  2017-03-14       Impact factor: 15.881

2.  The M34A mutant of Connexin26 reveals active conductance states in pore-suspending membranes.

Authors:  Oliver Gassmann; Mohamed Kreir; Cinzia Ambrosi; Jennifer Pranskevich; Atsunori Oshima; Christian Röling; Gina Sosinsky; Niels Fertig; Claudia Steinem
Journal:  J Struct Biol       Date:  2009-02-21       Impact factor: 2.867

3.  A semi-synthetic ion channel platform for detection of phosphatase and protease activity.

Authors:  Michael X Macrae; Steven Blake; Xiayun Jiang; Ricardo Capone; Daniel J Estes; Michael Mayer; Jerry Yang
Journal:  ACS Nano       Date:  2009-11-24       Impact factor: 15.881

4.  Robotic multiwell planar patch-clamp for native and primary mammalian cells.

Authors:  Carol J Milligan; Jing Li; Piruthivi Sukumar; Yasser Majeed; Mark L Dallas; Anne English; Paul Emery; Karen E Porter; Andrew M Smith; Ian McFadzean; Dayne Beccano-Kelly; Yahya Bahnasi; Alex Cheong; Jacqueline Naylor; Fanning Zeng; Xing Liu; Nikita Gamper; Lin-Hua Jiang; Hugh A Pearson; Chris Peers; Brian Robertson; David J Beech
Journal:  Nat Protoc       Date:  2009       Impact factor: 13.491

5.  Function and regulation of TRPM7, as well as intracellular magnesium content, are altered in cells expressing ΔF508-CFTR and G551D-CFTR.

Authors:  F Huguet; M L Calvez; N Benz; S Le Hir; O Mignen; P Buscaglia; F D Horgen; C Férec; M Kerbiriou; P Trouvé
Journal:  Cell Mol Life Sci       Date:  2016-02-13       Impact factor: 9.207

6.  Automated electrophysiology makes the pace for cardiac ion channel safety screening.

Authors:  Clemens Möller; Harry Witchel
Journal:  Front Pharmacol       Date:  2011-11-23       Impact factor: 5.810

7.  State-of-the-Art Automated Patch Clamp Devices: Heat Activation, Action Potentials, and High Throughput in Ion Channel Screening.

Authors:  Sonja Stoelzle; Alison Obergrussberger; Andrea Brüggemann; Claudia Haarmann; Michael George; Ralf Kettenhofen; Niels Fertig
Journal:  Front Pharmacol       Date:  2011-11-24       Impact factor: 5.810

8.  Development of a Rapid Throughput Assay for Identification of hNav1.7 Antagonist Using Unique Efficacious Sodium Channel Agonist, Antillatoxin.

Authors:  Fang Zhao; Xichun Li; Liang Jin; Fan Zhang; Masayuki Inoue; Boyang Yu; Zhengyu Cao
Journal:  Mar Drugs       Date:  2016-02-16       Impact factor: 5.118

9.  Discovery of Novel HCN4 Blockers with Unique Blocking Kinetics and Binding Properties.

Authors:  Kosuke Nakashima; Kenji Nakao; Hideki Matsui
Journal:  SLAS Discov       Date:  2021-05-27       Impact factor: 3.341

10.  Improvement of chloride transport defect by gonadotropin-releasing hormone (GnRH) in cystic fibrosis epithelial cells.

Authors:  Nathalie Benz; Sophie Le Hir; Caroline Norez; Mathieu Kerbiriou; Marie-Laure Calvez; Frédéric Becq; Pascal Trouvé; Claude Férec
Journal:  PLoS One       Date:  2014-02-19       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.