Acetabular cortical and cancellous bone density and radiolucent lines after cemented total hip arthroplasty: a prospective study using computed tomography and plain radiography.

Lutz Arne Mueller1, Tobias Eckhard Nowak, Lars Peter Mueller, Rainer Schmidt, Cornelia Ehrmann, Rocco Paolo Pitto, David Pfander, Raimund Forst, Stefan Eichinger.   

Abstract

INTRODUCTION: The aim of this prospective study was to evaluate load-transfer mechanisms and stress patterns of periacetabular cortical and cancellous bone after cemented total hip arthroplasty (THA) in vivo using computed tomography (CT) assisted osteodensitometry. In addition we analyzed the efficacy of CT in detecting radiolucent lines around the acetabular component compared to plain radiography.
MATERIALS AND METHODS: Twenty-two cemented acetabular cups were investigated using conventional sequential axial CT scans (Ø 8 days and 26 months post-OP) and plain radiography (Ø 5 days and 40 months post-OP). CT assisted osteodensitometry was used to determine cancellous and cortical bone bone density (BD). Radiolucent lines were evaluated using both CT and plain radiography.
RESULTS: Significant BD loss at the time of follow-up was only detectable ventral to the cup (cortical bone: -16%, P = 0.001; cancellous bone: -31%, P = 0.001). The BD changes dorsal and cranial to the cup were not significant. Postoperatively no radiolucent lines were observed in the cement-bone interface by CT, while on plain radiography acetabular lucent lines were seen in 12 out of 22 cases.
CONCLUSION: CT-osteodensitometry has the technical ability to discriminate between cortical and cancellous bone structures with respect to strain-adapted remodeling: sufficient cancellous and cortical bone stock remained dorsal and cranial to the cup indicative of a balanced load transfer to these regions. CT-osteodensitometry has the potential to become an effective instrument for quality control in THA and the method of choice for in vivo determination of periprosthetic BD. In contrast, plain radiography is more suitable for the early detection of radiolucent lines compared to axial CT scans.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17372748     DOI: 10.1007/s00402-007-0304-0

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  3 in total

1.  Intra- and inter-observer agreement and reliability of bone mineral density measurements around acetabular cup: a porcine ex-vivo study using single- and dual-energy computed tomography.

Authors:  Bo Mussmann; Søren Overgaard; Trine Torfing; Morten Bøgehøj; Oke Gerke; Poul Erik Andersen
Journal:  Acta Radiol Open       Date:  2017-07-14

2.  Cancellous and cortical bone mineral density around an elastic press-fit socket in total hip arthroplasty.

Authors:  Dean F M Pakvis; Petra J C Heesterbeek; Marianne Severens; Maarten Spruit
Journal:  Acta Orthop       Date:  2016-09-23       Impact factor: 3.717

3.  Bone density measurements adjacent to acetabular cups in total hip arthroplasty using dual-energy CT: an in vivo reliability and agreement study.

Authors:  Bo Mussmann; Poul Erik Andersen; Trine Torfing; Søren Overgaard
Journal:  Acta Radiol Open       Date:  2018-08-30