Literature DB >> 17367116

Open air calibration with temperature compensation of a luminescence quenching-based oxygen sensor for portable instrumentation.

Alberto J Palma1, Javier López-González, Luis J Asensio, María Dolores Fernández-Ramos, Luis Fermín Capitán-Vallvey.   

Abstract

This report addresses the task of calibrating an optical sensor for oxygen determination. Detailed analyses of the functional dependences from our measurement system results have been carried out with the additional aim of temperature compensation. As a result, an empirical calibration function has been successfully derived for the luminescent quenching-based oxygen sensor included in a self-designed portable instrument. This function also compensates for the temperature influence on the quenching luminescence process in the range from 0 to 45 degrees C. Moreover, the calibration procedure is extremely simple because only a single standard is needed. In fact, the oxygen measurement system can be calibrated with exposure to an open air atmosphere, and therefore, neither laboratory standards nor trained personnel are required. The method has been applied to a set of 11 units of the mentioned sensor (up to 24% oxygen concentration) giving an overall deviation between our calibrated system results and the laboratory standards of 0.3% oxygen concentration (calculated with 95% confidence level). The proposed calibration function has shown itself to be applicable for different sensing film thicknesses and luminophore concentrations using the same fittings parameter. Additionally, this function has been successfully applied to other oxygen dyes. Good agreement has also been found when the performance of the instrument was compared to a commercially available portable instrument based on an electrochemical sensor. We believe that this work could be an interesting finding for spreading the use of optical sensors for atmospheric oxygen determination in commercial measurement equipment for different purposes in confined working atmospheres, such as mines, undergrounds, warehouses, vehicles, and ships.

Entities:  

Year:  2007        PMID: 17367116     DOI: 10.1021/ac062246d

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Optical Oxygen Sensor Patch Printed with Polystyrene Microparticles-based Ink on Flexible Substrate.

Authors:  Mousumi Bose; Jason Hagerty; Jason Boes; Chang-Soo Kim; William Stoecker; Paul Nam
Journal:  IEEE Sens J       Date:  2021-08-18       Impact factor: 4.325

Review 2.  State-of-the-art of (bio)chemical sensor developments in analytical Spanish groups.

Authors:  María Reyes Plata; Ana María Contento; Angel Ríos
Journal:  Sensors (Basel)       Date:  2010-03-24       Impact factor: 3.576

3.  Smart facemask for wireless CO2 monitoring.

Authors:  P Escobedo; M D Fernández-Ramos; N López-Ruiz; O Moyano-Rodríguez; A Martínez-Olmos; I M Pérez de Vargas-Sansalvador; M A Carvajal; L F Capitán-Vallvey; A J Palma
Journal:  Nat Commun       Date:  2022-01-10       Impact factor: 14.919

Review 4.  Review of Dissolved Oxygen Detection Technology: From Laboratory Analysis to Online Intelligent Detection.

Authors:  Yaoguang Wei; Yisha Jiao; Dong An; Daoliang Li; Wenshu Li; Qiong Wei
Journal:  Sensors (Basel)       Date:  2019-09-16       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.