Effect of disinfection treatments on the hardness of soft denture liner materials.

Sabrina Pavan1, João Neudenir Arioli Filho, Paulo Henrique Dos Santos, Sérgio Sualdini Nogueira, André Ulisses Dantas Batista.   

Abstract

PURPOSE: To evaluate the effects of disinfection treatments with chemical solutions (2% glutaraldehyde, 5% sodium hypochlorite, and 5% chlorhexidine) and microwave energy on the hardness of four long-term soft denture liners.
MATERIALS AND METHODS: Forty rectangular specimens of four soft lining materials (Molloplast-B, Ufi Gel P, Eversoft, and Mucopren soft) were made for each material. Ten samples of each material were immersed in different disinfectant solutions for 10 minutes or placed in a microwave oven for 3 minutes at 500 W. The hardness values were obtained with a Shore A durometer, before the first disinfection cycle (control), and also after two cycles of disinfection. Data were submitted to analysis of variance and Tukey's test (p < 0.01).
RESULTS: The highest value of hardness was obtained for Molloplast-B, independent of the disinfection technique. Mucopren soft demonstrated intermediate values and Ufi Gel P and Eversoft the lowest values of Shore A hardness. For Molloplast-B, the disinfection using glutaraldehyde demonstrated the highest value of hardness. The number of disinfections had no effect on the hardness values for all the materials studied and disinfection techniques.
CONCLUSIONS: The application of two disinfection cycles did not change the Shore A hardness values for all the materials. The glutaraldehyde solution demonstrated the highest values of Shore A hardness for the Molloplast-B, Mucopren soft, and Ufi Gel P materials, while Eversoft did not present any differences in hardness when submitted to different disinfection treatments.

Entities:  

Mesh:

Year:  2007        PMID: 17362419     DOI: 10.1111/j.1532-849X.2007.00162.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  5 in total

Review 1.  Antifungal activity and Shore A hardness of a tissue conditioner incorporated with terpinen-4-ol and cinnamaldehyde.

Authors:  Laura de Fátima Souto Maior; Panmella Pereira Maciel; Victor Yuri Nicolau Ferreira; Cíntia de Lima Gouveia Dantas; Jeferson Muniz de Lima; Lúcio Roberto Cançado Castellano; André Ulisses Dantas Batista; Paulo Rogério Ferreti Bonan
Journal:  Clin Oral Investig       Date:  2019-05-20       Impact factor: 3.573

Review 2.  The Effect of Microwave Disinfection on Denture Base Polymers, Liners and Teeth: A Basic Overview.

Authors:  Theodoros Klironomos; Aspasia Katsimpali; Gregory Polyzois
Journal:  Acta Stomatol Croat       Date:  2015-09

Review 3.  Long-Term Soft Denture Lining Materials.

Authors:  Grzegorz Chladek; Jarosław Żmudzki; Jacek Kasperski
Journal:  Materials (Basel)       Date:  2014-08-12       Impact factor: 3.623

4.  The Influence of Decontamination Procedures on the Surface of Two Polymeric Liners Used in Prosthodontics.

Authors:  Katarzyna Mańka-Malara; Maciej Trzaskowski; Dominika Gawlak
Journal:  Polymers (Basel)       Date:  2021-12-11       Impact factor: 4.329

5.  The effect of thermocycling on tensile bond strength of two soft liners.

Authors:  Farideh Geramipanah; Masoumeh Ghandari; Somayeh Zeighami
Journal:  J Dent (Tehran)       Date:  2013-09-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.