Literature DB >> 17361389

Determination of functional residual capacity by oxygen washin-washout: a validation study.

Stefan Maisch1, Stephan H Boehm2, Dieter Weismann3, Hajo Reissmann2, Marcus Beckmann2, Bernd Fuellekrug2, Andreas Meyer4, Jochen Schulte Am Esch2.   

Abstract

OBJECTIVE: To validate a new system for functional residual capacity (FRC) measurements using oxygen washin/washout in spontaneously breathing humans. The system (LUFU, Drägerwerk AG, Lübeck, Germany) consists of an unmodified EVITA 4 ventilator, a side-stream paramagnetic oxygen sensor and a dedicated software.
DESIGN: Laboratory study and measurements in spontaneously breathing volunteers.
SETTING: Pulmonary function laboratory of a university hospital. PARTICIPANTS: 20 healthy and 15 lung diseased volunteers.
INTERVENTIONS: FRC was measured by LUFU (LUFU-FRC) and by helium dilution (He-FRC); intra-thoracic gas volume (ITGV) was determined by body plethysmography. Each measurement cycle consisted of four independent LUFU-FRC determinations (step change of FiO(2) from 0.21 to 0.5 and back and from 0.21 to 1.0 and back), two helium-dilution runs and two body box measurements. Repeatability and agreement between methods were determined by comparing different measurements of one technique and by comparing different techniques among each other. MEASUREMENTS AND
RESULTS: Repeatability of LUFU-FRC was estimated by comparing washin to washout and the different FiO(2)steps. The difference of the means was 3.7% at the most. Agreement between methods resulted in the following differences (mean+/-standard deviation of differences) for healthy and lung-diseased volunteers, respectively: LUFU-FRC vs. He-FRC -0.40+/-0.50 L (0.02+/-0.95 L), LUFU-FRC vs. ITGV -0.43+/-0.54 L (-0.18+/-0.61 L) and He-FRC vs. ITGV -0.03+/-0.43 L (-0.20+/-0.98 L).
CONCLUSIONS: LUFU is a non-invasive method for the determination of FRC that requires only minor additional equipment and no modification to the ventilator. It can be used in difficult conditions such as breathing patterns with variations from breath to breath. The results of this study show that LUFU is sufficiently reliable and repeatable to warrant its clinical application.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17361389     DOI: 10.1007/s00134-007-0578-2

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  17 in total

1.  Variability of routine pulmonary function tests.

Authors:  J Hruby; J Butler
Journal:  Thorax       Date:  1975-10       Impact factor: 9.139

2.  Real-time moment analysis of pulmonary nitrogen washout.

Authors:  J Saniie; G M Saidel; E H Chester
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1979-06

3.  [Measurement of the functional residual capacity: comparison of 3 methods: spirographic, radiographic and plethysmographic method in 100 normal adults].

Authors:  J Germouty; G Charruyer-Latrille; M Boyer; A Charles; A Jaubert; J Chatelut; D Chantegreil; C Germouty
Journal:  Poumon Coeur       Date:  1970

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Monitoring of functional residual capacity by an oxygen washin/washout; technical description and evaluation.

Authors:  Dieter Weismann; Hajo Reissmann; Stefan Maisch; Bernd Füllekrug; Jochen Schulte
Journal:  J Clin Monit Comput       Date:  2006-07-11       Impact factor: 2.502

6.  The recording of FRC--is it of importance and can it be made simple?

Authors:  G Hedenstierna
Journal:  Intensive Care Med       Date:  1993       Impact factor: 17.440

7.  Automated evaluation of functional residual capacity by oxygen washout.

Authors:  Wolfgang Eichler; Jan Schumacher; Angela Roth-Isigkeit; Jörg Braun; Hermann Kuppe; Karl-Friedrich Klotz
Journal:  J Clin Monit Comput       Date:  2002 Apr-May       Impact factor: 2.502

Review 8.  Comparison of methods of measuring static lung volumes.

Authors:  A H Kendrick
Journal:  Monaldi Arch Chest Dis       Date:  1996-10

9.  Monitoring functional residual capacity (FRC) by quantifying oxygen/carbon dioxide fluxes during a short apnea.

Authors:  Ola Stenqvist; C Olegård; S Søndergaard; H Odenstedt; S Kárason; S Lundin
Journal:  Acta Anaesthesiol Scand       Date:  2002-07       Impact factor: 2.105

10.  [Comparison of body plethysmographic measurement of intrathoracic gas volume and oscillatory measurement of functional residual air capacity in healthy volunteers, miners with and without airway obstruction and in patients not exposed to dust but with obstructive airway disease].

Authors:  H Hildebrand; M S Islam; W T Ulmer
Journal:  Prax Klin Pneumol       Date:  1984-06
View more
  8 in total

Review 1.  The physical basis of ventilator-induced lung injury.

Authors:  Maria Plataki; Rolf D Hubmayr
Journal:  Expert Rev Respir Med       Date:  2010-06       Impact factor: 3.772

2.  Evaluation of a CO2 partial rebreathing functional residual capacity measurement method for use during mechanical ventilation.

Authors:  Lara Brewer; Joseph Orr; Earl Fulcher; Boaz Markewitz
Journal:  J Clin Monit Comput       Date:  2011-11-06       Impact factor: 2.502

3.  Measurement of end-expiratory lung volume by oxygen washin-washout in controlled and assisted mechanically ventilated patients.

Authors:  N Patroniti; M Saini; A Zanella; D Weismann; S Isgrò; G Bellani; G Foti; A Pesenti
Journal:  Intensive Care Med       Date:  2008-07-23       Impact factor: 17.440

4.  Accuracy and precision of end-expiratory lung-volume measurements by automated nitrogen washout/washin technique in patients with acute respiratory distress syndrome.

Authors:  Jean Dellamonica; Nicolas Lerolle; Cyril Sargentini; Gaetan Beduneau; Fabiano Di Marco; Alain Mercat; Jean-Christophe M Richard; Jean-Luc Diehl; Jordi Mancebo; Jean-Jacques Rouby; Qin Lu; Gilles Bernardin; Laurent Brochard
Journal:  Crit Care       Date:  2011-12-07       Impact factor: 9.097

5.  Bedside monitoring of lung volume available for gas exchange.

Authors:  Minh C Tran; Douglas C Crockett; John N Cronin; João Batista Borges; Göran Hedenstierna; Anders Larsson; Andrew D Farmery; Federico Formenti
Journal:  Intensive Care Med Exp       Date:  2021-01-11

6.  Respiratory bi-directional pressure and flow data collection device with thoracic and abdominal circumferential monitoring.

Authors:  Ella F S Guy; J Geoffrey Chase; Lui R Holder-Pearson
Journal:  HardwareX       Date:  2022-08-27

7.  Nitrogen washout/washin, helium dilution and computed tomography in the assessment of end expiratory lung volume.

Authors:  Davide Chiumello; Massimo Cressoni; Monica Chierichetti; Federica Tallarini; Marco Botticelli; Virna Berto; Cristina Mietto; Luciano Gattinoni
Journal:  Crit Care       Date:  2008-12-01       Impact factor: 9.097

8.  Assessment of ventilation inhomogeneity during mechanical ventilation using a rapid-response oxygen sensor-based oxygen washout method.

Authors:  Ido G Bikker; Wim Holland; Patricia Specht; Can Ince; Diederik Gommers
Journal:  Intensive Care Med Exp       Date:  2014-04-16
  8 in total