Literature DB >> 17357730

Phase unwrapping via graph cuts.

José M Bioucas-Dias1, Gonçalo Valadão.   

Abstract

Phase unwrapping is the inference of absolute phase from modulo-2pi phase. This paper introduces a new energy minimization framework for phase unwrapping. The considered objective functions are first-order Markov random fields. We provide an exact energy minimization algorithm, whenever the corresponding clique potentials are convex, namely for the phase unwrapping classical Lp norm, with p > or = 1. Its complexity is KT (n, 3n), where K is the length of the absolute phase domain measured in 2pi units and T (n, m) is the complexity of a max-flow computation in a graph with n nodes and m edges. For nonconvex clique potentials, often used owing to their discontinuity preserving ability, we face an NP-hard problem for which we devise an approximate solution. Both algorithms solve integer optimization problems by computing a sequence of binary optimizations, each one solved by graph cut techniques. Accordingly, we name the two algorithms PUMA, for phase unwrappping max-flow/min-cut. A set of experimental results illustrates the effectiveness of the proposed approach and its competitiveness in comparison with state-of-the-art phase unwrapping algorithms.

Mesh:

Year:  2007        PMID: 17357730     DOI: 10.1109/tip.2006.888351

Source DB:  PubMed          Journal:  IEEE Trans Image Process        ISSN: 1057-7149            Impact factor:   10.856


  27 in total

1.  Graph-cut energy minimization for object extraction in MRCP medical images.

Authors:  Rajasvaran Logeswaran; Dongho Kim; Jungwhan Kim; Keechul Jung; Bundo Song
Journal:  J Med Syst       Date:  2010-04-06       Impact factor: 4.460

2.  Magnetic resonance cholangiopancreatography image enhancement for automatic disease detection.

Authors:  Rajasvaran Logeswaran
Journal:  World J Radiol       Date:  2010-07-28

3.  MR elastography and diffusion-weighted imaging of ex vivo prostate cancer: quantitative comparison to histopathology.

Authors:  Ramin S Sahebjavaher; Guy Nir; Louis O Gagnon; Joseph Ischia; Edward C Jones; Silvia D Chang; Andrew Yung; Mohammad Honarvar; Ladan Fazli; S Larry Goldenberg; Robert Rohling; Ralph Sinkus; Piotr Kozlowski; Septimiu E Salcudean
Journal:  NMR Biomed       Date:  2014-11-10       Impact factor: 4.044

4.  Effect of Normal Breathing on the Movement of CSF in the Spinal Subarachnoid Space.

Authors:  C Gutiérrez-Montes; W Coenen; M Vidorreta; S Sincomb; C Martínez-Bazán; A L Sánchez; V Haughton
Journal:  AJNR Am J Neuroradiol       Date:  2022-08-18       Impact factor: 4.966

5.  High-resolution, large dynamic range field map estimation.

Authors:  Joseph Dagher; Timothy Reese; Ali Bilgin
Journal:  Magn Reson Med       Date:  2013-02-11       Impact factor: 4.668

6.  Robust water/fat separation in the presence of large field inhomogeneities using a graph cut algorithm.

Authors:  Diego Hernando; P Kellman; J P Haldar; Z-P Liang
Journal:  Magn Reson Med       Date:  2010-01       Impact factor: 4.668

7.  Between-centre variability in transfer function analysis, a widely used method for linear quantification of the dynamic pressure-flow relation: the CARNet study.

Authors:  Aisha S S Meel-van den Abeelen; David M Simpson; Lotte J Y Wang; Cornelis H Slump; Rong Zhang; Takashi Tarumi; Caroline A Rickards; Stephen Payne; Georgios D Mitsis; Kyriaki Kostoglou; Vasilis Marmarelis; Dae Shin; Yu-Chieh Tzeng; Philip N Ainslie; Erik Gommer; Martin Müller; Alexander C Dorado; Peter Smielewski; Bernardo Yelicich; Corina Puppo; Xiuyun Liu; Marek Czosnyka; Cheng-Yen Wang; Vera Novak; Ronney B Panerai; Jurgen A H R Claassen
Journal:  Med Eng Phys       Date:  2014-04-13       Impact factor: 2.242

8.  A graph theoretic approach for computing 3D+time biventricular cardiac strain from tagged MRI data.

Authors:  Ming Li; Himanshu Gupta; Steven G Lloyd; Louis J Dell'Italia; Thomas S Denney
Journal:  Med Image Anal       Date:  2016-06-11       Impact factor: 8.545

9.  Efficient phase unwrapping architecture for digital holographic microscopy.

Authors:  Wen-Jyi Hwang; Shih-Chang Cheng; Chau-Jern Cheng
Journal:  Sensors (Basel)       Date:  2011-09-27       Impact factor: 3.576

10.  Dual echo Dixon imaging with a constrained phase signal model and graph cuts reconstruction.

Authors:  Eric G Stinson; Joshua D Trzasko; Joel G Fletcher; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2017-02-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.