Literature DB >> 17357177

Simultaneous determination of phenylglyoxylic acid, mandelic acid, styrene glycol and hippuric acid in primary culture of rat hepatocytes incubate by high-performance liquid chromatography.

Jin-Zhao Wang1, Xin-Yan Lu, Na-Ping Zhao, Yi-Yu Cheng, Su Zeng.   

Abstract

A simple HPLC method for the simultaneous determination of phenylglyoxylic acid (PGA), mandelic acid (MA), styrene glycol (SG) and hippuric acid (HA) in cell culture medium was developed. Analysis was performed on a C(18) column with a mobile phase composed of methanol-potassium dihydrogen phosphate (pH 2.5; 10 mM; 10:90, v/v) at 220 nm. The flow-rate of mobile phase was set at 0.5 mL/min. The mean absolute recoveries of PGA, MA, SG and HA were 95.9, 98.4, 98.0 and 97.1%, respectively. The inter-day and intra-day precisions, determined at three concentration levels, were less than 10% of RSD. The limits of quantification for PGA, MA, SG and HA were 13.2, 13.1, 14.5 and 11.2 microM with RSD less than 20%. The limits of detection for PGA, MA, SG and HA were 4.6, 4.6, 5.1 and 3.9 microM, respectively. The method was successfully applied to study the stereoselective metabolism of SG and MA in primary culture of rat hepatocytes. The results show that there is stereoselective metabolism for both of MA and SG in primary culture of rat hepatocytes. The extent of biotransformation from S-MA to PGA is significantly greater than that from the R enantiomer and the main metabolites are PGA and HA for S-SG and R-SG, respectively. (c) 2006 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17357177     DOI: 10.1002/bmc.783

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  3 in total

1.  An amino-functionalized mesoporous silica (KIT-6) as a sorbent for dispersive and ultrasonication-assisted micro solid phase extraction of hippuric acid and methylhippuric acid, two biomarkers for toluene and xylene exposure.

Authors:  Mohammad Behbahani; Saman Bagheri; Fariborz Omidi; Mostafa Mohammadpour Amini
Journal:  Mikrochim Acta       Date:  2018-10-11       Impact factor: 5.833

2.  A hydrogen peroxide-responsive hyperpolarized 13C MRI contrast agent.

Authors:  Alexander R Lippert; Kayvan R Keshari; John Kurhanewicz; Christopher J Chang
Journal:  J Am Chem Soc       Date:  2011-03-02       Impact factor: 15.419

3.  An approach based on liquid chromatography/electrospray ionization-mass spectrometry to detect diol metabolites as biomarkers of exposure to styrene and 1,3-butadiene.

Authors:  Shuijie Shen; Fan Zhang; Su Zeng; Jiang Zheng
Journal:  Anal Biochem       Date:  2008-12-14       Impact factor: 3.365

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.