Literature DB >> 17347762

Using deconvolution to improve PET spatial resolution in OSEM iterative reconstruction.

G Rizzo1, I Castiglioni, G Russo, M G Tana, F Dell'Acqua, M C Gilardi, F Fazio, S Cerutti.   

Abstract

OBJECTIVES: A novel approach to the PET image reconstruction is presented, based on the inclusion of image deconvolution during conventional OSEM reconstruction. Deconvolution is here used to provide a recovered PET image to be included as "a priori" information to guide OSEM toward an improved solution.
METHODS: Deconvolution was implemented using the Lucy-Richardson (LR) algorithm: Two different deconvolution schemes were tested, modifying the conventional OSEM iterative formulation: 1) We built a regularizing penalty function on the recovered PET image obtained by deconvolution and included it in the OSEM iteration. 2) After each conventional global OSEM iteration, we deconvolved the resulting PET image and used this "recovered" version as the initialization image for the next OSEM iteration. Tests were performed on both simulated and acquired data.
RESULTS: Compared to the conventional OSEM, both these strategies, applied to simulated and acquired data, showed an improvement in image spatial resolution with better behavior in the second case. In this way, small lesions, present on data, could be better discriminated in terms of contrast.
CONCLUSIONS: Application of this approach to both simulated and acquired data suggests its efficacy in obtaining PET images of enhanced quality.

Entities:  

Mesh:

Year:  2007        PMID: 17347762

Source DB:  PubMed          Journal:  Methods Inf Med        ISSN: 0026-1270            Impact factor:   2.176


  7 in total

1.  Comparison between two super-resolution implementations in PET imaging.

Authors:  Guoping Chang; Tinsu Pan; Feng Qiao; John W Clark; Osama R Mawlawi
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

2.  AI-based applications in hybrid imaging: how to build smart and truly multi-parametric decision models for radiomics.

Authors:  Isabella Castiglioni; Francesca Gallivanone; Paolo Soda; Michele Avanzo; Joseph Stancanello; Marco Aiello; Matteo Interlenghi; Marco Salvatore
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-07-11       Impact factor: 9.236

3.  Design and evaluation of an accurate CNR-guided small region iterative restoration-based tumor segmentation scheme for PET using both simulated and real heterogeneous tumors.

Authors:  Alpaslan Koç; Albert Güveniş
Journal:  Med Biol Eng Comput       Date:  2019-12-17       Impact factor: 2.602

4.  The importance of appropriate partial volume correction for PET quantification in Alzheimer's disease.

Authors:  Benjamin A Thomas; Kjell Erlandsson; Marc Modat; Lennart Thurfjell; Rik Vandenberghe; Sebastien Ourselin; Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-02-19       Impact factor: 9.236

5.  A method for model-free partial volume correction in oncological PET.

Authors:  Frank Hofheinz; Jens Langner; Jan Petr; Bettina Beuthien-Baumann; Liane Oehme; Jörg Steinbach; Jörg Kotzerke; Jörg van den Hoff
Journal:  EJNMMI Res       Date:  2012-04-24       Impact factor: 3.138

6.  Is SUVmax Helpful in the Differential Diagnosis of Enlarged Mediastinal Lymph Nodes? A Pilot Study.

Authors:  Congcong Yu; Xiaotian Xia; Chunxia Qin; Xun Sun; Yongxue Zhang; Xiaoli Lan
Journal:  Contrast Media Mol Imaging       Date:  2018-10-28       Impact factor: 3.161

7.  Partial volume correction for PET quantification and its impact on brain network in Alzheimer's disease.

Authors:  Jiarui Yang; Chenhui Hu; Ning Guo; Joyita Dutta; Lucia M Vaina; Keith A Johnson; Jorge Sepulcre; Georges El Fakhri; Quanzheng Li
Journal:  Sci Rep       Date:  2017-10-12       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.