BACKGROUND: At very early stages of acute myocardial infarction (AMI), highly sensitive biomarkers are still lacking. AIM: To evaluate the utility of human heart-type fatty acid-binding protein (h-FABP) for early diagnosis of AMI. DESIGN: Prospective diagnostic study. METHODS: Consecutive patients presenting to the emergency department with chest pain or dyspnoea within 24 h of symptom onset were included. At presentation, the h-FABP test result was compared to the standard diagnostic work-up, including repeated ECG and troponin T measurements. Sensitivity analysis was performed for inconclusive tests. RESULTS: We enrolled 280 patients presenting to hospital with a median symptom onset of 3 h (IQR 2-6 h): 109 (39%) had AMI. At presentation, h-FABP had a sensitivity of 69% (95%CI 59-77) and specificity of 74% (95%CI 66-80); 45 tests were false-positive and 34 were false-negative. Omitting inconclusive tests increased sensitivity and specificity only slightly. AMI was identified significantly earlier by h-FABP than by troponin T (24 vs. 8 patients, p=0.005). DISCUSSION: Although h-FABP can help to detect myocardial damage at an early stage in patients with chest pain or dyspnoea, it appears unsuitable as a stand-alone test for ruling out AMI.
BACKGROUND: At very early stages of acute myocardial infarction (AMI), highly sensitive biomarkers are still lacking. AIM: To evaluate the utility of humanheart-type fatty acid-binding protein (h-FABP) for early diagnosis of AMI. DESIGN: Prospective diagnostic study. METHODS: Consecutive patients presenting to the emergency department with chest pain or dyspnoea within 24 h of symptom onset were included. At presentation, the h-FABP test result was compared to the standard diagnostic work-up, including repeated ECG and troponin T measurements. Sensitivity analysis was performed for inconclusive tests. RESULTS: We enrolled 280 patients presenting to hospital with a median symptom onset of 3 h (IQR 2-6 h): 109 (39%) had AMI. At presentation, h-FABP had a sensitivity of 69% (95%CI 59-77) and specificity of 74% (95%CI 66-80); 45 tests were false-positive and 34 were false-negative. Omitting inconclusive tests increased sensitivity and specificity only slightly. AMI was identified significantly earlier by h-FABP than by troponin T (24 vs. 8 patients, p=0.005). DISCUSSION: Although h-FABP can help to detect myocardial damage at an early stage in patients with chest pain or dyspnoea, it appears unsuitable as a stand-alone test for ruling out AMI.
Authors: Jochen D Muehlschlegel; Tjörvi E Perry; Kuang-Yu Liu; Amanda A Fox; Charles D Collard; Stanton K Shernan; Simon C Body Journal: Anesth Analg Date: 2010-05-10 Impact factor: 5.108
Authors: Lakshmi Lavanya Reddy; Swarup A V Shah; Alpa J Dherai; Chandrashekhar K Ponde; Tester F Ashavaid Journal: Indian J Clin Biochem Date: 2015-03-14
Authors: Kyung Su Kim; Hui Jai Lee; Kyuseok Kim; You Hwan Jo; Tae Yun Kim; Jin Hee Lee; Joong Eui Rhee; Gil Joon Suh; Mi Ran Kim; Christopher C Lee; Adam J Singer Journal: J Korean Med Sci Date: 2010-12-22 Impact factor: 2.153