Literature DB >> 17345024

Proximal interphalangeal joint replacement with pyrolytic carbon prostheses.

Reinhard Meier1, Matthias Schulz, Hermann Krimmer, Nikolas Stütz, Ulrich Lanz.   

Abstract

OBJECTIVE: Prosthetic joint replacement to reduce pain and maintain function of the proximal interphalangeal joint. INDICATIONS: Symptomatic arthritis of the proximal interphalangeal joint with preservation of the collateral ligaments, sufficient bone support, and intact or at least reconstructable extensor tendons. CONTRAINDICATIONS: Lack of stability, e. g., as a result of rheumatoid arthritis or destruction of the ligaments caused by an accident. Nonreconstructable extensor tendons. Florid or chronic infection. Lack of patient compliance. SURGICAL TECHNIQUE: Dorsal approach to the proximal interphalangeal joint. A triangular tendinous flap with pedicle, based distally on the insertion of the medial band, is lifted up, leaving the lateral bands intact. The joint surfaces are resected while maintaining the palmar plate and the collateral ligaments. The trial prosthesis is fitted, its position is checked, and the final unconstrained prosthetic components are inserted using a press-fit technique. The dorsal aponeurosis is reapproximated.
RESULTS: 20 patients were treated for posttraumatic or idiopathic arthritis with 24 pyrolytic carbon PIP prostheses, and a follow-up examination was carried out after an average of 15 months (6-30 months). Surgical management was changed from arthroplasty to arthrodesis in three cases. For the remaining prostheses, an average range of motion of 50 degrees was achieved for the proximal interphalangeal joint. On the visual analog scale (VAS; 0: no pain, 10: incapacitating pain), the patients suffered few symptoms (VAS: 0-3). 80% of patients said they were satisfied with the outcome of the operation. In three cases (one infection, two dislocations) the prostheses had to be removed and arthrodesis performed. Migration of the distal components was observed on the radiographs in five cases, and of the proximal components in four cases, although this did not have any effect on the functional parameters. The development of a painless noise ("squeaking") was noticed in nine out of 21 prostheses. However, as with prosthetic migration, this did not cause any functional deficits.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17345024     DOI: 10.1007/s00064-007-1192-8

Source DB:  PubMed          Journal:  Oper Orthop Traumatol        ISSN: 0934-6694            Impact factor:   1.154


  13 in total

1.  Prosthetic hemi-arthroplasty for post-traumatic articular cartilage loss in the proximal interphalangeal joint.

Authors:  Mark Henry
Journal:  Hand (N Y)       Date:  2010-11-18

Review 2.  Advances in Proximal Interphalangeal Joint Arthroplasty: Biomechanics and Biomaterials.

Authors:  Andy F Zhu; Paymon Rahgozar; Kevin C Chung
Journal:  Hand Clin       Date:  2018-05       Impact factor: 1.907

3.  Proximal Interphalangeal Joint Replacement with Surface Replacement Arthroplasty (SR-PIP): Functional Results and Complications.

Authors:  Christina Luther; Guenter Germann; Michael Sauerbier
Journal:  Hand (N Y)       Date:  2009-12-02

4.  Radiographic interpretation of carpometacarpal arthroplasty: correlation between radiographic loosening and clinical outcome.

Authors:  Laurence Stillwater; Brett Memauri; Imran Ratanshi; Avinash Islur; Thelina Amaratunga
Journal:  Skeletal Radiol       Date:  2017-04-19       Impact factor: 2.199

Review 5.  A Systematic Review of Different Implants and Approaches for Proximal Interphalangeal Joint Arthroplasty.

Authors:  Michiro Yamamoto; Sunitha Malay; Yuki Fujihara; Lin Zhong; Kevin C Chung
Journal:  Plast Reconstr Surg       Date:  2017-05       Impact factor: 4.730

6.  Static versus dynamic splinting for proximal interphalangeal joint pyrocarbon implant arthroplasty: a comparison of current and historical cohorts.

Authors:  Jeanne M Riggs; Angela K Lyden; Kevin C Chung; Susan L Murphy
Journal:  J Hand Ther       Date:  2011-06-11       Impact factor: 1.950

7.  Reconstruction of swan neck deformities after proximal interphalangeal joint arthroplasty.

Authors:  John M Froelich; Marco Rizzo
Journal:  Hand (N Y)       Date:  2014-03

8.  Outcomes of pyrolytic carbon arthroplasty for the proximal interphalangeal joint.

Authors:  Kevin C Chung; Ashwin N Ram; Melissa J Shauver
Journal:  Plast Reconstr Surg       Date:  2009-05       Impact factor: 4.730

9.  Surface replacement arthroplasty of the proximal interphalangeal and metacarpophalangeal joints: The current state.

Authors:  Harvinder Singh; Joseph J Dias
Journal:  Indian J Plast Surg       Date:  2011-05

10.  A Novel Strategy for Preparation of Si-HA Coatings on C/C Composites by Chemical Liquid Vaporization Deposition/Hydrothermal Treatments.

Authors:  Xiong Xin-Bo; Ni Xin-Ye; Li Ya-Yun; Chu Cen-Cen; Zou Ji-Zhao; Zeng Xie-Rong
Journal:  Sci Rep       Date:  2016-08-05       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.