Literature DB >> 17335423

In vitro comparison of tibial plateau leveling osteotomy with and without use of a tibial plateau leveling jig.

Kay Ingo Schmerbach1, Christian Konrad Matthias Boeltzig, Ullrich Reif, Jan Carsten Wieser, Thomas Keller, Vera Grevel.   

Abstract

OBJECTIVE: To evaluate the influence of a tibial plateau leveling jig on osteotomy orientation, fragment reduction, and postoperative tibial plateau angle (TPA) during tibial plateau leveling osteotomy (TPLO). STUDY
DESIGN: In vitro experimental study. ANIMALS: Large-breed canine cadavers (n=20).
METHODS: TPLO was performed on 40 hindlimbs using 4 methods. Group 1: Jig; dogs in dorsal recumbency with the osteotomy parallel to the distal jig pin. Groups 2-4: No jig; dogs in lateral recumbency with the osteotomy in a vertical orientation (group 2: tibia parallel to the table top; group 3: controlled superimposition of the femoral condyles; group 4: internal rotation of the tibia). Postoperative TPA, fragment reduction, and osteotomy orientation relative to the tibial plateau were compared. Positive or negative values denoted deviation from parallel relative to the tibial plateau.
RESULTS: Postoperative TPA, fragment reduction, and proximodistal osteotomy orientation were not significantly different between groups. Craniocaudal osteotomy orientation was significantly different (P<.005) from the tibial plateau. Median deviations were -4.0 degrees (group 1), 11.8 degrees (group 2), 11.2 degrees (group 3), and 0.2 degrees (group 4). Group 1 was not significantly different from group 4.
CONCLUSIONS: A jig is not essential for osteotomy orientation, tibial plateau rotation, or fragment reduction. Comparable results were achieved performing a vertical osteotomy with the tibia slightly internally rotated (10 degrees -15 degrees) and parallel to the table surface. CLINICAL RELEVANCE: TPLO without use of a jig reduces surgical trauma, is less time consuming, and reduces cost.

Entities:  

Mesh:

Year:  2007        PMID: 17335423     DOI: 10.1111/j.1532-950X.2007.00248.x

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  4 in total

1.  Antimicrobial prophylaxis is considered sufficient to preserve an acceptable surgical site infection rate in clean orthopaedic and neurosurgeries in dogs.

Authors:  Kirsi Johanna Välkki; Katariina Hanne Thomson; Thomas Sven Christer Grönthal; Jouni Juho Tapio Junnila; Merja Hilma Johanna Rantala; Outi Maria Laitinen-Vapaavuori; Sari Helena Mölsä
Journal:  Acta Vet Scand       Date:  2020-09-17       Impact factor: 1.695

2.  Efficacy of a Customized Three-Dimensional Printing Surgical Guide for Tibial Plateau Leveling Osteotomy: A Comparison With Conventional Tibial Plateau Leveling Osteotomy.

Authors:  Jayon Kim; Jaeeun Ko; Jaehwan Kim; Anna Seo; Kidong Eom
Journal:  Front Vet Sci       Date:  2021-11-25

3.  Combining a joint health supplement with tibial plateau leveling osteotomy in dogs with cranial cruciate ligament rupture. An exploratory controlled trial.

Authors:  Filippo M Martini; Anna Brandstetter de Bellesini; Alda Miolo; Laura Del Coco; Francesco P Fanizzi; Antonio Crovace
Journal:  Int J Vet Sci Med       Date:  2017-10-06

4.  Intra-articular proximal jig pin placement during tibial plateau leveling osteotomy.

Authors:  Jacqueline V J Cavalcanti; Stanley E Kim; James Colee
Journal:  Open Vet J       Date:  2019-12-21
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.