Literature DB >> 17328827

Electrostatics and inhaled medications: influence on delivery via pressurized metered-dose inhalers and add-on devices.

Jolyon P Mitchell1, Dominic P Coppolo, Mark W Nagel.   

Abstract

The movement of inhaler-generated aerosols is significantly influenced by electrostatic charge on the particles and on adjacent surfaces. Particle charging arises in the aerosol formation process. Since almost all inhalers contain nonconducting components, these surfaces can also acquire charge during manufacture and use. Spacers and valved holding chambers used with pressurized metered-dose inhalers to treat obstructive lung diseases are particularly prone to this behavior, which increases variability in the amount of medication available for inhalation, and this is exacerbated by low ambient humidity. This may result in inconsistent medication delivery. Conditioning the device by washing it with a conductive surfactant (detergent) or using devices made of charge-dissipative/conducting materials can mitigate electrostatic charge. This review discusses sources of electrostatic charge, the processes that influence aerosol behavior, methods to mitigate electrostatic charge, and potential clinical implications.

Entities:  

Mesh:

Year:  2007        PMID: 17328827

Source DB:  PubMed          Journal:  Respir Care        ISSN: 0020-1324            Impact factor:   2.258


  5 in total

1.  Drug delivery systems in children.

Authors:  Stephen Lowis
Journal:  Paediatr Drugs       Date:  2008       Impact factor: 3.022

2.  The influence of actuator materials and nozzle designs on electrostatic charge of pressurised metered dose inhaler (pMDI) formulations.

Authors:  Yang Chen; Paul M Young; David F Fletcher; Hak Kim Chan; Edward Long; David Lewis; Tanya Church; Daniela Traini
Journal:  Pharm Res       Date:  2013-12-03       Impact factor: 4.200

3.  Design of a device for simultaneous particle size and electrostatic charge measurement of inhalation drugs.

Authors:  Kewu Zhu; Wai Kiong Ng; Shoucang Shen; Reginald B H Tan; Paul W S Heng
Journal:  Pharm Res       Date:  2008-07-01       Impact factor: 4.200

4.  The influence of flow rate on the aerosol deposition profile and electrostatic charge of single and combination metered dose inhalers.

Authors:  Susan Hoe; Daniela Traini; Hak-Kim Chan; Paul M Young
Journal:  Pharm Res       Date:  2009-10-06       Impact factor: 4.200

5.  A Retrospective Study of the Effectiveness of the AeroChamber Plus® Flow-Vu® Antistatic Valved Holding Chamber for Asthma Control.

Authors:  Chakkarin Burudpakdee; Vladimir Kushnarev; Dominic Coppolo; Jason A Suggett
Journal:  Pulm Ther       Date:  2017-07-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.