Daily monitoring of linear accelerator beam parameters using an amorphous silicon EPID.

G J Budgell1, R Zhang, R I Mackay.   

Abstract

An amorphous silicon EPID has been investigated to test its suitability as a daily check device for linac output and to provide daily monitoring of beam profile parameters such as flatness, symmetry, field size and wedge factor. Open and wedged 6 and 8 MV photon beams were collected on a daily basis for a period of just over a year and analysed in software to determine daily values of these parameters. Daily output results gave agreement between EPID measured dose and ion chamber measurements with a standard deviation of 0.65%. Step changes in flatness, symmetry and field size were readily detected by the EPID and could be correlated with adjustments made on service days and QC sessions. The results could also be used to assess the long term beam stability. Recalibration of the EPID required new baseline values of the parameters to be set. Wedge factors measured at one collimator angle proved stable but sensitive to changes in beam steering. The EPID proved to be a useful daily check device for linac output which can simultaneously be used for daily monitoring of beam profiles and field sizes.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17327658     DOI: 10.1088/0031-9155/52/6/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  An electronic portal image device (EPID)-based multiplatform rapid daily LINAC QA tool.

Authors:  Yangguang Ma; Xuemin Wang; Rizhen Mai; Tao Wang; Yuntong Pei; Shuaipeng Liu; Yuexin Guo
Journal:  J Appl Clin Med Phys       Date:  2021-01-07       Impact factor: 2.102

2.  Evaluation of application of EPID for rapid QC testing of linear accelerator.

Authors:  Shahla Ebrahimi Moghadam; Shahrokh Nasseri; Seyedeh Somayeh Seyedi; Hamid Gholamhosseinian; Mehdi Momennezhad
Journal:  Rep Pract Oncol Radiother       Date:  2018-08-13

3.  A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography.

Authors:  Christopher F Njeh; Blas Caroprese; Pushkar Desai
Journal:  Radiat Oncol       Date:  2012-03-27       Impact factor: 3.481

4.  Testing the portal imager GLAaS algorithm for machine quality assurance.

Authors:  G Nicolini; E Vanetti; A Clivio; A Fogliata; G Boka; L Cozzi
Journal:  Radiat Oncol       Date:  2008-05-21       Impact factor: 3.481

5.  Portal dosimetry in wedged beams.

Authors:  Hanno Spreeuw; Roel Rozendaal; Priscilla Camargo; Anton Mans; Markus Wendling; Igor Olaciregui-Ruiz; Jan-Jakob Sonke; Marcel Van Herk; Ben Mijnheer
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

6.  A proposed method for linear accelerator photon beam steering using EPID.

Authors:  Michael P Barnes; Frederick W Menk; Bishnu P Lamichhane; Peter B Greer
Journal:  J Appl Clin Med Phys       Date:  2018-07-26       Impact factor: 2.102

7.  Determination of the electronic portal imaging device pixel-sensitivity-map for quality assurance applications. Part 1: Comparison of methods.

Authors:  Michael Paul Barnes; Baozhou Sun; Brad Michael Oborn; Bishnu Lamichhane; Stuart Szwec; Matthew Schmidt; Bin Cai; Frederick Menk; Peter Greer
Journal:  J Appl Clin Med Phys       Date:  2022-04-15       Impact factor: 2.243

8.  Determination of dosimetric leaf gap using amorphous silicon electronic portal imaging device and its influence on intensity modulated radiotherapy dose delivery.

Authors:  S Timothy Peace Balasingh; I Rabi Raja Singh; K Mohamathu Rafic; S Ebenezer Suman Babu; B Paul Ravindran
Journal:  J Med Phys       Date:  2015 Jul-Sep
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.