Literature DB >> 17326914

[Effect of posture and positive end expiratory pressure on central venous pressure in patients with mechanical ventilation].

Bo Wang1, Yan Kang, Xiao-dong Jin, Zhi-cheng Qian, Liang Dong.   

Abstract

OBJECTIVE: To investigate the effect of posture and different positive end expiratory pressure (PEEP) on central venous pressure (CVP) in critically ill patients with mechanical ventilation (MV).
METHODS: Twenty-three critically ill patients were enrolled in this study with MV and CVP measurement in intensive care unit (ICU) from December 2005 to March 2006. CVP, heart rate (HR), mean arterial pressure (MAP), oxygen saturation of pulse (SpO(2)), and Riker's sedation-agitation score (SAS) were obtained simultaneously with a backrest elevation of 30 degree angle or with a supine flat position under different PEEP conditions of 0, 3, 6, 9, 12 and 15 cm H(2)O (1 cm H(2)O=0.098 kPa).
RESULTS: There were no differences in CVP, HR and MAP between the two positions at the same PEEP condition (all P>0.05). CVP increased gradually by the increment of PEEP with patients in both positions (all P<0.05), and significantly higher than other PEEP conditions when PEEP was 15 cm H(2)O. SpO(2) decreased and SAS increased when the position was adjusted from 30 degree angle to supination (both P<0.01), and when the mechanical ventilation was weaned, SpO(2) was the lowest than those at different PEEP conditions with patients in either position (all P<0.05). SAS decreased gradually by the increment of PEEP except at 15 cm H(2)O (all P<0.05). There were no differences in HR and MAP between different positions and in different PEEP conditions.
CONCLUSION: CVP was not influenced by the posture. CVP increased gradually with the increase in PEEP. Changing posture and weaning of mechanical ventilation led to deterioration of oxygenation and increased agitation. Maintaining of posture and PEEP when measuring CVP could improve safety and comfort of patients, and reduce the work of nursing.

Entities:  

Mesh:

Year:  2007        PMID: 17326914

Source DB:  PubMed          Journal:  Zhongguo Wei Zhong Bing Ji Jiu Yi Xue        ISSN: 1003-0603


  1 in total

1.  Optimal Transducer Level for Atrial and Pulmonary Arterial Pressure Measurement in Patients with Functional Single Ventricle.

Authors:  Yong-Hee Park; Da-Hye Yoo; Eun-Hee Kim; In-Kyung Song; Ji-Hyun Lee; Hee-Soo Kim; Woong-Han Kim; Jin-Tae Kim
Journal:  Pediatr Cardiol       Date:  2016-10-01       Impact factor: 1.655

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.