Literature DB >> 17326168

Inversion recovery prepared turbo spin echo sequences with reduced SAR using smooth transitions between pseudo steady states.

Matthias Weigel1, Maxim Zaitsev, Juergen Hennig.   

Abstract

This study investigates the contrast behavior of 2D inversion recovery (IR) prepared turbo spin echo (TSE) sequences that use RF pulse schemes with variable low flip angles (hyperTSE) to reduce RF power deposition. A framework of equations and calculations for adapting the sequence parameters is presented by which equivalent image contrast is achieved compared to conventional IR-TSE imaging. Although the inversion time (TI) and repetition time (TR) do not need to be changed, the echo time (TE) has to be prolonged such that the effective TE (TE(eff)) is preserved. Measurements in healthy volunteers confirmed this finding for IR-TSE sequences using different TIs: fluid attenuated inversion recovery (FLAIR), gray matter (GM)-white matter (WM)-IR, and short tau IR (STIR). The results demonstrate that hyperTSE sequences enable high-quality IR-prepared imaging with a considerably reduced specific absorption rate (SAR).

Mesh:

Year:  2007        PMID: 17326168     DOI: 10.1002/mrm.21170

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Hyperecho-turbo spin-echo sequences at 3T: clinical application in neuroradiology.

Authors:  R H Tetzlaff; I Mader; W Küker; J Weber; S Ziyeh; A Schulze-Bonhage; J Hennig; M Weigel
Journal:  AJNR Am J Neuroradiol       Date:  2008-03-05       Impact factor: 3.825

2.  [Problems and chances of high field magnetic resonance imaging].

Authors:  M E Ladd; M Bock
Journal:  Radiologe       Date:  2013-05       Impact factor: 0.635

3.  Comparison of BOLD and CBV using 3D EPI and 3D GRASE for cortical layer functional MRI at 7 T.

Authors:  Alexander J S Beckett; Tetiana Dadakova; Jennifer Townsend; Laurentius Huber; Suhyung Park; David A Feinberg
Journal:  Magn Reson Med       Date:  2020-06-18       Impact factor: 4.668

Review 4.  (19)F MRI for quantitative in vivo cell tracking.

Authors:  Mangala Srinivas; Arend Heerschap; Eric T Ahrens; Carl G Figdor; I Jolanda M de Vries
Journal:  Trends Biotechnol       Date:  2010-04-26       Impact factor: 19.536

5.  Fast T2 mapping using multi-echo spin-echo MRI: A linear order approach.

Authors:  Yaghoub Fatemi; Habibollah Danyali; Mohammad Sadegh Helfroush; Houshang Amiri
Journal:  Magn Reson Med       Date:  2020-05-19       Impact factor: 4.668

6.  Wireless coils based on resonant and nonresonant coupled-wire structure for small animal multinuclear imaging.

Authors:  Tania S Vergara Gomez; Marc Dubois; Stanislav Glybovski; Benoit Larrat; Julien de Rosny; Carsten Rockstuhl; Monique Bernard; Redha Abdeddaim; Stefan Enoch; Frank Kober
Journal:  NMR Biomed       Date:  2019-02-17       Impact factor: 4.044

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.