Literature DB >> 17326167

Reduced field-of-view MRI using outer volume suppression for spinal cord diffusion imaging.

B J Wilm1, J Svensson, A Henning, K P Pruessmann, P Boesiger, S S Kollias.   

Abstract

A spin-echo single-shot echo-planar imaging (SS-EPI) technique with a reduced field of view (FOV) in the phase-encoding direction is presented that simultaneously reduces susceptibility effects and motion artifacts in diffusion-weighted (DW) imaging (DWI) of the spinal cord at a high field strength (3T). To minimize aliasing, an outer volume suppression (OVS) sequence was implemented. Effective fat suppression was achieved with the use of a slice-selection gradient-reversal technique. The OVS was optimized by numerical simulations with respect to T(1) relaxation times and B(1) variations. The optimized sequence was evaluated in vitro and in vivo. In simulations the optimized OVS showed suppression to <0.25% and approximately 3% in an optimal and worst-case scenario, respectively. In vitro measurements showed a mean residual signal of <0.95% +/- 0.42 for all suppressed areas. In vivo acquisition with 0.9 x 1.05 mm(2) in-plane resolution resulted in artifact-free images. The short imaging time of this technique makes it promising for clinical studies.

Mesh:

Year:  2007        PMID: 17326167     DOI: 10.1002/mrm.21167

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  67 in total

1.  Free-breathing inner-volume black-blood imaging of the human heart using two-dimensionally selective local excitation at 3 T.

Authors:  Khaled Z Abd-Elmoniem; Christoph Barmet; Matthias Stuber
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

2.  Diffusion tensor imaging of the normal pediatric spinal cord using an inner field of view echo-planar imaging sequence.

Authors:  N Barakat; F B Mohamed; L N Hunter; P Shah; S H Faro; A F Samdani; J Finsterbusch; R Betz; J Gaughan; M J Mulcahey
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-02       Impact factor: 3.825

Review 3.  Examination of spinal cord tissue architecture with magnetic resonance diffusion tensor imaging.

Authors:  Stephan E Maier
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

4.  Diffusion tensor imaging of ex vivo cervical spinal cord specimens: the immediate and long-term effects of fixation on diffusivity.

Authors:  T H Kim; L Zollinger; X F Shi; J Rose; E-K Jeong
Journal:  Anat Rec (Hoboken)       Date:  2009-02       Impact factor: 2.064

5.  3T diffusion-weighted MRI of the thyroid gland with reduced distortion: preliminary results.

Authors:  V Taviani; S Nagala; A N Priest; M A McLean; P Jani; M J Graves
Journal:  Br J Radiol       Date:  2013-06-14       Impact factor: 3.039

6.  Variable flip angle three-dimensional fast spin-echo sequence combined with outer volume suppression for imaging trabecular bone structure of the proximal femur.

Authors:  Misung Han; Ko Chiba; Suchandrima Banerjee; Julio Carballido-Gamio; Roland Krug
Journal:  J Magn Reson Imaging       Date:  2014-06-23       Impact factor: 4.813

Review 7.  Spinal cord MRI in multiple sclerosis--diagnostic, prognostic and clinical value.

Authors:  Hugh Kearney; David H Miller; Olga Ciccarelli
Journal:  Nat Rev Neurol       Date:  2015-05-26       Impact factor: 42.937

8.  Assessment of tumor morphology on diffusion-weighted (DWI) breast MRI: Diagnostic value of reduced field of view DWI.

Authors:  Maarten W Barentsz; Valentina Taviani; Jung M Chang; Debra M Ikeda; Kanae K Miyake; Suchandrima Banerjee; Maurice A A J van den Bosch; Brian A Hargreaves; Bruce L Daniel
Journal:  J Magn Reson Imaging       Date:  2015-04-24       Impact factor: 4.813

9.  Real-time MR thermometry for monitoring HIFU ablations of the liver.

Authors:  Andrew B Holbrook; Juan M Santos; Elena Kaye; Viola Rieke; Kim Butts Pauly
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

10.  Quantifying the impact of underlying measurement error on cervical spinal cord diffusion tensor imaging at 3T.

Authors:  Samantha By; Alex K Smith; Lindsey M Dethrage; Bailey D Lyttle; Bennett A Landman; Jeffrey L Creasy; Siddharama Pawate; Seth A Smith
Journal:  J Magn Reson Imaging       Date:  2016-05-18       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.