| Literature DB >> 17323050 |
Casper W Bollen1, Cuno S P M Uiterwaal, Adrianus J van Vught.
Abstract
OBJECTIVE: There is considerable heterogeneity among randomized trials comparing high-frequency ventilation (HFV) with conventional mechanical ventilation (CMV) in premature neonates with respiratory distress syndrome. We investigated what factors explained differences in outcome among these trials.Entities:
Mesh:
Year: 2007 PMID: 17323050 PMCID: PMC1915647 DOI: 10.1007/s00134-007-0545-y
Source DB: PubMed Journal: Intensive Care Med ISSN: 0342-4642 Impact factor: 17.440
Study characteristics
| Reference | Year | Time on CMV | Age | Birth weight | SensorM | HLVS | LPVS | Surf | CLD lnRR | Weight | Death or CLD lnRR | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| [ | 1992 | 9.0 | 28 | 1.100 | Y | Y | N | N | -1.29 | 0.01 | -0.58 | 0.01 |
| [ | 1996 | 3.0 | 31 | 1.500 | Y | Y | N | Y | -0.67 | 0.04 | -0.55 | 0.02 |
| [ | 1996 | 7.2 | 27 | 0.950 | N | N | N | Y | 0.02 | 0.01 | -0.23 | 0.10 |
| [ | 1997 | 8.0 | 27 | 1.020 | N | Y | N | Y | -0.70 | 0.03 | 0.48 | 0.03 |
| [ | 1998 | 1.0 | 28 | 1.100 | N | N | N | Y | 0.00 | 0.00 | 0.31 | 0.00 |
| [ | 1999 | 26 | 0.850 | Y | Y | N | Y | -1.03 | 0.01 | -0.74 | 0.01 | |
| [ | 1999 | 0.5 | 27 | 0.870 | N | Y | Y | Y | 0.09 | 0.06 | 0.01 | 0.04 |
| [ | 2001 | 2.6 | 26 | 0.840 | Y | Y | Y | Y | -0.98 | 0.02 | -0.59 | 0.02 |
| [ | 2001 | 0.3 | 28 | 0.990 | N | Y | Y | Y | -0.20 | 0.05 | -0.06 | 0.05 |
| [ | 2002 | 2.7 | 26 | 0.850 | Y | Y | Y | Y | -0.06 | 0.16 | -0.22 | 0.13 |
| [ | 2002 | 1.0 | 26 | 0.850 | N | Y | Y | Y | -0.01 | 0.54 | -0.02 | 0.60 |
| [ | 2003 | 1.0 | 29 | 1.200 | Y | Y | Y | Y | 0.32 | 0.03 | 0.27 | 0.04 |
| [ | 2003 | 14.0 | 27 | 0.980 | Y | Y | Y | Y | -0.04 | 0.05 | ||
| [ | 2003 | 26 | 0.726 | N | Y | Y | Y | 0.10 | 0.05 | 0.09 | 0.03 | |
| [ | 2005 | 0.3 | 27 | 0.880 | N | Y | Y | Y | -1.44 | 0.01 | -1.20 | 0.00 |
Year: year of publication. Time CMV: Mean time on CMV before start of the study in hours. Age: Mean gestational age (weeks). Birth weight: mean birth weight (kg). HLVS: high lung volume strategy in the HFV group, LPVS: lung protective ventilation strategy in the CMV group, Surf: use of surfactant in the study. CLD: chronic lung disease, defined as on oxygen at 30–36 weeks postmenstrual age, LnRR: natural log of the relative risk
Fig. 1Funnel plot. Selection bias in reporting RR of chronic lung disease (CLD) as suggested by asymmetry of the distribution of studies. x-axis: inverse of the standard error of the RR; y-axis: natural logarithm of the RR. Blue diamonds: studies with either no high lung volume strategy (HLVS) or no lung protective volume strategy (LPVS); pink diamonds: studies with both HLVS and LPVS; dotted line: estimated pooled RR including all studies; dashed colored lines: pooled RR of subgroups of studies. Publication bias was visually appraised by assessing symmetry of distribution of studies around the lines of pooled estimates. CMV conventional mechanical ventilation
Fig. 2Linear regression analyses. Crude and subgroup linear regression analyses of the effect of year of publication, prior time on CMV and gestational age with natural logarithm of RR of CLD as dependent variable. y-axis: natural logarithm of the RR; x-axis: explanatory variables. Blue diamonds: studies with either no HLVS or no LPVS; pink diamonds: studies with both HLVS and LPVS. The size of the diamonds reflects the weights the individual trials contribute to the analyses. Thin blue line: regression line including all studies; thick pink line: regression line including only studies with both HLVS and LPVS. CMV conventional mechanical ventilation
Fig. 3Same as Fig. 2
Fig. 4Same as Fig. 2
Univariable linear regression analysis
| 95% confidence interval | 95% confidence interval | ||||||
|---|---|---|---|---|---|---|---|
| Crude B | Sig. | Lower | Upper | RRR | Lower | Upper | |
| boundary | boundary | boundary | boundary | ||||
| Year | 0.09 | 0.025 | 0.01 | 0.16 | 3.13 | 1.18 | 8.27 |
| SensorM | -0.17 | 0.351 | -0.55 | 0.21 | 0.84 | 0.58 | 1.24 |
| (no to yes) | |||||||
| TimeCMV | -0.09 | 0.055 | -0.19 | 0.00 | 0.44 | 0.19 | 1.02 |
| Age | -0.08 | 0.237 | -0.23 | 0.06 | 0.66 | 0.32 | 1.36 |
| Weight | -0.76 | 0.163 | -1.87 | 0.35 | 0.54 | 0.22 | 1.33 |
| HLVS | -0.11 | 0.883 | -1.74 | 1.52 | 0.89 | 0.17 | 4.57 |
| LPVS | 0.64 | 0.009 | 0.19 | 1.10 | 1.91 | 1.21 | 3.00 |
| Surf | 1.21 | 0.168 | -0.59 | 3.00 | 3.34 | 0.56 | 20.03 |
| CMV | -0.18 | 0.774 | -1.53 | 1.17 | 0.90 | 0.42 | 1.92 |
| Year | 0.05 | 0.096 | -0.01 | 0.12 | 2.01 | 0.86 | 4.65 |
| SensorM | -0.17 | 0.132 | -0.39 | 0.06 | 0.85 | 0.67 | 1.06 |
| TimeCMV | -0.01 | 0.590 | -0.05 | 0.03 | 0.92 | 0.65 | 1.29 |
| Age | -0.02 | 0.733 | -0.13 | 0.10 | 0.91 | 0.52 | 1.61 |
| Weight | -0.22 | 0.611 | -1.16 | 0.71 | 0.84 | 0.40 | 1.77 |
| HLVS | -0.37 | 0.698 | -2.44 | 1.69 | 0.69 | 0.09 | 5.45 |
| LPVS | 0.19 | 0.275 | -0.18 | 0.56 | 1.21 | 0.84 | 1.76 |
| Surf | 0.52 | 0.289 | -0.51 | 1.56 | 1.69 | 0.60 | 4.75 |
| CMV | -0.02 | 0.963 | -0.91 | 0.87 | 0.99 | 0.60 | 1.63 |
| Year | 0.00 | 0.971 | -0.23 | 0.22 | 0.96 | 0.05 | 17.34 |
| TimeCMV | -0.05 | 0.698 | -0.34 | 0.25 | 0.66 | 0.05 | 8.75 |
| Age | 0.04 | 0.727 | -0.22 | 0.30 | 1.22 | 0.33 | 4.49 |
| Weight | 0.41 | 0.693 | -1.99 | 2.81 | 1.38 | 0.20 | 9.44 |
| Year | 0.01 | 0.846 | -0.15 | 0.17 | 1.20 | 0.15 | 9.72 |
| TimeCMV | 0.00 | 0.819 | -0.05 | 0.04 | 0.96 | 0.65 | 1.43 |
| Age | 0.06 | 0.406 | -0.10 | 0.21 | 1.34 | 0.61 | 2.92 |
| Weight | 0.55 | 0.396 | -0.89 | 1.99 | 1.55 | 0.49 | 4.90 |
Simple linear regression analyses were calculated for chronic lung disease (CLD), defined as on oxygen at 30–36 weeks postgestational age, and death or CLD. The following co-variates were evaluated: Year: Number of years after the first included study; SensorM: Whether or not a Sensormedics type of HFV was used; TimeCMV: Mean time on CMV before start of the study in hours; Age: Mean gestational age (weeks); Weight: mean birth weight (kg); HLVS: high lung volume strategy in the HFV group; LPVS: lung protective ventilation strategy in the CMV group; Surf: use of surfactant in the study; B was the estimated crude coefficient; RRR: relative risk ratio = RRcovariate=1/RRcovariate=0, for binary variables (SensorM, HLVS and LPVS), for continues variables the extreme values reported in the studies were used to calculate the ranges, 13 for years, 8.7 for Time on CMV, 5 for Age, 0.8 for Weight and 0.65 for CMV (RRRyears = RRyear=2005/RRyear=1992, RRRtime on CMV = RRtime=9 h/RRtime=0.3 h, RRRage = RRage=31 weeks/RRyear=26 weeks, RRRweight = RRweight=1.5 kg/RRyear=0.7 kg, RRRincidence of CLD in CMV=0.75/RRincidence=0.08)
Fig. 5Linear regression analysis of incidence of CLD in CMV on incidence of CLD in HFV. y-axis: incidence of CLD in HFV; x-axis: incidence of CLD in CMV. Thin pink line: regression line including all studies
Multivariable linear regression analysis
| Adjusted | 95% confidence interval | 95% confidence interval | |||||
|---|---|---|---|---|---|---|---|
| B | Sig. | Lower boundary | Upper boundary | RRR | Lower boundary | Upper boundary | |
| (Constant) | -0.66 | 0.900 | -13.03 | 11.70 | |||
| SensorM | -0.04 | 0.884 | -0.75 | 0.66 | 0.96 | 0.47 | 1.94 |
| TimeCMV | -0.02 | 0.903 | -0.38 | 0.34 | 0.85 | 0.04 | 19.22 |
| Age | 0.03 | 0.850 | -0.36 | 0.42 | 1.17 | 0.16 | 8.32 |
| HLVS | -0.88 | 0.306 | -2.80 | 1.04 | 0.42 | 0.06 | 2.84 |
| LPVS | 0.70 | 0.506 | -1.73 | 3.14 | 2.02 | 0.18 | 23.12 |
| (Constant) | -1.86 | 0.412 | -7.22 | 3.49 | |||
| SensorM | -0.17 | 0.309 | -0.55 | 0.21 | 0.85 | 0.58 | 1.24 |
| TimeCMV | 0.01 | 0.722 | -0.05 | 0.06 | 1.07 | 0.68 | 1.69 |
| Age | 0.08 | 0.299 | -0.09 | 0.25 | 1.47 | 0.62 | 3.47 |
| HLVS | -0.88 | 0.407 | -3.38 | 1.62 | 0.42 | 0.03 | 5.06 |
| LPVS | 0.68 | 0.127 | -0.28 | 1.65 | 1.98 | 0.76 | 5.19 |
| (Constant) | 0.07 | 0.904 | -1.21 | 1.35 | |||
| SensorM | -0.06 | 0.698 | -0.38 | 0.26 | 0.94 | 0.69 | 1.30 |
| HLVS | -0.81 | 0.203 | -2.14 | 0.52 | 0.44 | 0.12 | 1.68 |
| LPVS | 0.72 | 0.011 | 0.21 | 1.23 | 2.06 | 1.23 | 3.43 |
| (Constant) | |||||||
| SensorM | -0.11 | 0.318 | -0.33 | 0.12 | 0.90 | 0.72 | 1.13 |
| HLVS | -0.79 | 0.363 | -2.66 | 1.08 | 0.45 | 0.07 | 2.93 |
| LPVS | 0.46 | 0.089 | -0.09 | 1.01 | 1.59 | 0.92 | 2.74 |
Multiple linear regression analyses were calculated for chronic lung disease (CLD), defined as on oxygen at 30-36 weeks postgestational age, and death or CLD. The following co-variates were evaluated: SensorM whether or not a Sensormedics type of HFV was used; TimeCMV mean time on CMV before start of the study (in hours). HLVS high lung volume strategy in the HFV group, LPVS lung protective ventilation strategy in the CMV group. B was the adjusted estimated coefficient. RRR relative risk ratio=RRcovariate=1/RRcovariate=0, for binary variables (SensorM, HLVS and LPVS), for continues variables the extreme values reported in the studies were used, 8.7 for Time on CMV (RRRage = RRage=31 weeks/RRyear=26 weeks)