Meta-analysis of accommodating intraocular lenses.

Oliver Findl1, Christina Leydolt.   

Abstract

Accommodating intraocular lenses (IOLs) based on the concept of optic shift were introduced to restore accommodation after cataract surgery. Currently, 3 types of accommodating IOLs are commercially available: 1CU (HumanOptics), BioComFold (Morcher), and AT-45 Crystalens (eyeonics, Inc.). We present a meta-analysis of the peer-reviewed data from studies of these IOLs that use optic-shift measurements and visual acuity as the main outcome measures. In the 6 randomized controlled studies, 5 of which studied the 1CU IOL, the visual acuity results showed moderate to no improvement in near visual acuity compared with control IOLs and a statistically significant but small and inter-patient variable anterior shift of the IOL optic after pilocarpine stimulation. More clinical trials with randomized, controlled, and patient- and examiner-masked study designs that follow the guidelines of evidence-based medicine are needed to prove a benefit of accommodating focus-shift IOLs.

Entities:  

Mesh:

Year:  2007        PMID: 17321405     DOI: 10.1016/j.jcrs.2006.11.020

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  23 in total

Review 1.  [Apodized diffractive optic. New concept in multifocal lens technology].

Authors:  T Kohnen; V Derhartunian
Journal:  Ophthalmologe       Date:  2007-10       Impact factor: 1.059

Review 2.  [Accommodation and presbyopia : part 2: surgical procedures for the correction of presbyopia].

Authors:  M Baumeister; T Kohnen
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

3.  [Evaluation and quality assurance of refractive surgery procedures by the German Ophthalmological Society and the Professional Association of German Ophthalmologists. Status: May 2011].

Authors:  T Kohnen; T Neuhann; M Knorz
Journal:  Ophthalmologe       Date:  2011-09       Impact factor: 1.059

4.  Ciliary muscle thickness profiles derived from optical coherence tomography images.

Authors:  Sandra Wagner; Eberhart Zrenner; Torsten Strasser
Journal:  Biomed Opt Express       Date:  2018-10-01       Impact factor: 3.732

Review 5.  Clinical application of accommodating intraocular lens.

Authors:  You-Ling Liang; Song-Bai Jia
Journal:  Int J Ophthalmol       Date:  2018-06-18       Impact factor: 1.779

6.  Contrast sensitivity with bifocal intraocular lenses is halved, as measured with the Freiburg Vision Test (FrACT), yet patients are happy.

Authors:  Alexandra Anton; Daniel Böhringer; Michael Bach; Thomas Reinhard; Florian Birnbaum
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-01-17       Impact factor: 3.117

Review 7.  [The basics of refractive lens exchange].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

8.  Objective accommodation measurements in pseudophakic subjects using an autorefractor and an aberrometer.

Authors:  Dorothy M Win-Hall; Adrian Glasser
Journal:  J Cataract Refract Surg       Date:  2009-02       Impact factor: 3.351

9.  Intraocular lenses for the treatment of age-related cataracts: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2009-10-01

Review 10.  Cataract surgery with implantation of an artificial lens.

Authors:  Thomas Kohnen; Martin Baumeister; Daniel Kook; Oliver K Klaproth; Christian Ohrloff
Journal:  Dtsch Arztebl Int       Date:  2009-10-23       Impact factor: 5.594

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.