Literature DB >> 17321158

Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique.

Maxwell C Park1, James E Tibone, Neal S ElAttrache, Christopher S Ahmad, Bong-Jae Jun, Thay Q Lee.   

Abstract

We hypothesized that a transosseous-equivalent repair would demonstrate improved tensile strength and gap formation between the tendon and tuberosity when compared with a double-row technique. In 6 fresh-frozen human shoulders, a transosseous-equivalent rotator cuff repair was performed: a suture limb from each of two medial anchors was bridged over the tendon and fixed laterally with an interference screw. In 6 contralateral matched-pair specimens, a double-row repair was performed. For all repairs, a materials testing machine was used to load each repair cyclically from 10 N to 180 N for 30 cycles; each repair underwent tensile testing to measure failure loads at a deformation rate of 1 mm/sec. Gap formation between the tendon edge and insertion was measured with a video digitizing system. The mean ultimate load to failure was significantly greater for the transosseous-equivalent technique (443.0 +/- 87.8 N) compared with the double-row technique (299.2 +/- 52.5 N) (P = .043). Gap formation during cyclic loading was not significantly different between the transosseous-equivalent and double-row techniques, with mean values of 3.74 +/- 1.51 mm and 3.79 +/- 0.68 mm, respectively (P = .95). Stiffness for all cycles was not statistically different between the two constructs (P > .40). The transosseous-equivalent rotator cuff repair technique improves ultimate failure loads when compared with a double-row technique. Gap formation is similar for both techniques. A transosseous-equivalent repair helps restore footprint dimensions and provides a stronger repair than the double-row technique, which may help optimize healing biology.

Entities:  

Mesh:

Year:  2007        PMID: 17321158     DOI: 10.1016/j.jse.2006.09.011

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  77 in total

1.  Medial versus lateral supraspinatus tendon properties: implications for double-row rotator cuff repair.

Authors:  Vincent M Wang; Fan Chia Wang; Allison G McNickle; Nicole A Friel; Adam B Yanke; Susan Chubinskaya; Anthony A Romeo; Nikhil N Verma; Brian J Cole
Journal:  Am J Sports Med       Date:  2010-10-07       Impact factor: 6.202

2.  Influence of the initial rupture size and tendon subregion on three-dimensional biomechanical properties of single-row and double-row rotator cuff reconstructions.

Authors:  O Lorbach; D Pape; F Raber; L C Busch; D Kohn; M Kieb
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-11       Impact factor: 4.342

3.  The effects of low-intensity pulsed ultrasound on tendon-bone healing in a transosseous-equivalent sheep rotator cuff model.

Authors:  Vedran Lovric; Michael Ledger; Jerome Goldberg; Wade Harper; Nicky Bertollo; Matthew H Pelletier; Rema A Oliver; Yan Yu; William R Walsh
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-31       Impact factor: 4.342

Review 4.  Single versus double-row repair of the rotator cuff: does double-row repair with improved anatomical and biomechanical characteristics lead to better clinical outcome?

Authors:  Stephan Pauly; Christian Gerhardt; Jianhai Chen; Markus Scheibel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-08-25       Impact factor: 4.342

5.  Preliminary investigation of a biological augmentation of rotator cuff repairs using a collagen implant: a 2-year MRI follow-up.

Authors:  Desmond John Bokor; David Sonnabend; Luke Deady; Ben Cass; Allan Young; Craig Van Kampen; Steven Arnoczky
Journal:  Muscles Ligaments Tendons J       Date:  2015-10-20

Review 6.  [Rotator cuff repair: single- vs double-row. Clinical and biomechanical results].

Authors:  M H Baums; T Kostuj; H-M Klinger; R Papalia
Journal:  Orthopade       Date:  2016-02       Impact factor: 1.087

7.  Suture slippage in knotless suture anchors resulting in subacromial-subdeltoid bursitis.

Authors:  Mohammad Reza Hayeri; Daniel T Keefe; Eric Y Chang
Journal:  Skeletal Radiol       Date:  2016-01-06       Impact factor: 2.199

Review 8.  [Rotator cuff avulsion fractures. Current concepts in the surgical treatment].

Authors:  S Pauly; M Scheibel
Journal:  Orthopade       Date:  2016-02       Impact factor: 1.087

9.  Single-row versus double-row arthroscopic repair in the treatment of rotator cuff tears: a prospective randomized clinical study.

Authors:  Ignacio Carbonel; Angel Antonio Martinez; Angel Calvo; Jorge Ripalda; Antonio Herrera
Journal:  Int Orthop       Date:  2012-05-16       Impact factor: 3.075

10.  Arthroscopic refixation of a combined fracture of the greater and lesser tuberosity of the proximal humerus.

Authors:  S Pauly; S Herrmann; C Perka; S Greiner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-12       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.