Literature DB >> 17320892

Determination of biogenic amines in alcoholic beverages by ion chromatography with suppressed conductivity detection and integrated pulsed amperometric detection.

Brian M De Borba1, Jeff S Rohrer.   

Abstract

The determination of biogenic amines in alcoholic beverages is important to assess the potential risks associated with the consumption of high concentrations of these compounds. In addition, product storage conditions and the length of storage can cause the formation of biogenic amines that reduce product quality. We report a new method using cation-exchange chromatography with either suppressed conductivity, integrated pulsed amperometry, UV, or a combination of these detection techniques to determine biogenic amines in alcoholic beverages. The main objective was to provide a direct comparison between IPAD and suppressed conductivity detection for determining biogenic amines in alcoholic beverages. Suppressed conductivity is the simplest detection approach for determining putrescine, cadaverine, histamine, agmatine, phenylethylamine, spermidine, and spermine with good sensitivity (0.004-0.08 mg/l) and was used to evaluate the influence of storage time and conditions on the evolution of biogenic amines in alcoholic beverages. Integrated pulsed amperometric detection (IPAD) detects more biogenic amines than suppressed conductivity detection, enabling the detection of dopamine, tyramine, and serotonin. Tyramine was simultaneously determined by UV detection and IPAD to provide confirmation and ensure the accuracy of the analytical results. The linearity of biogenic amine responses was within 0.1-20 mg/l and peak area precisions were 0.24-4.97% for IPAD, suppressed conductivity-IPAD, and UV detection. The sensitivity for the 10 biogenic amines using the 3 detection techniques varied considerably from 0.004-1.1 mg/l and recoveries were within 85-122%.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17320892     DOI: 10.1016/j.chroma.2007.01.114

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

1.  The Effects of Different Processing Methods on the Levels of Biogenic Amines in Zijuan Tea.

Authors:  Dandan Liu; Kang Wang; Xiaoran Xue; Qiang Wen; Shiwen Qin; Yukai Suo; Mingzhi Liang
Journal:  Foods       Date:  2022-04-27

2.  Focused review: agmatine in fermented foods.

Authors:  Fernanda Galgano; Marisa Caruso; Nicola Condelli; Fabio Favati
Journal:  Front Microbiol       Date:  2012-06-07       Impact factor: 5.640

3.  Level of Biogenic Amines in Red and White Wines, Dietary Exposure, and Histamine-Mediated Symptoms upon Wine Ingestion.

Authors:  Francesco Esposito; Paolo Montuori; Mario Schettino; Salvatore Velotto; Tommaso Stasi; Raffaele Romano; Teresa Cirillo
Journal:  Molecules       Date:  2019-10-08       Impact factor: 4.411

4.  Amperometric Biosensor Based on Diamine Oxidase/Platinum Nanoparticles/Graphene/Chitosan Modified Screen-Printed Carbon Electrode for Histamine Detection.

Authors:  Irina Mirela Apetrei; Constantin Apetrei
Journal:  Sensors (Basel)       Date:  2016-03-24       Impact factor: 3.576

5.  Liquid Chromatographic Determination of Biogenic Amines in Fish Based on Pyrene Sulfonyl Chloride Pre-Column Derivatization.

Authors:  Elvira S Plakidi; Niki C Maragou; Marilena E Dasenaki; Nikolaos C Megoulas; Michael A Koupparis; Nikolaos S Thomaidis
Journal:  Foods       Date:  2020-05-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.