A comparison of LightSpeed LS1 and LightSpeed LSX NiTi rotary instruments in apical transportation and length control in simulated root canals.

Mian K Iqbal1, Brian Banfield, Amanda Lavorini, Benedict Bachstein.   

Abstract

In a major design change LightSpeed Technologies Inc. has replaced the U-shape blade design with a spade-shape design in LightSpeed LSX root canal rotary instruments. A double-digital radiographic technique was used to compare apical transportation (AT) and length control (LC) between the two instrument designs. Thirty simulated plastic root canals were instrumented by each rotary system. Digital radiography and AutoCAD 2007 were used to determine the central axes of files at 20, 35, 50, and 70 ISO sizes. By superimposition of central axes with a baseline at size 20, the degree of AT was measured at 0, 1, and 3 mm from working length (WL). The distance from file tips to set WL indicated any loss of LC. ANOVA test showed no significant differences between groups with respect to the degree of AT or LC. No instrument separation was noted. The results indicate that newly designed Lightspeed LSX instruments maintain the same effectiveness regarding AT and LC as that of the LightSpeed LS1 instruments.

Mesh:

Substances:

Year:  2007        PMID: 17320711     DOI: 10.1016/j.joen.2006.10.013

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  4 in total

1.  Computed Tomographic Evaluation of K3 Rotary and Stainless Steel K File Instrumentation in Primary Teeth.

Authors:  Haridoss Selvakumar; Swaminathan Kavitha; Eapen Thomas; Vasanthakumari Anadhan; Rajendran Vijayakumar
Journal:  J Clin Diagn Res       Date:  2016-01-01

2.  Canal-centering ability: An endodontic challenge.

Authors:  Deivanayagam Kandaswamy; Nagendrababu Venkateshbabu; Ilango Porkodi; Gali Pradeep
Journal:  J Conserv Dent       Date:  2009-01

3.  Evaluation of surface preparation and maintenance of canal curvature following instrumentation with hand 'K' file and three different Ni-Ti rotary systems: A radiographic and SEM study.

Authors:  Namrata Bhatti; Renu Sroa; Vimal K Sikri
Journal:  Contemp Clin Dent       Date:  2010-04

4.  Comparison of working length control consistency between hand K-files and Mtwo NiTi rotary system.

Authors:  Károly Krajczár; Enikő Varga; Gyula Marada; Sára Jeges; Vilmos Tóth
Journal:  J Clin Exp Dent       Date:  2016-04-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.