Literature DB >> 17320707

Effects of diode laser (810 nm) irradiation on root canal walls: thermographic and morphological studies.

Adriana da Costa Ribeiro1, Gessé Eduardo Calvo Nogueira, João Humberto Antoniazzi, Andreas Moritz, Denise Maria Zezell.   

Abstract

This study investigated the thermal effects and the morphological changes after diode laser irradiation (810 nm) of root canals. Samples were irradiated at 2.5 W, 1,989 W/cm2 (group 2) and 1.25 W, 10 Hz, 994 W/cm2 (group 3), with group 1 being the control group of nonirradiated samples. The temperature rise was evaluated using an infrared thermographic camera, and the morphological changes were assayed by scanning electron microscopy (SEM). The SEM images revealed closed dentinal tubules, especially at the apical regions when compared with the control samples. The maximum temperature variations at the apical region were analyzed, and the resulting 95% confidence intervals of the medians (Wilcoxon) ranged from 1.6 to 8.6 degrees C (group 2) and from 1.2 to 3.3 degrees C (group 3). The results suggest that the diode laser can be used for endodontic purposes and show that the method is safe for periodontal tissues at the investigated parameters.

Mesh:

Year:  2006        PMID: 17320707     DOI: 10.1016/j.joen.2006.09.002

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  9 in total

1.  Comparison of dentin root canal permeability and morphology after irradiation with Nd:YAG, Er:YAG, and diode lasers.

Authors:  Marcella Esteves-Oliveira; Camila A B de Guglielmi; Karen Müller Ramalho; Victor E Arana-Chavez; Carlos Paula de Eduardo
Journal:  Lasers Med Sci       Date:  2010-04-27       Impact factor: 3.161

2.  Evolution of the role of phototherapy during endodontic decontamination.

Authors:  Omid Heidar Muhammad; Jean-Paul Rocca; Carlo Fornaini; Etienne Medioni
Journal:  Laser Ther       Date:  2015-12-30

3.  Effect of Diode Laser on Bacteria Beyond the Apex in Relation to the Size of the Apical Preparation - An In-Vitro Study.

Authors:  Sistla Venkata Jyotsna; Raja Vatsavai Chakradhar Raju; Jaya Prakash Patil; Thakur Veerandar Singh; Neha Bhutani; Shekar Kamishetty; Kiran Ghatole
Journal:  J Clin Diagn Res       Date:  2016-05-01

4.  The effect of the KTP laser on smear layer and temperature change: an in vitro study.

Authors:  Dilara Arslan; Alper Kuştarcı
Journal:  Lasers Med Sci       Date:  2017-11-06       Impact factor: 3.161

5.  Influence of an 810-nm Diode Laser on the Temperature Changes of the External Root Surface: An In Vitro Study.

Authors:  Njwan F Shehab; Nawal A Al-Sabawi; Emad F Alkhalidi
Journal:  J Int Soc Prev Community Dent       Date:  2020-08-06

Review 6.  Clinical Approach of High Technology Techniques for Control and Elimination of Endodontic Microbiota.

Authors:  Nasim Chiniforush; Maryam Pourhajibagher; Sima Shahabi; Abbas Bahador
Journal:  J Lasers Med Sci       Date:  2015-10-27

7.  Effect of a 980-nm diode laser on post-operative pain after endodontic treatment in teeth with apical periodontitis: a randomized clinical trial.

Authors:  Tuna Kaplan; Güzide Pelin Sezgin; Sema Sönmez Kaplan
Journal:  BMC Oral Health       Date:  2021-01-22       Impact factor: 2.757

8.  Comparison of Anti-Bacterial Efficacy between Passive Ultrasonic Irrigation and 980 nm-GaAlAs Laser Application in Two Root Types.

Authors:  Sung-Eun Yang; Yong-Min Kim
Journal:  Medicina (Kaunas)       Date:  2021-05-27       Impact factor: 2.430

9.  Comparison of the Effect of Nd:YAG and Diode Lasers and Photodynamic Therapy on Microleakage of Class V Composite Resin Restorations.

Authors:  Siavash Savadi Oskoee; Parnian Alizadeh Oskoee; Elmira Jafari Navimipour; Amir Ahmad Ajami; Fatemeh Pournaghi Azar; Sahand Rikhtegaran; Melina Amini
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2013-05-30
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.