Fatal inappropriate ICD shock.

Christian Veltmann1, Martin Borggrefe, Rainer Schimpf, Christina Wolpert.   

Abstract

INTRODUCTION: Inappropriate implantable cardioverter defibrillator (ICD) therapy carries a low but relevant risk of ventricular proarrhythmia. In the present case, the extremely rare event of a fatal arrhythmia caused by inappropriate therapy is reported. Dislodgement of the ventricular lead to the level of the tricuspid annulus led to additional sensing of the atrial signal during sinus tachycardia. Spuriously, ventricular fibrillation was sensed and induced inappropriate ICD shocks. The fourth inappropriate shock caused ventricular fibrillation, which was subsequently undersensed by the dislodged lead due to low ventricular amplitudes. The ICD started antibradycardic pacing during ventricular fibrillation. After initial successful resuscitation, the patient died 1 week later due to severe hypoxic brain damage. Although not preventable in the present case, it underlines the necessity of immediate interrogation of the ICD after ICD therapy and deactivation of the ICD in the setting of a dislodged endocardial lead and intensive care monitoring of the patient until revision.

Entities:  

Mesh:

Year:  2007        PMID: 17319001     DOI: 10.1111/j.1540-8167.2006.00692.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  12 in total

1.  DNA fragmentation in leukocytes following subacute low-dose nerve agent exposure.

Authors:  J R Moffett; R A Price; S M Anderson; M L Sipos; A V Moran; F C Tortella; J R Dave
Journal:  Cell Mol Life Sci       Date:  2003-10       Impact factor: 9.261

Review 2.  Inherited primary arrhythmia disorders: cardiac channelopathies and sports activity.

Authors:  S Marrakchi; I Kammoun; E Bennour; L Laroussi; M Ben Miled; S Kachboura
Journal:  Herz       Date:  2018-05-09       Impact factor: 1.443

3.  Sudden cardiac death in the young: how can disease recognition and prevention in family members be improved?

Authors:  Rainer Schimpf; Katrin Yen; Martin Borggrefe
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2012-09

4.  Ineffective ICD Shocks for Ventricular Fibrillation in a Patient with a Left Ventricular Assist Device: Continuous Flow During the Electrical Storm.

Authors:  Enes Elvin Gul; Mohammad Melhem; Sohaib Haseeb; Rifat Al Harach; Osama Al Amudi
Journal:  J Atr Fibrillation       Date:  2018-06-30

5.  A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD) interventions and heart failure hospitalizations in patients with non-ischaemic cardiomyopathy implanted for primary prevention: the RELEVANT [Role of long dEtection window programming in patients with LEft VentriculAr dysfunction, Non-ischemic eTiology in primary prevention treated with a biventricular ICD] study.

Authors:  Maurizio Gasparini; Carlo Menozzi; Alessandro Proclemer; Maurizio Landolina; Severio Iacopino; Angelo Carboni; Ernesto Lombardo; François Regoli; Mauro Biffi; Valeria Burrone; Alessandra Denaro; Giuseppe Boriani
Journal:  Eur Heart J       Date:  2009-06-29       Impact factor: 29.983

6.  Prevention of inappropriate ICD shocks in patients with Brugada syndrome.

Authors:  Christian Veltmann; Juergen Kuschyk; Rainer Schimpf; Florian Streitner; Nina Schoene; Martin Borggrefe; Christian Wolpert
Journal:  Clin Res Cardiol       Date:  2009-09-16       Impact factor: 5.460

Review 7.  Channelopathies: Brugada syndrome, long QT syndrome, short QT syndrome, and CPVT.

Authors:  Rainer Schimpf; Christian Veltmann; Christian Wolpert; Martin Borggrefe
Journal:  Herz       Date:  2009-06       Impact factor: 1.443

8.  Long-time "real-life" performance of the subcutaneous ICD in patients with electrical heart disease or idiopathic ventricular fibrillation.

Authors:  Gerrit Frommeyer; Dirk G Dechering; Simon Kochhäuser; Markus Bettin; Julia Köbe; Lars Eckardt; Florian Reinke
Journal:  J Interv Card Electrophysiol       Date:  2016-05-23       Impact factor: 1.900

9.  Low Prevalence of Inappropriate Shocks in Patients With Inherited Arrhythmia Syndromes With the Subcutaneous Implantable Defibrillator Single Center Experience and Long-Term Follow-Up.

Authors:  Boris Rudic; Erol Tülümen; Veronika Berlin; Susanne Röger; Ksenija Stach; Volker Liebe; Ibrahim El-Battrawy; Christina Dösch; Theano Papavassiliu; Ibrahim Akin; Martin Borggrefe; Jürgen Kuschyk
Journal:  J Am Heart Assoc       Date:  2017-10-17       Impact factor: 5.501

10.  "Atrial torsades de pointes" Induced by Low-Energy Shock From Implantable-Cardioverter Defibrillator.

Authors:  Ilknur Can; Venkatakrishna Tholakanahalli
Journal:  Indian Pacing Electrophysiol J       Date:  2013-09-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.